Abstract
Following the 1994 Northridge earthquake, reduced beam section (RBS) was presented as a novel connection detail in the steel moment-resisting frames. Proposed detail aims to debilitate the beam at a limited interval from the connection so that less moment and force are assigned to the connection. Cutting of the beam flange, especially in the narrow sections such as IPE, leads to an increase in the potential for the web local buckling, beam lateral-torsional buckling, and reduction in the beam strength. The hysteresis curve of IPE profiles, particularly in medium and large sections, is highly declining after the buckling. In this paper, a simple method was presented to amend the efficiency of IPE beams with an arched cutting in the flange, using horizontal and vertical stiffeners of the beam web. The experimental results and those of finite element in IPE beams revealed that the simultaneous application of horizontal and vertical stiffeners of the beam web largely prevented the declining of the beam hysteresis curve and left a full effect on its behavior. Therefore, the use of these types of connections in seismic areas with high relative risks is recommended.
Similar content being viewed by others
References
American Institute of Steel Construction, AISC. (2010). Seismic provisions for structural steel buildings, ANSI/AISC 341–10, Chicago.
American Institute of Steel Construction, ANSI/AISC 358–05. (2006). Prequalified connections for special and intermediate steel moment frames for seismic applications, Chicago.
American Society for Testing and Materials, ASTM. (2002). Standard test methods and definitions for mechanical testing of steel products, ASTM Standard A370-02, Philadelphia, PA.
Atashzaban, A., Hajirasouliha, I., Jazany, R. A., & Izadinia, M. (2015). Optimum drilled flange moment resisting connections for seismic regions. Journal of Constructional Steel Research,112, 325–338.
Chi, W. M., El-Tawil, S., Deierlein, G. G., & Abel, J. F. (1998). Inelastic analyses of a 17-story steel framed building damaged during Northridge. Engineering Structures,20(4), 481–495.
Deylami, A., & MoslehiTabar, A. (2013). Promotion of cyclic behavior of reduced beam section connections restraining beam web to local buckling. Thin-Walled Structures,73, 112–120.
FEMA. (2000). Prestandard and commentary for the seismic rehabilitation of buildings. Report FEMA356. Washington DC: Federal Emergency Management Agency.
FEMA. (2005). Improvement of nonlinear static seismic analysis procedures FEMA-440. Redwood City: Federal Emergency Management Agency.
Han, S. W., Moon, K. H., Hwang, S. H., & Stojadinovic, B. (2012). Rotation capacities of reduced beam section with bolted web (RBS-B) connections. Journal of Constructional Steel Research,70, 256–263.
International Organization for Standardization, ISO. (2009). ISO 898-1, mechanical properties of fastenersmade of carbon steel and alloy steel —Part 1: bolts, screws and studs with pecified property classes—coarse thread and fine pitch thread. Geneva, Switzerland.
Maleki, S., & Tabbakhha, M. (2012). Numerical study of slotted-web–reduced-flange moment connection. Journal of Constructional Steel Research,69(1), 1–7.
Mirghaderi, S. R., Torabian, S., & Imanpour, A. (2010). Seismic performance of the Accordion-Web RBS connection. Journal of Constructional Steel Research,66(2), 277–288.
Morrison, M., Schweizer, D., & Hassan, T. (2015). An innovative seismic performance enhancement technique for steel building moment resisting connections. Journal of Constructional Steel Research,109, 34–46.
Naghipour, M., Javadi, N., & Naghipour, A. (2011). Investigation of RBS connection ductility in eccentrically braced frame. Procedia Engineering,14, 743–752.
Ohsaki, M., Tagawa, H., & Pan, P. (2009). Shape optimization of reduced beam section under cyclic loads. Journal of Constructional Steel Research,65(7), 1511–1519.
Pachoumis, D. T., Galoussis, E. G., Kalfas, C. N., & Christitsas, A. D. (2009). Reduced beam section moment connections subjected to cyclic loading: Experimental analysis and FEM simulation. Engineering Structures,31(1), 216–223.
Pachoumis, D. T., Galoussis, E. G., Kalfas, C. N., & Efthimiou, I. Z. (2010). Cyclic performance of steel moment-resisting connections with reduced beam sections—experimental analysis and finite element model simulation. Engineering Structures,32(9), 2683–26926.
Righiniotis, T. D., & Imam, B. (2004). Fracture reliability of a typical Northridge steel moment resisting connection. Engineering Structures,26(3), 381–390.
Shi, G., Wang, M., Bai, Y., Wang, F., Shi, Y. J., & Wang, Y. Q. (2012). Experimental and modeling study of high-strength structural steel under cyclic loading. Engineering Structures,37, 1–13.
Tahamouli Roudsari, M., Jamshidi, K. H., & Mohebi Zangeneh, M. (2018). Experimental and numerical investigation of IPE reduced beam sections with diagonal web stiffeners. Journal of Earthquake Engineering, 22(4), 533–552.
Acknowledgements
The authors would like to extend their gratitude to the structural research lab of the Islamic Azad University of Kermanshah.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
On behalf of all the authors, the corresponding author states that there is no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Tahamouli Roudsari, M., Jamshidi K., H., Akbari G., F. et al. An experimental and numerical investigation of reduced beam section connections with horizontal and vertical web stiffeners. Asian J Civ Eng 21, 581–595 (2020). https://doi.org/10.1007/s42107-019-00214-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s42107-019-00214-1