The transversus abdominis plane (TAP) block is increasingly used to provide postoperative analgesia for open and laparoscopic abdominal surgeries. Ultrasound guidance to identify the different intermuscular planes of the abdominal wall can increase the success rate of the procedure. When anesthesiologists carry out this procedure, the most critical step is identifying the muscle layers of anterolateral abdominal wall. The desired target region of needle insertion and local anesthetic for TAP block is the plane between the transversal abdominis and internal oblique muscles. Nevertheless, this procedure may be hampered by imaging artifacts that inaccurately reproduce the anatomical structures.
A subcostal TAP block was performed in a 60-year-old female for postoperative analgesia using a 13–6 MHz linear probe (Edge; Sonosite, Bothell, WA, USA) after laparoscopic radical hysterectomy in the postanesthesia care unit. The subcutaneous area (SC), external oblique (EO), internal oblique (IO), and transversus abdominis (TA) muscles were seen as mirror images (TA′, IO′, EO′, and SC′) below the transversalis fascia (Figure, panel A). Mirror-image artifacts partly disappeared (SC′ and partial EO′) when compressing the probe and the intra-abdominal contents were detectable (Figure, panel B).
The mirror-image artifact is a reverberation artifact that arises when the ultrasound beam reflects off of a highly reflective interface, such as the diaphragm and pleura, and causes bending of the beam before returning to the transducer, which violates the key assumption that an echo returns to the transducer in a straight line after a single reflection. The interface between the transversalis fascia and artificial pneumoperitoneum acts as an acoustic mirror and duplicates abdominal muscles below the peritoneum in the patient. Anesthesiologists may change the scanning plane or the angle of the probe to expose this artifact in ambiguous cases. If not properly recognized, mirror-image artifacts can be mistaken for normal anatomic structures and can lead to harmful interventions.
Disclosures
Neither author has any conflict of interest.
Funding statement
This work was unfunded.
Editorial responsibility
This submission was handled by Dr. Vishal Uppal, Associate Editor, Canadian Journal of Anesthesia/Journal canadien d’anesthésie.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Ye, H., Wei, P. & Yang, Jj. Ultrasound mirror-image artifacts during transversus abdominis plane blockade. Can J Anesth/J Can Anesth 70, 443–444 (2023). https://doi.org/10.1007/s12630-022-02384-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12630-022-02384-0