Skip to main content
Log in

Reduction of background in CR-39 SSNTD using chemical pre-etching methods

  • Published:
Indian Journal of Physics Aims and scope Submit manuscript

Abstract

Presently, CR-39 Solid State Nuclear Track Detectors (SSNTD) is being used for Fast Neutron Personnel Monitoring in India. Individual detectors are cut manually from CR-39 sheets. Laser-cutting of the sheets will ensure precision and also save on the laborious efforts involved in sheet cutting. It was observed that there is a slight increase in background tracks due to laser-cutting. Studies were carried out on the effect of chemical pre-etching at higher temperatures in properties of CR-39 such as the background, sensitivity and minimum measurable dose. For this purpose a pre-etch step was included in the normal processing of the CR-39 foils in an elevated temperature electrochemical cell (ETECE cell) and the duration for pre-etch step at elevated temperature was optimized.

Samples of CR-39 exposed to dose equivalents ranging from 1 mSv to 10 mSv using Am-Be neutron source were processed by both the methods, under normal processing using ECE cell and in the optimized chemical pre-etch followed by normal processing. The dose responses of CR-39 processed by both methods are compared in this paper.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R J Tanner, D T Bartlett and L G Hager Radiation Measurements 40 549 (2005)

    Article  Google Scholar 

  2. J R Harvey and A R Weeks Radiation Protection Dosimetry 20 89 (1987)

    Google Scholar 

  3. M P Dhairyawan, P K Marathe and O P Massand Radiation Measurements 36 435 (2003)

    Article  Google Scholar 

  4. Dale E Hankins, Steven G Homann and Brooke Buddemeier Personnel Neutron Dosimetry Using Electrochemically Etched CR-39 foils Publication by Lawrence Livermore National Laboratory (1989)

  5. Y V Rao, S Kar, G Valli, D G Joshi, V K Chaddaa, R K Nigam, OP Massand, M P Dhairyawan and P K Marathe Image Analysis System for Automation in Fast Neutron Personnel Monitoring using CR-39 Solid State Track Detector, International Conference on Automation ICAUTO-95 (Indore, India) (1995)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rupali Rohatgi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rohatgi, R., Sathian, D., Jayalakshmi, V. et al. Reduction of background in CR-39 SSNTD using chemical pre-etching methods. Indian J Phys 83, 845–850 (2009). https://doi.org/10.1007/s12648-009-0038-7

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12648-009-0038-7

Keywords

PACS Nos.

Navigation