Introduction

Glucose metabolism is a central cellular function and elevated glucose levels beyond 5.5 mM in blood and low or high uptake of glucose by the cell results in several disorders. Proper monitoring of glucose levels will help to reduce the risk of diabetes, atherosclerosis, diabetic retinopathy, kidney failure, nerve degeneration, etc. (Zhu et al. 2012). Elevated glucose levels have become a major clinical parameter for the diagnosis of diabetes and it is also used to decide the dosage of insulin to patients. Glucose has also been identified as a critical component in the pro-inflammatory response of macrophages (Freemerman et al. 2014). Macrophages are key components of our cellular immunity and play a major role in the deposition of plaques in arteries leading to atherosclerosis. Macrophages react with low-density lipoproteins and create foam cells, which in turn disintegrate to form crystal-like cholesterol structures. The cholesterol crystals activate new macrophages causing them to release inflammatory cytokines and amplify inflammation (Maltby et al. 2009; Numata et al. 2016). Hence, quantification of glucose levels in macrophages in normal and stimulated conditions can be an ideal system to predict the risk of macrophage-assisted atherosclerosis. Furthermore, it can also be an indispensable clinical parameter for the diagnosis of diabetes and atherosclerosis risk and also help in the design of appropriate treatment regimen. Such strategy has not been explored thoroughly in the realm of healthcare sensors and has been attempted for the first time in the present work.

In the context of rapid diagnosis, electrochemical sensors have gained popularity due to their low cost, easy preparation, sensitivity, rapid response, and simple operation that enables self monitoring by an individual (Wang et al. 2008b; Harper and Anderson 2010; Kimmel et al. 2013). The sensing element widely employed in electrochemical glucose sensors is glucose oxidase enzyme immobilized on the electrode surface. Most of the commercially available glucometers are enzyme-based because of the high sensitivity and good selectivity of the enzyme towards the analyte (Wang et al. 2011; Chen et al. 2012; Zhang et al. 2014). The first-generation glucose sensors monitored oxygen content at the electrode, while the second-generation sensors used a redox mediator to measure the signal. The third-generation sensors utilized direct electron transfer at the electrode surface to measure the current. However, the electron transfer between the immobilized enzyme and the electrode surface was slow. This prompted the development of nano-structured interfaces that facilitated rapid electron transfer. However, enzymatic sensors are limited (Wang et al. 2008a) by their instability due to changes in temperature and pH (Park et al. 2006; Wang et al. 2013; Li et al. 2015). This has led to the development of the fourth generation of electrochemical sensors that are enzyme-free. The catalysis is brought about by nanodimensional particles at the electrode surface. The nano-interface possesses high surface area-to-volume ratio, fast and direct electron transfer, desirable electrical and mechanical properties, as well as the capability of adsorbing biomolecules (Dong and Chen 2002; Asefa et al. 2009). A majority of non-enzymatic sensors have employed metallic nanoparticles such as platinum (Yuan et al. 2005; Cao et al. 2007), gold (Ma et al. 2009), nickel (Salimi et al. 2004; Sue et al. 2008), copper (Sattayasamitsathit et al. 2009; Chen et al. 2012), bimetallic systems such as Pt–Pb and metal oxides such as CuO (Reitz et al. 2008; Wang et al. 2010), ZnO (Lei et al. 2010), TiO2 (Lo et al. 2008) alone or in combination with carbon nanostructures such as single-walled (Su et al. 2010) and multi-walled carbon nanotubes (Chen et al. 2008), graphene (Zhu et al. 2010), etc. The use of carbon nanotubes along with metallic nanoparticles have been found to enhance the electron transfer, while the catalysis is performed by the metallic centres. However, the presence of chloride in the electrolyte has been found to interfere with the catalytic ability of many metallic nanoparticles. Hence, the possibility of exploiting the independent electrocatalytic nature of carbon nanotubes for the measurement of glucose has been attempted in this study. Only few reports are available on the electrocatalytic nature of pristine CNTs towards sensing applications. These sensors were investigated in simulated samples and no real-time analysis was performed in the earlier studies (Ye et al. 2004). In the present study, a mildly alkaline electrolyte is employed instead of the highly alkaline systems reported earlier to ensure that there are no adverse effects on the biological sample being investigated. Macrophages were stimulated using lipopolysaccharides to monitor the glucose utilization by the cells. Glucose utilization was measured in macrophages both in unstimulated and stimulated conditions in an effort to understand differences between these two conditions that can be used for possible detection of inflammatory conditions.

Materials and methods

Materials

d-Glucose (Hi-media), nafion (M/s Sigma-Aldrich Ltd), and multi-walled carbon nanotubes (CNTs) (Nanomor, USA) were used in the study. Lipopolysaccharide (LPS) was procured from (M/s Sigma-Aldrich Ltd). Sodium hydroxide, potassium dihydrogen phosphate, dipotassium hydrogen phosphate, acetic acid, ascorbic acid, citric acid, and uric acid were purchased from Merck, India. Glassy carbon electrode (GCE), KCl saturated Ag/AgCl reference electrode, and platinum wire counter electrodes were purchased from CH Instruments, Inc., USA, and used for the electrochemical measurements. Deionized water was used to prepare all solutions.

Modification of working electrode

The glassy carbon electrode was cleaned as mentioned elsewhere (Thiagarajan et al. 2016). Carbon nanotubes (CNT) were dispersed in 0.05% of nafion solution and sonicated for 1 h. Then, 3 µL of this solution was drop-casted on the surface of the glassy carbon electrode and dried for 1 h. This electrode was denoted as CNT/GCE and was used as the working electrode for electrochemical measurements.

Characterization

The morphology of carbon nanotubes was observed using field-emission scanning electron microscopy (FE-SEM, JSM 6701F, JEOL, Japan). The sample was sputter-coated with a thin layer of gold and imaged at an accelerating voltage of 3 kV. The quality and purity of the carbon nanotubes were evaluated using Raman spectroscopy (LabRam HR800, Horiba Scientific, Japan). The spectrum was acquired between 0 and 2000 cm−1 in a moisture-free environment.

Electrochemical measurements

The electrochemical analyses were carried out using an electrochemical analyzer (CHI600C, CH Instruments, USA). A three-electrode system was employed for cyclic voltammetry and amperometry recordings. Platinum wire was used as the counter electrode, while Ag/AgCl electrode (saturated, 0.1 M KCl) was employed as the reference. The CNT/GCE served as the working electrode. Cyclic voltammograms were recorded in phosphate buffered saline medium (PBS, pH 7.4) at 298 K and a scan rate of 0.01 Vs−1. The amperometric measurements were performed at time intervals of 100 s following addition of specific concentration of glucose at an applied potential of − 0.25 V. Each step in the amperometric profile corresponds to the addition of 1 mM glucose.

Cell culture studies

Mouse macrophage cells (IC-21) were cultured in Dulbecco’s Modified Eagles Medium (DMEM) with fetal bovine serum (FBS, 10%) and penicillin/streptomycin (1%, Gibco, USA) and incubated in 5% CO2 at 37 °C. After cells attained confluency, they were trypsinized and centrifuged for 5 min at 4000 rpm. After discarding the supernatant, the cells were suspended in 1 mL of DMEM. The cells were seeded with different densities (1, 2, 5, 8, and 10 × 103 cells) in two sets. One set of cells was maintained in DMEM, while another set of cells was supplemented with LPS containing DMEM. After 24 h, the spent medium was collected and glucose measurements were made using the developed electrochemical sensor.

Results and discussion

Characterization

The surface morphology and Raman spectrum of the as-purchased CNTs are shown in Fig. 1.

Fig. 1
figure 1

a Scanning electron micrograph and b Raman spectrum of carbon nanotubes

Figure 1a reveals the presence of a dense network of uniform-sized nanotubes with an average diameter of 40–50 nm. The Raman spectrum of the CNTs shown in Fig. 1b displays a lower intensity D band at 1320 cm−1 and a higher intensity G band at 1573 cm−1. These values are in agreement with earlier reports for MWCNTs (Bokobza and Zhang 2012). The presence of the radial breathing mode (RBM) at 253 cm−1 provides additional support for the presence of MWCNTs.

Electrochemical measurements

Figure 2 shows the cyclic voltammograms recorded for the bare GCE and CNT-coated GCE working electrode in the presence of 1 mM glucose. An oxidation peak appears at − 0.25 V in the modified electrode in the presence of glucose. No peak is observed for bare GCE in the presence of glucose. The oxidation peak in the CNT-coated GCE arises due to the conversion of glucose to gluconic acid that is facilitated by the CNTs on the electrode surface.

Fig. 2
figure 2

Cyclic voltammogram of bare GCE and CNT-coated GCE in the presence of 1 mM glucose in PBS (pH 7.4)

Earlier reports have indicated that the glucose oxidation can occur in alkaline medium and the electron transfer can be mediated by the presence of carbon nanotubes and remains unaffected by chloride ions in the medium (Wang et al. 2007). While the earlier reports had employed sodium hydroxide containing chloride ions as the electrolyte, the present study has used mildly alkaline phosphate buffered saline (pH 7.4) that also contains chloride ions. The appearance of the glucose oxidation peak indicates that the mildly alkaline conditions provided by the phosphate buffered saline is sufficient for the oxidation of glucose to gluconic acid catalyzed by the CNT-modified surface that also captures the resultant electron transfer efficiently. Though the exact mechanism for the electrocatalytic behavior of MWCNTs has not yet been deciphered, it is believed that a combination of defect sites at the cap and the presence of oxygen-containing functional groups contribute to the electrocatalytic effect of MWCNTs (Hu and Hu 2009). The alkaline medium has been reported to activate the surface functionalities in MWCNTs (Ye et al. 2004). Moreover, the surface roughness also contributes in enhancing the sensitivity of the CNT-modified surface towards the analyte. According to the Incipient Hydrous Oxide Adatom Mediator model (IHOAM), the defective sites in the CNTs facilitate the adsorption of the hydroxyl ions that catalyze the oxidation of glucose to gluconic acid (Niu et al. 2016). However, the participation of the trace amounts of metal catalyst used for the preparation of CNTs in the catalytic transformation also cannot be ruled out. The nafion coating retards diffusion of larger molecules, thereby limiting interference. Figure 3 depicts the schematic representation of the reaction occurring at the working electrode.

Fig. 3
figure 3

Schematic representation of reaction mechanism occurring at the working electrode

Figure 4 shows the effect of scan rate on the oxidation peak in the presence of 1 mM of glucose. The peak current shows a progressive increase in the presence of glucose at increasing scan rates. The linear relation between scan rate and current indicates that the oxidation reaction is confined to the surface of the electrode.

Fig. 4
figure 4

a Cyclic voltammograms of CNT/GCE by varying the scan rate from 0.01 to 0.1 V/s and b plot of scan rate versus current

The concentration-dependent response of the developed biosensor was determined by increasing the concentrations of glucose. It was observed that the current progressively decreased with an increase in the concentration of glucose up to 5 mM (Fig. 5). The plot of concentration versus current exhibits a linear trend with a negative slope and linear regression of 0.98. This clearly indicates that the oxidation reaction is a surface controlled phenomenon at the CNT-coated GCE.

Fig. 5
figure 5

Plot of concentration of glucose versus current

Figure 6a shows the amperometric profile recorded for progressive addition of glucose to the medium at an applied voltage of − 0.32 V. A linear relationship is obtained for the concentration and current that can be used to quantify the amount of glucose present in the sample (Fig. 6b). The decrease in peak current may be attributed to adsorption of gluconic acid on CNT and electrode. The formation of hydrogen bond between carboxylic functiional group and defective site in CNT may leads to the adsorption of gluconic acid on CNT (Dantas et al. 2014). Response time is the time required to achieve stable state of sensor response toward the substrate from the moment of its addition to the electrolyte. The time taken for the sensor to achieve stable current after addition of the sample was found to be 3 s.

Fig. 6
figure 6

a Amperometric pattern of CNT/GCE for different concentrations of glucose and b plot of concentration of glucose versus current showing the linear range of the developed biosensor

The plot of current versus concentration of glucose (Fig. 6b) shows a linear regression of 0.986 and a linear range from 2 to 8 mM of glucose. The various sensing parameters for the enzymeless sensor were calculated and are summarized in Table 1.

Table 1 Various sensing parameters of the developed biosensor with their formula and values

It is evident from Table 1 that the sensor exhibits a limit of detection of 1.59 mM and a linear range of 2–8 mM. The normal concentration of blood glucose is 4–5.5 mM (Suneesh et al. 2013), which lies in the working range of this enzymeless sensor.

A comparison of the different enzymeless glucose sensors reported in literature is given in Table 2.

Table 2 Comparison of the developed glucose biosensor with previous reports

Effect of interferents

The designed biosensor was tested towards the potential interferents like ascorbic acid, uric acid, citric acid, etc. Figure 7 shows the amperometric response of biosensor towards 1 mM glucose and other interferents at − 0.32 V in PBS. The concentration of each interferent was 1 mM. From Fig. 7, it is evident that the sensor responds only to the addition of glucose indicating its specificity at the given potential.

Fig. 7
figure 7

Amperometric detection of glucose and other interferents in PBS at an applied potential of − 0.32 V

The detection of glucose in samples has wide-range applications in many fields that include health, food, beverages, and biotechnology. The use of enzyme-based sensors becomes expensive due to their non-reusable nature. The use of enzymeless sensor with a better stability and reusability without compromising the selectivity can overcome the limitations of enzyme-based sensors. The CNT-coated GCE reported in the present study exhibits high selectivity and rapid response. The sensor could be reused for 20 times with a decrease of only 11.9% in current recorded after 20 runs. The dry stability of the sensor was evaluated at room temperature and it was found that after 7 days, a 22.6% decrease in the peak current.

Measurement of glucose in macrophage-cultured cell culture medium

To evaluate the utility of the developed sensor for measuring glucose in biological samples, the sensor was employed to determine the glucose utilization of macrophages in the unstimulated as well as stimulated states. Spent medium collected from the culture plates was used for amperometric measurements. Amperometry was performed by applying a constant potential of − 0.32 V over a period of 100 s. The measured current is converted to glucose value using the standard plot constructed using known quantities of glucose. Measured glucose values were subtracted from supplemented glucose concentrations, so that glucose utilization was calculated. Glucose utilization in unstimulated and stimulated macrophages is depicted in Fig. 8.

Fig. 8
figure 8

Glucose utilization in stimulated and unstimulated macrophages with respect to the cell seeding densities

It is observed that macrophages in the unstimulated condition showed a slight but progressive increase in the glucose utilization values with increasing cell numbers. However, the increase was only 5% at a seeding density of 10,000 cells when compared to the glucose utilized by 1000 cells. This suggests that the cells are in the quiescent phase. In contrast, the cells stimulated with LPS showed a significantly higher glucose utilization at all seeding densities when compared with their unstimulated counterparts. A distinct increase in the glucose utilization was observed with increasing cell numbers in the LPS-stimulated macrophages. A 67% increase in glucose utilization was measured in the stimulated macrophages at a seeding density of 10,000 when compared with the values obtained for 1000 cells. A 1.6- to 2.6-fold increase in glucose utilization was observed in the LPS-stimulated macrophages when compared with the unstimulated cells. This difference in glucose utilization between the stimulated and unstimulated macrophages arises due to the active remodeling of the actin cytoskeletal network that occurs under stimulated conditions leading to a pronounced morphological transformation in the macrophage (Fig. 9). A recent report has demonstrated that LPS-stimulated macrophages exhibit down-regulation of ATP synthesis from fatty acid oxidation and hence is heavily dependent on the glycolytic pathway and not the oxidative phosphorylation to meet the energy demands associated with the cytoskeletal remodeling (Venter et al. 2014). Our data support this mechanism as we observe a distinct twofold increase in the glucose utilization by macrophages stimulated with LPS.

Fig. 9
figure 9

Inverted microscope images of unstimulated (a) and stimulated (b) macrophages (× 40 magnification)

Concluding remarks

Carbon nanotubes have been widely explored as an interface material along with an enzyme for electrochemical detection of various analytes including glucose. The present work demonstrates the intrinsic catalytic ability of MWCNTs. Along with their excellent electron transfer capability, the MWCNTs formed a catalytic interface for efficient electrochemical enzymeless detection of glucose within 3 s. The biosensor exhibited a linear range from 2 to 8 mM with a limit of detection 1.59 mM that is superior to many enzymeless glucose sensors reported in literature. The developed biosensor is unaffected by the potential interferents. These attributes enable real-time detection of glucose with the developed biosensor that may find applications in clinical diagnostics. The sensor was found to effectively detect glucose utilization in stimulated and unstimulated macrophages that can be explored in future for clinical diagnosis of inflammatory disorders.