Abstract
We aimed to evaluate the interference of 50 Hz extremely low frequency electromagnetic field (ELF-EMF) occupational exposure on the neurobehavior tests of workers performing tour-inspection close to transformers and distribution power lines. Occupational short-term “spot” measurements were carried out. 310 inspection workers and 300 logistics staff were selected as exposure and control. The neurobehavior tests were performed through computer-based neurobehavior evaluation system, including mental arithmetic, curve coincide, simple visual reaction time, visual retention, auditory digit span and pursuit aiming. In 500 kV areas electric field intensity at 71.98 % of total measured 590 spots were above 5 kV/m (national occupational standard), while in 220 kV areas electric field intensity at 15.69 % of total 701 spots were above 5 kV/m. Magnetic field flux density at all the spots was below 1,000 μT (ICNIRP occupational standard). The neurobehavior score changes showed no statistical significance. Results of neurobehavior tests among different age, seniority groups showed no significant changes. Neurobehavior changes caused by daily repeated ELF-EMF exposure were not observed in the current study.
Similar content being viewed by others
References
McNamee DA, Legros AG, Krewski DR, Wisenberg G, Prato FS, Thomas AW (2009) A literature review: the cardiovascular effects of exposure to extremely low frequency electromagnetic fields. Int Arch Occup Environ Health 82:919–933
Corbacio M, Brown S, Dubois S, Goulet D, Prato FS, Thomas AW, Legros A (2011) Human cognitive performance in a 3 mT power-line frequency magnetic field. Bioelectromagnetics 32:620–633
Podd J, Abbott J, Rowland A, Kazantzis N (2002) Brief exposure to a 50 Hz, 100 μT magnetic field: effects on reaction time, accuracy, and recognition memory. Bioelectromagnetics 23:189–195
Legros A, Beuter A (2005) Effect of a low intensity magnetic field on human motor behavior. Bioelectromagnetics 26:657–669
Legros A, Corbacio M, Beuter A, Modolo J, Goulet D, Prato FS, Thomas AW (2012) Neurophysiological and behavioral effects of a 60 Hz, 1800 μT magnetic field in humans. Eur J Appl Physiol 112:1751–1762
Keetley V, Wood A, Sadafi H, Stough C (2001) Neuropsychological sequelae of 50 Hz magnetic fields. Int J Radiat Biol 77:735–742
Preece AW, Wesnes KA, Iwi GR (1998) The effect of a 50 Hz magnetic field on cognitive function in humans. Int J Radiat Biol 74:463–470
Kazantzis N, Podd J, Whittington C (1996) Acute effects of 50 Hz, 100 μT magnetic field exposure on visual duration discrimination at two different times of the day. Bioelectromagnetics 19:310–317
Legros A, Gaillot P, Beuter A (2006) Transient effect of low-intensity magnetic field on human motor control. Med Eng Phys 28:827–836
Legros A, Beuter A (2006) Individual subject sensitivity to extremely low frequency magnetic field. Neurotoxicology 27:534–546
Nevelsteen S, Legros JJ, Crasson M (2007) Effects of information and 50 Hz magnetic fields on cognitive performance and reported symptoms. Bioelectromagnetics 28:53–63
Delhez M, Legros JJ, Crasson M (2004) No influence of 20 and 400 μT, 50 Hz magnetic field exposure on cognitive function in humans. Bioelectromagnetics 25:592–598
Cook MR, Graham C, Cohen HD, Gerkovich MM (1992) A replication study of human exposure to 60 Hz fields: effects on Neurobehavior measures. Bioelectromagnetics 13:261–285
Cook CM, Thomas AW, Prato FS (2002) Human electrophysiological and cognitive effects of exposure to ELF magnetic and ELF modulated RF and microwave fields: a review of recent studies. Bioelectromagnetics 23:144–157
Frahm J, Mattsson MO, Simkó M (2010) Exposure to ELF magnetic field modulate redox related protein expression in mouse macrophages. Toxicol Lett 192:330–336
Türközer Z, Güler G, Seyhan N (2008) Effects of exposure to 50 Hz electric field at different strengths on oxidative stress and antioxidant enzyme activities in the brain tissue of guinea pigs. Int J Radiat Biol 84:581–590
Rageh MM, El-Gebaly RH, El-Bialy NS (2012) Assessment of genotoxic and cytotoxic hazards in brain and bone marrow cells of newborn rats exposed to extremely low-frequency magnetic field. J Biomed Biotechnol 2012:716023
Anger WK, Liang YX, Nell V, Kang SK, Cole D, Bazylewicz-Walczak B, Rohlman DS, Sizemore OJ (2000) Lessons learned—15 years of the WHO-NCTB: a review. Neurotoxicology 21:837–846
Gauger JR (1985) Household appliance magnetic field survey. IEEE Trans Power Appar Syst PAS 104:2436–2444
Gandhi OP, Kang G, Wu D, Lazzi G (2001) Currents induced in anatomic models of the human for uniform and nonuniform power frequency magnetic fields. Bioelectromagnetics 22:112–121
Nishimura T, Tada H, Guo X, Murayama T, Teramukai S, Okano H, Yamada J, Mohri K, Fukushima M (2011) A 1-μT extremely low-frequency electromagnetic field vs. sham control for mild-to-moderate hypertension: a double-blind, randomized study. Hypertens Res 34:372–377
Crasson M (2003) 50–60 Hz electric and magnetic field effects on cognitive function in humans: a review. In: Weak ELF electric field effects in the body. Proceedings of an International Workshop, Chilton, National Radiological Protection Board, March 2003. Radiat Prot Dosimetry 106:333–340
Trimmel M, Schweiger E (1998) Effects of an ELF (50 Hz, 1 mT) electromagnetic field (EMF) on concentration in visual attention, perception and memory including effects of EMF sensitivity. Toxicol Lett 96–97:377–382
Rubin GJ, Hillert L, Nieto-Hernandez R, van Rongen E, Oftedal G (2011) Do people with idiopathic environmental intolerance attributed to electromagnetic field display physiological effects when exposed to electromagnetic field? A systematic review of provocation studies. Bioelectromagnetics 32:593–609
Szemerszky R, Köteles F, Lihi R, Bárdos G (2010) Polluted places or polluted minds? An experimental sham-exposure study on background psychological factors of symptom formation in ‘Idiopathic Environmental Intolerance attributed to electromagnetic field’. Int J Hyg Environ Health 213:387–394
Liu X, Zhao L, Yu D, Ma S, Liu X (2013) Effects of extremely low frequency electromagnetic field on the health of workers in automotive industry. Electromagn Biol Med 32(4):551–559
Thuróczy G, Jánossy G, Nagy N, Bakos J, Szabó J, Mezei G (2008) Exposure to 50 Hz magnetic field in apartment buildings with built-in transformer stations in Hungary. Radiat Prot Dosimetry 131(4):469–473
Valjus J, Hongisto M, Verkasalo P, Järvinen P, Heikkilä K, Koskenvuo M (1995) Residential exposure to magnetic fields generated by 110–400 kV power lines in Finland. Bioelectromagnetics 16(6):365–376
Hareuveny R, Kandel S, Yitzhak NM, Kheifets L, Mezei G (2011) Exposure to 50 Hz magnetic fields in apartment buildings with indoor transformer stations in Israel. J Expo Sci Environ Epidemiol 21(4):365–371
Ztoupis IN, Gonos IF, Stathopulos IA (2013) Uncertainty evaluation in the measurement of power frequency electric and magnetic fields from AC overhead power lines. Radiat Prot Dosimetry 157(1):11–21
Di Loreto S, Falone S, Caracciolo V, Sebastiani P, D’Alessandro A, Mirabilio A, Zimmitti V, Amicarelli F (2009) Fifty hertz extremely low-frequency magnetic field exposure elicits redox and trophic response in rat-cortical neurons. J Cell Physiol 219:334–343
da Cruz MT, Cardoso AL, de Almeida LP, Simões S, de Lima MC (2005) Tf-lipoplex-mediated NGF gene transfer to the CNS: neuronal protection and recovery in an excitotoxic model of brain injury. Gene Ther 12:1242–1252
Saunders RD, Jefferys JG (2007) A neurobiological basis for ELF guidelines. Health Phys 92:596–603
Hodgkin AL, Huxley AF (1952) A quantitative description of membrane current and its application to conduction and excitation in nerve. J Physiol 117:500–544
Z’Graggen WJ, Bostock H (2008) Nerve membrane excitability testing. Eur J Anaesthesiol Suppl 42:68–72
Acknowledgments
This work was supported by the Guangdong Power Grid Corporation, Guangzhou, China.
Conflict of interest
The authors declare they have no competing financial interests.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Li, L., Xiong, Df., Liu, Jw. et al. No effects of power line frequency extremely low frequency electromagnetic field exposure on selected neurobehavior tests of workers inspecting transformers and distribution line stations versus controls. Australas Phys Eng Sci Med 37, 37–44 (2014). https://doi.org/10.1007/s13246-013-0237-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-013-0237-6