Introduction

In recent years, the cost of energy has increased faster than other agricultural costs. While agricultural pumping stations, their energy consumption and efficiencies have been improved (Abadia et al. 2008), there are still opportunities for further improvements. Water pumping stations usually use fixed speed pumps that have a good efficiency over a small range of pressure and flows. If different flows and pressures are required, unsuitable pump speeds will yield excessive energy losses. This imposes additional costs, especially on pressurized irrigation systems, which are constantly changing their irrigation needs, sometimes monthly.

Today, more than 60% of electricity consumption in the industry is from electric motors. Therefore, increasing their efficiency leads to significant savings in energy consumption (Li et al. 2019) and a reduction in pollution and emission of greenhouse gases that cause climate change (Li et al 2020; Cheng et al. 2020; Cheng et al. 2019). Constant speed pumps have a fixed rotational speed of the impellers which limit the ability to modify the flow. Consequently, use of a constant speed of impeller reduces the flexibility of the pumping system. In contrast, there are variable speed pumps (VSP) that have the ability to adjust the impeller rotation and can be used to make desired changes in the pumping system.

In the information provided by the pump manufacturers, discharge-head curves are usually provided for several impeller diameters and for two or more limited impeller speeds. With VSP, the pump is theoretically capable of operating on an unlimited number of pump curves that range between a minimum and a maximum. When the discharge demand differs from the design, the required demand (discharge and head) can be met by making a change in the pump without making any special changes in the system and without imposing additional costs (Lamaddalene and Khila 2012). In this regard, the following considerations may be important:

  1. (i)

    As the head loss increases in the pressurized pipe system, the required head increases.

  2. (ii)

    Over time and with the development of the irrigation and drainage project area, the need for discharge and head will increase.

  3. (iii)

    In the months when the water requirement of the irrigation plan is less than the maximum, the need for discharge and head is reduced. With proper use of VSP in the pumping station, the required discharge and head can be adjusted every month, or with other frequencies.

Due to the dependence of pressurized irrigation systems on the pumping stations, various methods for improving energy consumption have been studied. Fernandez-Pacheco et al. (2015) investigated variable speed drives used in centrifugal pumps. They found that conventional discharge control methods use a control valve that reduces the efficiency of the pump and increases the operating head of the pump. By examining the characteristic curves of the pump and the system, they showed that the use of speed adjustment drives to reduce the flow rate increases the efficiency and reduces the losses significantly.

Hanson et al. (1996) divided an irrigation area into five sections and considered different irrigation conditions in each section. They used a variable frequency drive to change the rotational speed in the pump and to provide the required discharge in individual sections. They found that the energy consumption of the studied sections when using a variable frequency drive led to an energy reduction of 32–56%.

Lamaddalene and Sagardoy (2000) studied pressurized irrigation systems. They proposed a way to increase pump efficiency, which would reduce the conflict between farmers and the problems caused by improper use of irrigation water. Due to the change in the curve of variable speed pumps at different speeds, Lamaddalene and Sagardoy (2000) were able to calculate energy consumption according to changes in system needs. They found that power consumption was reduced by 5–21% if a variable speed pump was used.

Moreno (2008) proposed a new method for determining the characteristic curve of pumps and the efficiency of the pumping stations that can be used to calculate the necessary parameters for the selection of the pump. Using this method, pump selection can occur more accurately and energy can be saved.

Diaz et al. (2009) investigated energy storage in irrigation networks that are adjusted based on the required head. They selected an area in southern Spain and surveyed that area under four management scenarios with different levels of water demand. The results showed that the use of methods such as VSP and zoning significantly reduced the water demand of pumping stations by more than 27%. Lamaddalene and Khila (2012) investigated energy savings by using a variable speed pump in two irrigation areas in southern Italy. They used COPAM software to determine the pipe system characteristic curve and showed that the energy consumption is reduced by 27–35%.

These results are consistent with the results of studies such as Lamaddalene and Sagardoy (2000); and Diaz et al. (2011). However, depending on the conditions of each design, whether agricultural or industrial, the amount of savings in water and energy consumption and increase in efficiency will be different.

Khayatzadeh and Ghafouri (2015) developed a centrifugal pump system that incorporated multiple stages, each coupled to an induction motor. Two different flow control strategies were used that involved both constant and variable speed pumping methods. The authors found a very large (83%) energy savings when the variable pumping system was employed.

Khadra et al. (2016) used a multi-step approach to incorporate pressure and pumping requirements for pumping stations with fixed and variable head control. They focused on an on-demand irrigation system in Italy and found that under an optimal scenarios, a 49% improvement in performance could be achieved.

Application of a variable frequency drive (VFD)

Variable frequency drive (VFD) refers to a type of motor controller that can rotate the electric motor by changing the frequency and voltage in the electric motor. Other names used for electric drives include: variable speed driver, adjustable speed drive, adjustable frequency drive, AC drive, micro drive and inverter.

Frequency (or Hz) is directly related to motor speed (rpm). In other words, the higher the frequency, the faster the motor speed. If the user does not need an electric motor that rotates at full speed, an electric drive can be used to lower the frequency and voltage to meet the requirements of the electric motor. As the required motor speed in the intended application changes, the electric drive can easily meet modified requirements by raising and lowering the motor speed. A VFD circuit consists of three parts: (i) the rectifier section, (ii) the filter section and (iii) the switching or inverter section.

Most variable frequency drives first convert the input power to direct current (DC) and then return it to alternating current (AC) at the desired frequency. The particular method the drive uses to convert direct current to alternating current depends largely on the size and power of the motor. With less expensive systems, the output voltage is usually square, which is not a problem for AC motors, but sometimes an extra unit is used to bring the waveform closer to a sine waveform (Zell 1989).

The converter consists of six diodes, which are similar to the one-way valves used in piping systems. These diodes provide current in only one direction. For example, if the voltage of phase A is more positive than the voltages of phase B or C, then the desired diode opens and current flows. If phase B is more positive than phase A, then the phase B diode opens and the phase A diode closes. The same situation occurs for the 3 diodes on the negative side. Therefore, six pulses of current are generated when each diode is opened and closed. This is called a six-pulse electric drive, which is the standard configuration for variable frequency drive drives.

However, despite the VFD advantages, there are a few disadvantages also associated with the VFD system. The primary drawback of the VFD system is the initial setup investment. For a factory or a plant where multiple high horsepower motors need to be controlled using VFDs, requires high investments. In addition, VFD causes motor heating and needs special motors construction. The construction needs special types of Motor insulations, as well as the motors need to be specified for inverter rated applications (Ruminski 2016). More details about VFD are beyond of this paper and more information can be found in Lee et al. (2020) and Ramesh et al. (2020).

The present study is carried out to evaluate the efficiency of variable speed pumps in water distribution systems. Two types of pumping stations (constant speed and variable speed) are considered. The area of agricultural lands is 70 hectares with wheat, corn and alfalfa crops around the city of Tabriz, Iran. The purpose of the study is to reduce the electricity consumption.

Material and methods

Site location and sprinkler irrigation characteristics

One of the design goals of each pumping station is that the pump operates close to its optimal efficiency. However, during operation, the pumping system may experience many fluctuations. As a result, setting a constant speed for a pump that operates near its optimum condition is difficult. This enhances the need to change the design of pumping stations.

The agricultural study is located in Tazeh Kand village, 30 km southwest of Tabriz. The water pumping station includes a fixed speed centrifugal electric motor pump for use in a sprinkler irrigation system. The selection of this pump is based on the maximum consumption of the sprinkler irrigation network in July. Figure 1 shows the location of the farm under study.

Fig. 1
figure 1

Location of the test site in the Tazeh Kand village near Tabriz, Iran

Figure 2 provides average monthly irrigation water demand during cultivation time from May–October. The maximum irrigation network consumption in July is 1541.05 m3/ha. October has the minimum irrigation demand of 692.81 m3/ha.

Fig. 2
figure 2

Average monthly irrigation water demand

As shown in Fig. 3, in the sprinkler irrigation system, three lateral pipes are connected to the main pipe. The required discharge for these three lateral pipes is 0.020 m3/s. The required head at the inlet of each lateral pipe is 35.14 m. The pipes are made of polyvinyl chloride (PVC) and the system capacity is 0.06 m3/s. The suction head is 2.5 m and the friction loss due to the joints, bends and filter in the suction pipe is equal to 1.0 m.

Fig. 3
figure 3

Sprinkler irrigation system consists of three lateral pipes branching from the main pipe

Head loss calculations

The useful power of the pump (P) is the amount of energy that is transferred to the fluid per unit time by the pump and is calculated as follows:

$$ P = \gamma QH_{T} $$
(1)

In Eq. (1), the specific gravity of the fluid (\(\gamma\)) is in terms of N/m3, the discharge (Q) is in m3/s, and the total dynamic head (HT) of the pump has units of m. With these units, the useful power will be in terms of watts (W). The HT is defined as sum of the geometric head and the friction head. Geometric head is the difference between water levels in suction and delivery reservoirs. Friction head includes sum of the friction head and minor head losses due to bends, valves, transitions, etc.

Pump efficiency (η) is the ratio of the useful power of the pump to the power required to operate the pump (known as brake power, BP).

$$ \eta = \frac{P}{BP} $$
(2)

The efficiency of centrifugal pumps is usually between 60 and 90%.

The application of the law of similarity for pumps adapts the pump to the water supply system. This means that the discharge or head can be changed by changing the rotation speed of the pump impeller; the pump flow is directly related to the impeller rotation speed. Using this concept, the following expression can be written.

$$ \frac{{Q_{1} }}{{Q_{2} }} = \frac{{rpm_{1} }}{{rpm_{2} }} $$
(3)

where Q is the pump discharge and rpm is the rotation speed of the pump impeller.

On the other hand, the head or the total dynamic head produced by the pump is proportional to the square of the discharge according to the Darcy–Weisbach relation. Therefore, we have:

$$ \frac{{H_{1} }}{{H_{2} }} = \left( {\frac{{rpm_{1} }}{{rpm_{2} }}} \right)^{2} $$
(4)

Brake power is proportional to the third power of the discharge according to Eq. (5).

$$ \frac{{BP_{1} }}{{BP_{2} }} = \left( {\frac{{rpm_{1} }}{{rpm_{2} }}} \right)^{3} = \left( {\frac{{Q_{1} }}{{Q_{2} }}} \right)^{3} $$
(5)

The total dynamic head for a system is calculated using the following procedure that will now be described in detail.

In Fig. 2, the lateral pipe is critical at station 4 (because it is both at a greater distance and at a higher altitude than the rest of the locations). The required head or pressure at the beginning of the lateral pipe is equal to 35.14 m. Using the slope of the natural ground (S) and the length of the pipe (L), the elevation difference between the stations 1 and 4 is:

$$ H = \mathop \sum \limits_{i = 1}^{3} L_{i} S_{i} = 300 \times 0.015 + 2 \times 150 \times 0.01 = 7.5 m $$
(6)

The calculation of the friction loss (hf) in the main pipe between stations 1 to 4 using the Hazen–Williams relation is presented in Table 1 where C is the coefficient of friction in the Hazen–Williams relation and is assumed to equal 150 for PVC pipe. In addition, V denotes to the mean flow velocity in pipe (Table 1).

Table 1 Friction loss (hf) in the main pipe between stations 1 and 4

Head loss occurs because intermediate structures such as valves, bends and pipe transitions result in a pressure decrease in the flow. These loss terms are often distinguished from frictional losses and are sometimes termed “minor losses.” The minor loss term (hf) is calculated according to Fig. 2 and Table 2; in the table, K refers to the loss coefficient in valves and fittings. The last column in Table 2 is obtained from the following equation.

$$ h_{f} = K \times \frac{{V^{2} }}{2g} $$
(7)
Table 2 Head loss in valves, fixtures and bends between stations 1 and 4

The summation of all the above-noted head loss terms is 1.22 m. With this value now determined, it is possible to calculate the total head required to generate the necessary flow. That calculation is shown in Table 3.

Table 3 Total dynamic head required by the sprinkler irrigation system

The maximum network consumption in July is 0.06 m3/s and the total dynamic head is 58.11 m. To determine the system curve for the variable discharge, the total dynamic head value must be calculated according to the above method (Tables 1, 2 and 3) for a number of discharge flows. Typically, a few discharge flows are selected above and below the designed value (0.06 m3/s) in this case. The resulting system curve from these calculations is provided in Fig. 4.

Fig. 4
figure 4

System curve for sprinkler irrigation network

It should be noted that the intersection of the system curve (Fig. 4) with the y-axis is 45.14 m, which is the sum of the required head at the beginning of the lateral pipe, the sum of the suction head and the height difference between stations 1 and 4.

Based on these calculations, a suitable centrifugal pump type EA-125–50/2 has been selected. At a 50 Hz frequency, the engine speed is 1450 rpm. The diameter of the pump impeller is 0.319 m.

In Fig. 5a, the characteristic curves of the pump and the characteristic curve of the pipe system are plotted together and their intersection defines the operating point. Based on Fig. 5a, the operating point of the pump is found to correspond to Q = 0.052 m3/s and H = 55.60 m.

Fig. 5
figure 5

Pump and system characteristic curves

According to the pump manufacturer, the pump efficiency versus discharge is shown in Fig. 5b. At a design flow rate of 0.06 m3/s, the pump efficiency is 74.81%.

Table 4 presents the calculation of efficiency, brake power and electricity consumption of the sprinkler irrigation system under the current design conditions (constant speed pump). In the current design conditions, the pump efficiency varies between 69.6 and 74.5%. The total electricity consumption is 3523.77 kWh during the irrigation seasons.

Table 4 Calculation of efficiency, brake power and electrical consumption of sprinkler irrigation system in the current design conditions (constant speed pump)

Sprinkler irrigation system in this study is a case study from a small agricultural area; the lowest pressure in the system is not below the vapor pressure of water. Consequently, no arrangements have been made in the system for the cavitation and water hammer phenomenon. Water hammer presents negative effects to pipe lines that can be prevented by some facilities like a pressure vessel/surge tank, bypass systems, etc. Surge tanks can control both negative and positive waves that can destroy pipe lines. Detail of design and implementation of surge tanks can be found in standard fluid-mechanics books.

Results and discussion

Using Eqs. (35) and Fig. 6, the characteristic curves of the pump at different pump motor speeds are shown. The operating points are obtained from the intersections of these curves with the system curve. Calculations of pump speed change with required discharge changes in different months, as listed in Table 5. The table presents calculations of efficiency, brake power and electricity consumption of the sprinkler irrigation system using a pump with variable speed. The efficiency of the pump with variable speed ranges from 70.3 to 97.6%. These are improvements compared to the constant speed pump. Total electricity consumption is equal to 2235.21 kWh during irrigation seasons, which is a reduction of 1288.6 kWh compared to the electricity consumption of the constant speed pump.

Fig. 6
figure 6

Operating points of the system at different pump speeds

Table 5 Calculations of efficiency, brake power and electricity consumption of the sprinkler irrigation system using a variable speed pump (VSP)

Using Eq. (4), the changes in pump speed for different months are plotted for both fixed speed and variable speed pumps. The pump speed varies from 1450 rpm during maximum water consumption (July) to 651.88 rpm in October. By reducing the pump impeller rotational speed, energy is conserved (Fig. 7).

Fig. 7
figure 7

Variation of pump impeller rotation in different months for fixed speed pump and variable speed pumps

Using Eq. (5), the changes in pump efficiency in different months are plotted for both fixed and variuable speeds (Fig. 8). The results show that a variable speed pump increases the average pump efficiency by 18.7%. Improving the pump efficiency is greater with increase in discharge.

Fig. 8
figure 8

Variation of pump efficiency in different months for two modes of fixed speed pump and variable speed pump

Figure 9 shows the changes in the power consumption of the pump in different months for the two pump modes. Power consumption in different months for the constant speed pump mode varies between 440.2 and 801.96 kWh. On the other hand, for the variable speed pump mode varies between 294.65 and 558.19 kWh. The results show that the variable speed pump system reduces energy consumption about 57.6% compared to the fixed speed pump. Therefore, using a variable speed pump saves electricity consumption.

Fig. 9
figure 9

Pump power consumption in different months for two modes of pump operation

In Fig. 10, the energy line of the system in schematic form is provided. Linear decreases in head are caused by frictional losses, while step change sin head corresponds to minor loss terms.

Fig. 10
figure 10

Energy line of the system in schematic form

Conclusions

From this study, it is apparent that using a variable speed pump in a pressurized irrigation system increases the flexibility of the irrigation system, improves pump efficiency and reduces electrical energy consumption and cost. As the efficiency of the pump increases, the depreciation of the pump decreases and the useful life of the pump increases, thus reducing the need for maintenance.

The primary drawback of the VFD system is the initial setup investment. For a factory or a plant where multiple high horsepower motors need to be controlled using VFDs, requires high investments. In addition, VFD causes motor heating and needs special motors construction. The construction needs special types of Motor insulations, as well as the motors need to be specified for inverter rated applications.

In this study, the efficiency of stations equipped with variable speed pumps under all operating conditions exceeds that of stations equipped with fixed speed pumps. The results showed that the use of variable speed pumps not only increases efficiency but also aids in meeting water needs. The results showed that using a variable speed pump increases the average pump efficiency by 18.7%.

The power consumption for a variable speed pumping station during irrigation seasons is much less than that for constant speed pump (ΔP = 1288.6 kWh). This is 57.65% less than with a constant speed pump. As a result, the use of variable speed pumps in pressurized systems is recommended.

Although this study refers to the pilot area for the sprinkler irrigation system, the presented methodology can be applied to other water distribution networks. The calculation of pump impeller speed, power and the operation hours of pump will be same in other projects.