Skip to main content
Log in

Experimental and Numerical Assessment of Reduced IPE Beam Sections Connections with Box-Stiffener

  • Published:
International Journal of Steel Structures Aims and scope Submit manuscript

Abstract

Reduced Beam Section (RBS) is a new type of connection in steel moment resistant frames that was introduced after the Northridge earthquake of 1994. The application of RBS connections associated with reduced beam flange width can aid in accelerating web, flange, and lateral-torsional bucklings in the beam. To fix this problem, a new type of stiffener called the box-stiffener was presented in this study, which exactly encases the reduced portion of the beam. First, 4 laboratory tests were performed on RBS connections made of IPE140 and IPE270 sections in the two conditions of ‘with’ and ‘without’ a boxstiffener. Laboratory results showed that the stiffener considerably enhanced the connection ductility without a significant increase in the connection’s resistance. To examine other sizes of IPE sections, a verified Finite Element model was utilized. The results of the numerical models also confirmed the suitable performance of the box-stiffener.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • American Institute of Steel Construction (AISC). Seismic provisions for structural steel buildings, ANSI/AISC 341-10, Chicago; 2010.

  • American Institute of Steel Construction (ANSI/AISC 358-05). Prequalified connections for special and intermediate steel moment frames for seismic applications, Chicago; 2006.

    Google Scholar 

  • American Society for Testing and Materials (ASTM). Standard test methods and definitions for mechanical testing of steel products, ASTM Standard A370-02, Philadelphia, PA; 2002.

    Google Scholar 

  • Atashzaban A., Hajirasouliha I., Jazany R. A., Izadinia M. (2015). “Optimum drilled flange moment resisting connections for seismic regions.” Journal of Constructional Steel Research, 112, pp. 325–338.

    Article  Google Scholar 

  • Chi WM, El-Tawil S, Deierlein GG, Abel JF.(1998). “Inelastic analyses of a 17-story steel framed building damaged during Northridge.” Engineering Structures, 20(4), pp. 481–495.

    Article  Google Scholar 

  • Deylami A, Moslehi Tabar A. (2013). “Promotion of cyclic behavior of reduced beam section connections restraining beam web to local buckling.” Thin-Walled Structures, 73, pp. 112–120.

    Article  Google Scholar 

  • FEMA. Prestandard and commentary for the seismic rehabilitation of buildings. Report FEMA356, Federal Emergency Management Agency, Washington DC: USA; 2000.

    Google Scholar 

  • Han SW, Moon KH, Hwang SH, Stojadinovic B. (2012). “Rotation capacities of reduced beam section with bolted web (RBS-B) connections.” Journal of Constructional Steel Research, 70, pp. 256–263.

    Article  Google Scholar 

  • Han, Sang-Whan, Ki-Hoon Moon, and Bozidar Stojadinovic. (2009). “Design equations for moment strength of RBSB connections.” Journal of Constructional Steel Research, 65.5, pp. 1087–1095.

    Article  Google Scholar 

  • Lee C. H., Jung J.H., Kim S. Y., Kim J. J. (2016). “Review of composite slab effect on seismic performance of welded steel moment connections.” Journal of Constructional Steel Research, 117, pp. 91–100.

    Article  Google Scholar 

  • Mirghaderi SR, Torabian S, Imanpour A. (2010). “Seismic performance of the Accordion-Web RBS connection.” Journal of Constructional Steel Research, 66(2), pp. 277–288.

    Article  Google Scholar 

  • Pachoumis DT, Galoussis EG, Kalfas CN, Christitsas AD.(2009). “Reduced beam section moment connections subjected to cyclic loading: Experimental analysis and FEM simulation.” Engineering Structures, 31(1), pp. 216–223.

    Article  Google Scholar 

  • Pachoumis DT, Galoussis EG, Kalfas CN, Efthimiou IZ.(2010). “Cyclic performance of steel moment-resisting connections with reduced beam sections-experimental analysis and finite element model simulation.” Engineering Structures, 32(9), pp. 2683–26926.

    Article  Google Scholar 

  • Righiniotis TD, Imam B. (2004). “Fracture reliability of a typical Northridge steel moment resisting connection.” Engineering structures, 26(3), pp. 381–390.

    Article  Google Scholar 

  • Saleh, Aboozar, Seyed Rasoul Mirghaderi, and Seyed Mehdi Zahrai. (2016). “Cyclic testing of tubular web RBS connections in deep beams.” Journal of Constructional Steel Research, 117, pp. 214–226.

    Article  Google Scholar 

  • Shi G, Wang M, Bai Y, Wang F, Shi YJ, Wang YQ.(2012). “Experimental and modeling study of high-strength structural steel under cyclic loading.” Engineering Structures, 37, pp. 1–13.

    Article  Google Scholar 

  • Tahamouli Roudsari M, Abdollahi F, Salimi H, Azizi S, and Khosravi AR.(2015). “The Effect of Stiffener on Behavior of Reduced Beam Section Connections in Steel Moment-Resisting Frames.” International Journal of Steel Structures, 15(4), pp. 827–834.

    Article  Google Scholar 

  • Wilkinson, Sean, Gordon Hurdman, and Adrian Crowther. (2006). “A moment resisting connection for earthquake resistant structures.” Journal of Constructional Steel Research, 62.3, pp. 295–302.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Tahamouli Roudsari.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Roudsari, M.T., Jamshidi K., H. & Moradi, S.H. Experimental and Numerical Assessment of Reduced IPE Beam Sections Connections with Box-Stiffener. Int J Steel Struct 18, 255–263 (2018). https://doi.org/10.1007/s13296-018-0319-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13296-018-0319-0

Keywords

Navigation