Abstract
The national diagnostic reference level service (NDRLS), was launched in 2011, however no paediatric data were submitted during the first calendar year of operation. As such, Australian national diagnostic reference levels (DRLs), for paediatric multi detector computed tomography (MDCT), were established using data obtained from a Royal Australian and New Zealand College of Radiologists (RANZCR), Quality Use of Diagnostic Imaging (QUDI), study. Paediatric data were submitted to the NDRLS in 2012 through 2015. An analysis has been made of the NDRLS paediatric data using the same method as was used to analyse the QUDI data to establish the Australian national paediatric DRLs for MDCT. An analysis of the paediatric NDRLS data has also been made using the method used to calculate the Australian national adult DRLs for MDCT. A comparison between the QUDI data and subsequent NDRLS data shows the NDRLS data to be lower on average for the Head and AbdoPelvis protocol and similar for the chest protocol. Using an average of NDRLS data submitted between 2012 and 2015 implications for updated paediatric DRLS are considered.
Similar content being viewed by others
References
Lee C, Pearce MS, Salotti JA et al (2016) Reduction in radiation doses from paediatric CT scans in Great Britain. Br J Radiol 89(1060):20150305. doi:10.1259/bjr.20150305
Wallace AB (2010) The implementation of diagnostic reference levels to Australian radiology practice. J Med Imaging Radiat Oncol 54(5):465–471. doi:10.1111/j.1754-9485.2010.02198.x
Hayton A, Wallace A, Marks P et al (2013) Australian per caput dose from diagnostic imaging and nuclear medicine. Radiat Prot Dosimetry. doi:10.1093/rpd/nct101
ARPANSA (2016) Introducing the national diagnostic reference level service. http://www.arpansa.gov.au/services/ndrl/index.cfm
ARPANSA (2014) Current Australian national diagnostic reference levels for MDCT. http://www.arpansa.gov.au/services/ndrl/current.cfm
Hayton A, Wallace A, Marks P et al (2013) Australian diagnostic reference levels for multi detector computed tomography. Australas Phys Eng Sci Med 36(1):19–26. doi:10.1007/s13246-013-0180-6
ICRP ICRP Publication 73 (1996) Radiological protection and safety in medicine. Ann ICRP 26(2):1–47
ARPANSA (2016) Before you enter data. http://www.arpansa.gov.au/Services/NDRL/beforeData.cfm
Australian government DoHS. Medicare benefits Schedule. http://www.medicareaustralia.gov.au/provider/medicare/mbs.jsp#N10030
Hayton A, Wallace A (2016) Derivation of Australian diagnostic reference levels for paediatric multi detector computed tomography. Australas Phys Eng Sci Med. doi:10.1007/s13246-016-0431-4
WHO Child growth standards (2014) http://www.who.int/childgrowth/en/
Conover WJ (1971) Practical nonparametric statistics. Wiley, New York
Vassileva J, Rehani M, Kostova-Lefterova D et al (2015) A study to establish international diagnostic reference levels for paediatric computed tomography. Radiat Prot Dosimetry. doi:10.1093/rpd/ncv116
Acknowledgements
The authors would like to thank every facility that has utilised the NDRLS to date.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants performed by any of the authors.
Rights and permissions
About this article
Cite this article
Anna, H., Wallace, A. & Thomas, P. Validation of the Australian diagnostic reference levels for paediatric multi detector computed tomography: a comparison of RANZCR QUDI data and subsequent NDRLS data from 2012 to 2015. Australas Phys Eng Sci Med 40, 101–114 (2017). https://doi.org/10.1007/s13246-016-0508-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-016-0508-0