Abstract
In recent years, newer tools have been developed and used in thyroid surgery. This study compared patients with multinodular goiter undergoing thyroidectomy using the Harmonic FOCUS™ with patients undergoing the clamp-and-tie technique. Medical records of 268 patients with multinodular goiter undergoing thyroidectomy from December 2006 to July 2011 in two centers in Italy, the Department of Surgery of Pisa and the General Surgery Unit of Grosseto, were prospectively evaluated. Patients were divided into group A (Harmonic FOCUS™ Shear), and group B (clamp-and-tie technique). Patient demographics and specific end points analyzed included age, sex, diagnosis, thyroid gland volume, operative time, complications, need for clips and hemostatic agents, need for suction balloon, postoperative blood loss, and postoperative hospital length of stay. 141 patients were included in group A, and 127 patients were included in group B. The two groups were similar in age, sex ratio, indication for surgery, and thyroid volume. Mean operative time was significantly shorter with the Harmonic FOCUS™ Shear (51.8 min) than with the clamp-and-tie technique (70.9 min). The mean postoperative amount obtained from the suction balloon was similar. Vascular clips were needed significantly more frequently in group A (26.2 %) than in group B (12.5 %), whereas the need for hemostatic agents was significantly reduced in group A (4.2 %) compared with group B (14.9 %). The decision to leave a suction drain at the end of the operation occurred significantly more frequently in group B (96 %) than in group A (78 %). Mean postoperative hospital length of stay was 2.02 days in group A compared with 3.1 days in group B, which was significant. No definitive postoperative complications were documented in either group, except a higher rate, but not statistically significant, of permanent hypoparathyroidism in group B versus Group A. Transient laryngeal nerve injury was similar in both groups, whereas transient hypoparathyroidism occurred more frequently in Group B (4.7 %) than in Group A (2.4 %). Harmonic FOCUS device was significantly associated with lower rate of postoperative transient hypocalcemia, decreased operative time, shorter hospitalization, and lesser need for hemostatic agents and postoperative drain balloon. These results might be considered “indirect” money-saving factors, despite the cost of the device, especially in countries where the cost of thyroidectomy is influenced also by the hospital length of stay.
Similar content being viewed by others
References
Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years. World J Surg 28(3):271–276
Becker WF (1977) Pioneers in thyroid surgery. Ann Surg 185(5):493–504
Linos D (2011) Minimally invasive thyroidectomy: a comprehensive appraisal of existing techniques. Surgery 150(1):17–24. Epub 2011 May 18. Review
Lee J, Kang SW, Jung JJ, Choi UJ, Yun JH, Nam KH, Soh EY, Chung WY (2011) Multicenter study of robotic thyroidectomy: short-term postoperative outcomes and surgeon ergonomic considerations. Ann Surg Oncol 18(9):2538–2547
Muenscher A, Dalchow C, Kutta H, Knecht R (2011) The endoscopic approach to the neck: a review of the literature, and overview of the various techniques. Surg Endosc 25(5):1358–63. Epub 2010 Dec 7. Review
Miccoli P, Materazzi G. Minimally invasive, video-assisted thyroidectomy (MIVAT) Surg Clin North Am. 2004 Jun;84(3):735-41
Dionigi G, Boni L, Rausei S, Frattini F, Ferrari CC, Mangano A, Leotta A, Franchin M (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS. Langenbecks Arch Surg. (Epub ahead of print)
Manouras A, Markogiannakis H, Koutras AS et al (2008) Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 195(1):48–52
Shen WT, Baumbusch MA, Kebebew E, Duh QY (2005) Use of the electrothermal vessel sealing system versus standard vessel ligation in thyroidectomy. Asian J Surg 28(2):86–89
Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740
Kilic M, Keskek M, Ertan T, Yoldas O, Bilgin A, Koc M (2007) A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 24(3):632–638
Prgomet D, Janjanin S, Bilić M et al (2009) A prospective observational study of 363 cases operated with three different harmonic scalpels. Eur Arch Otorhinolaryngol 266(12):1965–1970
Mourad M, Rulli F, Robert A, Scholtes JL, De Meyer M, De Pauw L (2011) Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy. Am J Surg 202(2):168–174
Ferri E, Armato E, Spinato G, Spinato R (2011) Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial. Int J Otolaryngol 2011:357195. (Epub 2011 Sep 29)
Sebag F, Fortanier C et al (2009) Harmonic scalpel in multinodular goiter surgery: impact on surgery and cost analysis. J Laparoendosc Adv Surg Tech A 19(2):171–174
Lombardi CP, Raffaelli M et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393(5):627–631
Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the Ultracision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14(1):9–12
Fujita T, Doihara H, Ogasawara Y, Shimizu N (2006) Utility of vessel-sealing systems in thyroid surgery. Acta Med Okayama 60:93–98
Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29:771–774
Kiriakopoulos A, Dimitrios T, Dimitrios L (2004) Use of a diathermy system in thyroid surgery. Arch Surg 139:997–1000
Lachanas VA, Prokopakis EP, Mpenakis AA et al (2005) The use of ligasure vessel sealing system in thyroid surgery. Otolaryngol Head Neck Surg 132:487–489
Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231:322–328
Pardal-Refoyo JL (2011) Hemostatic systems in thyroid surgery and complications Acta Otorhinolaringol Esp 62(5):339–46. (Epub 2011 May 6)
Defechereux T, Rinken F, Maweja S, Hamoir E, Meurisse M (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277
Miccoli P, Berti P, Dionigi GL, D’Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073
Cordón C, Fajardo R, Ramírez J, Herrera MF (2005) A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy. Surgery 137(3):337–341
He Q, Zhuang D, Zheng L, Zhou P, Chai J, Lv Z (2011) Harmonic focus in total thyroidectomy plus level III–IV and VI dissection: a prospective randomized study. World J Surg Oncol 31(9):141
Markogiannakis H, Kekis PB, Memos N, Alevizos L, Tsamis D, Michalopoulos NV (2011) Thyroid surgery with the new harmonic scalpel: a prospective randomized study. Surgery 149:411–415
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Materazzi, G., Caravaglios, G., Matteucci, V. et al. The impact of the Harmonic FOCUS™ on complications in thyroid surgery: a prospective multicenter study. Updates Surg 65, 295–299 (2013). https://doi.org/10.1007/s13304-013-0223-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13304-013-0223-2