To the Editor,

Use of hydroxyethyl starch (HES) has come under scrutiny as accumulating evidence has suggested that HES fluids are associated with an increased risk of acute kidney injury and death among the critically ill.1 These findings prompted Canadian2 and international regulators to issue warnings from 13 June 2013 to 18 July 2013 regarding the use of HES products. Regulatory warnings were widely discussed amongst our department membership at the time. We wished to determine the effect of these warnings on HES use in the operating rooms (OR) of The Ottawa Hospital (TOH), a tertiary care academic health sciences centre in Ontario, Canada.

Following approval of the Ottawa Health Sciences Network Research Ethics Board (#20140637, submitted September 2014), we performed an observational historical cohort study of patients undergoing both elective and emergency surgeries at TOH. We planned to use our anesthesia information management system to link HES exposure to postoperative outcomes. Variable fluid documentation practices in our electronic medical record precluded accurate quantification of HES exposure in individual patient data. As HES products were stocked on anesthesia drug carts and in our OR pharmacy, we were also unable to use individual patient prescription records to define exposure. We instead turned our attention to system-wide use of HES as determined by the quantity of such products ordered. Order records of HES arriving to the OR were obtained from the Logistical Services and Purchasing Department of our hospital. Given that any HES-containing product available to the OR was exclusively managed through the Logistical Services and Purchasing Department, we assumed that HES products dispensed to the OR were a reasonable surrogate for the volume of HES products administered to patients in the OR. We studied monthly ordering practices for the six-month period before the regulatory warnings (1 January to 30 June 2013) and then for 42 months after the warnings (until December 2016).

The Figure shows monthly totals of HES-containing fluids ordered to the OR from January 2013 to December 2016. From 1 January to 30 June 2013, the average number of HES-containing fluids ordered to the OR was 380 units per month. In the six months following the HES warnings in June/July 2013, an average of 74 units of HES per month were ordered to the OR marking an 81% drop in HES product ordering. Based on published cost of HES solutions in Canada,3 this change in HES ordering practice saved our institution over CDN $200,000 per year.

Figure
figure 1

Monthly number of hydroxyethyl starch (HES) units ordered to the operating room (OR) from 2013-2016. Negative (red) bars denote return of HES to the purchasing division of the hospital. No bar equals zero HES units ordered to the OR for that month. *Regulatory HES warnings June-July 2013; #anesthesia cart redesign with HES removed

We noted persistent HES use that exceeded 40 units per month throughout 2014, the year after regulatory warnings. In conjunction with a separate quality improvement initiative to standardize anesthesia drug cart contents, HES products were removed from the anesthesia drug carts and placed in the OR pharmacy. Following this change (Figure) to remove HES from the anesthesia OR drug carts, monthly HES ordering dropped to and was sustained at < 1% of pre-warning levels.

Research evaluating a variety of interventions indicates that it may take up to 17 years for evidence to change practice.4 Half of this time is spent in the implementation of established evidence. Our experience suggests that equipment re-design to force function behavior (e.g., removal of HES from anesthesia cart) may be required to bring about system change once messaging and education have been tried.5