To the Editor,

We would like to thank Dr. Parida for his comments on our study of the anatomy of the right upper lobe as it relates to the positioning of right-sided double lumen endotracheal tubes.1,2,3,4 Older studies describing variation in bronchial anatomy with respiratory cycle were cited to highlight concerns with measurement of the tracheobronchial tree.5,6 Anatomical measurements of the airway have been obtained in different manners: cine-radiographic bronchography,6 cadavers,4 resin casts,4 and flexible bronchoscopy.4 Computerized tomography (CT) with three-dimensional (3-D) reconstruction2 has refined measurements in spontaneously breathing patients. Except for the cine-radiographic bronchography and the flexible bronchoscopy, all these measurements are performed in one static period of the respiration cycle.

While the addition of dynamic alterations in airway length during the respiratory cycle could be considered, we were obliged to reproduce the methods of Kim et al. to ensure comparability of results. With regard to standard timing of measurement with the respiratory cycle, our protocol specifies that the patients took a deep inspiration and held it for the duration of the CT-scan image acquisition. This protocol is widely used among conscious, spontaneously breathing patients. We appreciate Dr. Parida’s concern regarding the training of observers. The two observers in our study regularly use CT-scan reconstruction and the inter-observer agreement documented was substantial with both methods (Kim’s method: intraclass correlation coefficient [ICC] = 0.84; carina-to-carina method: ICC = 0.95), and both measures were closely related (ICC = 0.93; P < 0.001). Our clinical practice has shown that after a brief training, thoracic anesthesiologists can make these measurements on standard, coronal CT-scans, without 3-D reconstruction. Our experience suggests that clinician measurements approximate the precise measurement within 2 mm. Finally, we mentioned in our article that these measurements apply only to the Broncho-Cath (Mallinckrodt Medical Ltd, Athlone, Ireland) right-sided double lumen tube (R-DLT) as the initial measurements by Kim et al. were done with this model of R-DLT.2 The figure shows the different models of R-DLT and it is easy to understand the specificity of Kim’s results and consequently of our conclusions.

We sincerely thank Dr. Parida for his comments. We hope our reply will addresses his concerns and allows readers to better apply our findings.

Figure
figure 1

Cuffs of right-sided double-lumen endobronchial tubes from top to bottom: Mallinckrodt, Portex, Sheridan, and Rusch. Images on left represent tubes as they would be placed in the airway. Images on right provide detail of each tube’s bronchial cuff.