Abstract
In steel moment frames, columns are subjected to unbalance moment that is transmitted into the joint through a couple of concentrated forces at the centroid of the beam’s flanges. If the flexural capacity of the column flange is less than produced moment by these tensile or compressive forces, use of continuity plates in the panel zone is necessary. Since in box-shaped column, welding the forth edge of a continuity plate to the column flange may not be easily done and is usually accompanied by remarkable difficulties, double-web H-shaped columns as an appropriate alternative, which often do not require continuity plates, can be used. Numerous studies are carried out on local flange bending in H–shaped columns and are referred in the valid guidelines. The behavior of double-web column’s flange is between box shaped and H-shaped column’s flange. This paper presents analytical and numerical modeling of double web column to estimate local flange bending. The numerical modeling is derived from the results of finite element analyses. Based on these two approaches, some equations are presented to estimate local flange bending of double web columns, and are shown their efficiency and accuracy.
Similar content being viewed by others
References
ABAQUS CAE, (2012). “ABAQUS user manual.” ABAQUS, Inc.
AISC (2010). “Specification for structural steel buildings.” American Institute of Steel Construction, ANSI/AISC 361-10, Chicago.
AISC (2010). “Seismic Provisions for Structural Steel Buildings.” American Institute of Steel Construction, ANSI/AISC 341-10, Chicago.
El-Tawil, S., Mikesell, T., Vidarsson, E. and Kunnath, S. (1998). “Strength and ductility of FRwelded-bolted connections.” Report No. SAC/BD-98/01, Applied Technology Council, Redwood City, California.
Engelhard, M.D. and Sabol, T.A. (1998). “Reinforcing of steel moment connections with cover plates: benefits and limitations.” Engineering Structures, 20(4), pp. 510–520.
Engelhardt, M. D. (1999). “Design of reduced beam section moment connections.” AISC North American Steel Construction Conference, Toronto, Ontario, May 19-21.
FEMA, (2000). “Recommended Seismic Design Criteria for New Moment-Resisting Steel Frame Structures.” Report No. FEMA 350, SAC Joint Venture, Sacramento, California.
Graham, J. D., Sherbourne, A. N., Khabbaz, R. N. and Jensen, C. D. (1960). “Welded interior beam-to-column connections.” Welding Research Council, Bulletin No. 63, pp. 1-28.
Hedayat, A.A., Saffari, H. and Jazebi, E. (2016). “Investigation of the effective parameters on the strength and ductility of the welded flange plate connections.” Asian Journal of Civil Engineering (BHRC), 17(1), pp. 15–42.
Hedayat, A.A., Saffari, H. and Hadi, A. (2016). “Ductility of post-Northridge connections with Angelina beams.” Proceedings of the Institution of Civil Engineers: Structures and Buildings, 169(3), pp. 184–209.
Hedayat, A.A., Saffari, H. and Mousavi, M. (2013). “Behavior of steel reduced beam web (RBW) connections with arch-shape cut.” Advances in Structural Engineering, 16 (10), pp. 1645–1662.
Hu, Z. and Xue, J. (2016). “Analysis on the shear capacity of irregular joints between steel box columns and beams.” International Journal of Steel Structures, 16(2), pp. 517–530.
Johnson, L.G. (1959a). “Tests on welded connections between I-section beams and stanchions.” British Welding Journal, 6(1), pp. 38–46.
Johnson, L.G. (1959b). “Further tests on welded connections between I-section beams and stanchions.” British Welding Journal, 6(1), pp. 367–373.
Johnson, L.G. (1959c). “Compressive and tensile loading tests on joists with web stiffeners.” British Welding Journal, 6(1), pp. 411–420.
Kim, SY., Shin, KJ., Lee, SH. and Lee, HD. 2016. “Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading.” International Journal of Steel Structures, 16(4) pp. 1299–1307.
Kim, T., Whittaker, A., Gilani, A., Bertero, V. and Takhirov, S. (2002). “Cover-plate and flange-plate steel momentresisting connections.” J. Struct. Eng. 128, Special Issue: Steel Moment Frames After Northridge-part II, pp. 474–482.
Lee, K.H., Stojadinovic, B., Goel, S.C., Margarin, A.G., Choi, J., Wongkaew, A., Reyher, B.P. and Lee, D.Y. (2000). “Parametric tests on unreinforced connections.” SAC Background Document, SAC/BD-00/01, SAC Joint Venture, Richmond, CA.
Mansouri, I. and Saffari, H. (2014). “A new steel panel zone model including axial force for thin to thick column flanges.” Steel and Composite Structures, 16(4), pp. 417–436.
Oh, K., Li, R., Chen, L., Hong, S. B. and Lee, K. (2014). “Cyclic testing of steel moment connections with weakened beam splices.” International Journal of Steel Structures, 14(3), pp. 471–478.
Popov, E.P., Yang, T.S. and Chang, S.P. (1998). “Design of steel MRF connections before and after 1994 Northridge earthquake.” Engineering Structures, 20(12), pp. 1030–1038.
Popov, E. P., Amin, N. R., Louie, J. J. C. and Stephen, R. M. (1986). “Cyclic behavior of large beam-column assemblies.” Engineering Journal, AISC, 23(1), pp. 9–23.
Prochnow, S.D., Ye, Y., Dexter, R.J., Hajjar, J.F. and Cotton, S.C. (2000). “Local flange bending and local web yielding limit states in steel moment resisting connections.” Connections in Steel Structures IV Behavior, Strength and Design, R.T. Leon and W.S. Easterling (eds.), AISC, Chicago, IL, pp. 318–328.
Ricles, J. M., Mao, L., Kaufmann, E. J., Lu, L., and Fisher, J. W. (2000). “Development and evaluation of improved details for ductile welded unreinforced flange connections.” SAC BD00-24, SAC Joint Venture, Sacramento, California.
Roeder, C. W. (1997). “An evaluation of cracking observed in steel moment frames.” Proceedings of the ASCE Structures Congress, Kempner, L., Brown, C. (eds.), Portland, Oregon, April 13-16, 1997, ASCE, New York, pp. 767–771.
Saffari, H., Hedayat, A. A. and Soltani, N. (2015). “New alternates for continuity plates in I-beam to box columns connections.” Asian Journal of Civil Engineering (BHRC), 16(2), pp. 219–233.
Saffari, H., Hedayat, A.A. and Nejad, M. P. (2013). “Post-Northridge connections with slit dampers to enhance strength and ductility.” Journal of Constructional Steel Research, 80, pp. 138–152.
Saffari, H., Hedayat, A.A. and Soltani, N. (2013). “Suggesting double-web I-shape columns for omitting continuity plates in a box column.” Steel and Composite Structures, 15(6), pp. 585–603.
Saffari, H., Sarfarazi, S. and Fakhraddini, A. (2016). “A mathematical steel panel zone model for flanged cruciform columns.” Steel and Composite Structures, 20(4), pp. 851–867.
Sherbourne, A. N. and Jensen, C. D. (1957). “Direct Welded Beam Column Connections.” Report. No. 233.12, Fritz Laboratory, Lehigh University, Bethlehem, Pennsylvania.
Tremblay, R., Timler, P., Bruneau, M. and Filiatrault, A. (1995). “Performance of Steel Structures during the 1994 Northridge Earthquake.” Canadian Journal of Civil Engineering, 22, pp. 338–360.
Wang, Y., Zhou, H., Shi, Y. and Hong, C. (2010). “Fracture behavior analyses of welded beam-to-column connections based on elastic and inelastic fracture mechanics.” International Journal of Steel Structures, 10(3), pp. 253–265.
Wood, R. H. (1955). “Yield line theory.” Research Paper No. 22, Building Research Station.
Yee, R. K., Paterson, S. R. and Egan, G. R. (1998). “Engineering evaluations of column continuity plate detail design and welding issues in welded steel moment frame connections.” Welding for Seismic Zones in New Zealand, Aptech Engineering Services, Inc., Sunnyvale, California.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Amani, R., Saffari, H. & Fakhraddini, A. Local Flange Bending and Continuity Plate Requirements in Double-Web H-Shaped Columns. Int J Steel Struct 18, 199–209 (2018). https://doi.org/10.1007/s13296-018-0316-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13296-018-0316-3