Abstract
In Colombia, medical physics started formally about 3 decades ago. Two master’s programs in medical physics initiated activities at two different universities. In particular, the master’s program at the Pontificia Universidad Javeriana has been underway since 2012, and taking into account its projections, a team was established in 2015 in collaboration with the Universidad Distrital Francisco José de Caldas to conduct basic research on cancer treatment using neutron capture therapy (NCT). The primary goal of our initiative is to create the infrastructure required to adapt new technologies in our universities in the future. The long-term objective is to use neutron radiation to study not only NCT but also biomolecules, membranes, and materials. This will require the commissioning of an actual nuclear facility. Our group has been exclusively focused on carrying out calculations with GEANT4 because of its characteristics as open-source software, its accessibility, and its ample worldwide use and validation in the particle physics, nuclear physics, and medical physics communities. In this work, we present some results of our preliminary design for the ion accelerator column of a compact neutron generator. Also, we present the characterization of the kinematical and dose distributions of boron neutron capture processes using Geant4.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Since 1932, when the cyclotron was used to produce artificially created radioactive isotopes for medical applications in cancer treatment (Lawrence and Livingston (1932)), particle accelerators have transformed from high-tech experimental facilities, exclusive to laboratories for nuclear physics and elementary particles, mainly, to research and development tools in other areas of science and technology. Today, particle accelerators are in common use in biophysics laboratories, materials science, radiochemistry, semiconductors and microcircuits, radiotherapy, security, and a huge number of industrial applications. The development and dissemination of accelerators have been possible thanks to advances in the physics of charged particle beams, microwave technologies, the use of new materials, and control and processing methods, among others (Sauerwein et al. (2012)).
With the discovery of the neutron (Chadwick (1932)), research in nuclear physics and its applications was developed. Considerable efforts were focused on the so-called neutron capture. This type of nuclear reaction was described as early as 1935 (Taylor and Goldhaber (1935)). In 1936, the biological effects of the nuclear neutron capture reaction were specified, and its potential for use as a cancer therapy was suggested (Locher (1936)). This procedure was later called neutron capture therapy (NCT).
NCT combines the introduction of small amounts of a neutron absorber such as \(^{10}\text {B}, \,^{157}\text {Gd}\), and \(\,^7\text {Li}\) that are stored at the cellular level, subsequently being bombarded with low-energy neutrons, which trigger a reaction that releases ionizing radiation in the regions of greatest interest, thus providing a selective way to cause damage to tumor cells while at the same time minimizing the lethal effects on surrounding healthy tissue (Sauerwein et al. (2012)).
In particular, when NCT uses boron \((^{10}\text {B})\) as an absorbing medium, it is called boron neutron capture therapy (BNCT). The nuclear reaction that takes place is given by the following:
The main decay channel releases gamma rays \(\gamma \,(0.478\) \(\text {MeV})\), the so-called \(\alpha \) particles, i.e., \(^4\text {He} \,(1.47 \,\text {MeV})\) and lithium ions \(^7\text {Li} \,(0.84 \,\text {MeV}) \) within the cell tissue. This channel has a branching ratio of \(93.9 \%\). The secondary channel has a branching ratio of \(6.1 \%\) and releases only \(\alpha \) particles [\(^4\text {He} \,(1.78 \,\text {MeV})\)] and lithium ions \(^7\text {Li} \,(1.01 \,\text {MeV})\) without the production of gamma rays. These nuclear reactions yield high linear energy transfer (LET) \(^4\text {He}\) and \(^7\text {Li}\) with typical average values of 100–200 keV/\(\mu \)m and 20–40 keV/\(\mu \)m, respectively. Compared to the average cell diameter in the human body (\(\approx 50 \,\mu \)m), these reaction products are released within average path lengths of roughly 5–9 \(\mu \)m. Consequently, the destructive effects are confined to the boron-containing cell, while adjacent, healthy cells are, in theory, unaffected.
The efficiency of BNCT is, however, limited by the fraction of the deposited energy that cannot be controlled or targeted specifically. The impact of the therapy is then not exclusive to the targeted tumor cells, but can extend to the adjacent healthy cells as well. As a consequence, such an occurrence could potentially lead to unfavorable and harmful impacts on the surrounding healthy tissue. Therefore, to achieve a high efficiency in BNCT, a boron concentration of the order of \(10^9\) atoms per cell is required, then the boron concentration should be of approximately 35 \(\mu g\) per gram (35 ppm) of tumor tissue, while for healthy tissue, the concentration should not exceed 5 \(\mu g\) per gram (5 ppm) of tissue (Hanaoka et al. (2014); Hosmane et al. (2012)). High concentration can be achieved by either using a boron-containing compound that selectively accumulates in the cancer cells or by directly injecting a boron compound into the tumor. The accurate measurement of \(^{10}\)B concentration in both tumor and normal cells plays a crucial role for determining the maximum irradiation time during BNCT. Insufficient irradiation time may result in inadequate \(^{10}\)B concentration within the tumor cells, leading to ineffective destruction of cancerous cells. Conversely, with a prolonged irradiation time, the dose delivered to healthy cells could surpass the critical threshold, resulting in adverse effects. By achieving this balance between tumor damage and healthy tissue preservation, BNCT has the potential to treat specific types of cancer.
The BNCT development was primarily addressed to brain cancer, i.e., glioblastoma multiforme (GBM). This type of tumor is considered one of the most aggressive cancers and can rarely be surgically removed (Kankaanranta et al. (2012)). It is characterized by its aggressive proliferation and extensive invasion of healthy tissue before any symptoms appear. The rate of sterilization or destruction of these tumors is higher compared to other techniques, such as radiotherapy by X-rays.
The success of BNCT as a treatment for this class of tumors depends on several factors: an adequate concentration of \(^{10}\text {B}\) in the tumor cells, differential uptake of boron in tumor cells and in healthy cells, and sufficient fluence of thermal neutrons in the tumor region (Moghaddasi and Bezak (2017)).
For these reasons, current research focuses on the development of medications capable of transporting boron to cancerous tissues in a differential way, as well as neutron sources that pose no threat to a medical facility. Implementation of compact neutron generators is currently of considerable interest.
Finally, we have established collaborations with research groups around the world. That is the case for the group of Dr. K. Leung at the Lawrence Berkeley National Lab (LBNL) at the University of California, Berkeley, in the USA, for the design and construction of a compact neutron accelerator (Verbeke (2000); Verbeke et al. (2000)).
Compact neutron generator
Until 2009, most of the research for therapeutic treatments with BNCT was carried out using nuclear reactors that generate significant fluxes of neutrons through chain reactions of nuclear fission (the thermal reactors used for BNCT are typically research or test reactors, i.e., TRIGA model). The results of these studies are quite promising; however, the difficulties involved in having a nuclear reactor near a hospital facility prevent further research into neutron therapy (Kim and Kim (2009)). The generation of suitable neutron beams for BNCT near a hospital facility is a technological challenge. These slow neutron beams must be obtained in a safe and stable manner. Currently, the main advances have been made in the USA, Japan, China, Russia, the UK, Italy, Israel, and Argentina (Kim and Kim (2009); Kreiner et al. (2016)). After almost 60 years of research and development on BNCT with nuclear reactors, engineering efforts were focused on the development of a compact, hospital-based proton accelerator system for BNCT. Currently, a functional prototype of compact high intensity neutron generators is technologically available (Bavarnegin et al. (2019)).
Essentially, these compact neutron generators accelerate charged particles, i.e., D\(^+\) ions, which then collide with a deuterium (\(^2\)H) or tritium (\(^3\)H) rich target (titanium embedded with deuterium or tritium), generating the neutrons through a mechanism of nuclear fusion between the doped target ions (Leung et al. (2004)). With a \(^2\)H target, neutrons (n) are emitted with a kinetic energy of 2.45 MeV according to the reaction:
where the \(^3\)He is produced with a kinetic energy of 0.82 MeV. With a \(^3\)H target, the neutrons are emitted with a kinetic energy of 14.05 MeV according to the following:
and the \(^4\)He is produced with a kinetic energy of 3.54 MeV.
The compact neutron generator is mainly composed of the following modules: the ion source, extraction region, region of acceleration or accelerator column, a target, and the beam-shaping assembly (BSA), as shown in Fig. 1.
The prototype for the compact neutron generator that we are working on is based on what has already developed at LBNL (University of California, Berkeley) in the group of Dr. Leung (Verbeke (2000); Verbeke et al. (2000)). The specifications of this design are shown in Table 1.
As for the ion source, which ionizes deuterium at low pressure (\(5\, \text {mTorr} \)) with radio frequencies (operating frequency of \(13.5\, \text {MHz}\)) and a temperature of the plasma of \( 1\, \text {eV}\), it produces deuterons that will then be extracted to the accelerator column, where they will obtain the necessary kinetic energy to collide with the deuterium-rich target and thus generate neutrons.
The initial proposed design parameters consider a deuteron energy of 0.2 to 0.5 MeV, despite the fact that \(D-D\) reaction cross section has a peak between 0.7 and 0.8 MeV, obtaining neutrons with an energy of 2.4 MeV. It is to be considered that for the reaction (2), in general, the neutron energy can be calculated from four-momentum conservation and is given by the expression (Cifuentes (2019)):
where \({E}_{n}\) is the neutron kinetic energy, \({m}_{d}\) is the deuteron mass, \({m}_{n}\) is the neutron mass, \({E}_{d}\) is the deuteron kinetic energy, and \({m}_{B}\) is the mass of the product \(B=\) \(^{3}He\). \(\theta \) is the neutron’s emission angle.
We decided to start with the accelerator column, also in order to acquire experience and sufficient acknowledgement to be able to develop and build the other modules. Additionally, we can strengthen and build collaborations with other international groups and apply for funding.
Results
We present preliminary calculations for the accelerator column. Basically, we need to solve the Poisson and Laplace equations with the corresponding boundary conditions to solve the electric field \(\textbf{E}\) (Leung et al. (1998); Verbeke et al. (1999)).
Figure 2 shows the distance x between the plasma and extraction electrodes as a function of the extraction voltage. By combining the Child-Langmuir and the Boltzmann equations, this relationship is obtained (Csikai (1987)). Clearly, the x distance has an effect on the ion beam profile. By adjusting this distance, a different ion beam configuration—parallel, convergent, or divergent—can be obtained. The choice of ion beam configuration depends on the specific requirements of the fusion experiment or device. Parallel beams allow for simple control and manipulation of the ion trajectories, ensuring a more efficient and homogeneous production of neutrons; convergent beams are typically employed to achieve higher fusion rates and higher neutron yields. Divergent beams are needed when one wants to reduce the beam power density on the target electrode. For instance, for D-D reactions, the deuterium atoms can be evaporated from the target surface if the beam power density is too high. As a result, the neutron yield will be reduced.
The extraction electrode separation distance x is therefore critical to guaranteeing a parallel ion beam for a given extraction voltage (characteristic of the extraction system) and a given ionic density (characteristic of the RF ion source). Upon calibration of these parameters, this profile of ion beam can be obtained.
Boron Geant4 preliminary calculations
The intricate nature of the radiation field associated with BNCT has rendered Monte Carlo simulation an indispensable tool for addressing the low-energy neutron transportation problem. To simulate the passage of neutrons through matter, our group has relied primarily on Geant4 version 10.7 (Agostinelli (2003)), a software widely used in high-energy physics, nuclear physics, and medical physics, developed by an international collaboration of scientists and engineers from various institutions and distributed under the LGPL open-source license. Written in C++, its modular design and variety of implemented models enable it to be used for a vast array of applications, from simple particle tracking to complex simulations of detector systems and radiation therapy treatments.
In order to test the physics models employed in Geant4, we also used MCNP version 6.2 (Werner et al. (2018)), a general-purpose Monte Carlo code for simulating the behavior of particles in complex geometries. The testing consisted of comparing the kinematical and dose distributions (in water) from basic geometries and radiation sources using both Geant4 and MCNP. This allowed us to select the Geant4 physics packages whose results best matched those of MCNP.
Thus, we made use of electromagnetic and high-precision hadronic packages in our Geant4 simulation. In particular, for electromagnetic interactions, we used the G4EmStandardPhysics list, which provides a comprehensive treatment of electromagnetic interactions, including ionization, bremsstrahlung, multiple scattering, and positron annihilation, over a broad range of particle energies and materials. This physics list is based on the classical Bethe-Bloch theory for energy loss, the Goudsmit-Saunderson theory for multiple scattering, and the Bethe-Heitler model for bremsstrahlung processes. Hadronic interactions were implemented through the QGSP-BIC-HP physics list, which combines the QGSP model (Quark-Gluon String Precompound) and the Binary Cascade (BIC) model. For neutrons with energies below 20 MeV, it employs high-precision neutron models and improved cross-section data to account for processes such as elastic and inelastic scattering, capture, and fission. This physics list is dependent on the G4NDL database (Geant4 Collaboration (2021)).
In addition, Geant4 incorporates a model for thermal elastic scattering, which considers the impact of chemical bonds and crystal structures on the scattering process of neutrons by nuclei in materials such as water and polyethylene, particularly at low energies. The importance of this lies in the fact that the scattering characteristics of a substance may exhibit variability based on its molecular or crystalline configuration. For example, the scattering cross section of a water molecule differs from that of a single hydrogen or oxygen nucleus because the two nuclei in the molecule are bonded together. To account for the aforementioned, a special thermal scattering data set and model must be incorporated for neutron energies below 4 eV. This enhances the agreement between Geant4 and MCNP results (i.e., dose, fluence) at low neutron energies (Garny et al. (2009)).
The simulations we have developed encompass regular-shaped targets composed of tissue with varying concentrations of \(^{10}\)B. The neutron sources consist of ideal beams assumed to be monodirectional and monoenergetic. Two different sources are independently implemented: a source of thermal neutrons with energy of 0.025 eV and a source of epithermal neutrons, defined as neutrons with energies between 0.4 eV and 10 keV. Since the probability of \(^{10}\)B capturing a neutron decreases with increasing neutron energy, low-energy (thermal) neutrons have a higher probability of capture than high-energy (epithermal) neutrons, resulting in a higher yield for the boron neutron capture reaction. In contrast, epithermal neutrons have a longer range in tissue and can penetrate deeper into the human body than thermal neutrons. This characteristic renders epithermal neutrons more appropriate for the treatment of tumors that are located at greater depths. To assess the impact of both neutron sources on the dose distribution, simulations were conducted with each.
Results
It can be observed that the radiation field in BNCT is comprised not only of thermal (or epithermal) neutrons but also of \(\alpha \) and \(^7\)Li from \(^{10}\)B neutron capture reactions, photons from \(^1\)H(n, \(\gamma \))\(^2\)H reactions, protons from \(^1\)H(n, n\(^\prime \))\(^1\)H and \(^{14}\)N(n, p)\(^{14}\)C reactions, as well as \(^{14}\)C, and other heavy charged particles. When estimating the absorbed dose, it is necessary to differentiate between dose associated only with \(^{10}\)B, i.e., dose from \(\alpha \) particles and \(^7\)Li nuclei (termed boron dose) and dose resulting from reactions with tissue constituents, i.e., dose mainly from \(\gamma \), p, and \(^{14}\)C (termed non-boron dose).
The simulation is based on a 10-cm-long, 5-cm-wide cylinder containing tissue with concentrations of 35, 50, and 100 ppm of \(^{10}\)B. For thermal neutrons, an energy of 0.025 eV was used. For epithermal neutrons, energies of 1 eV, 10 eV, 100 eV, 1 keV, and 10 keV were implemented. Figure 3 shows the total dose and the boron dose calculated in Geant4 by using thermal neutrons and the lower-energy epithermal neutrons (1 eV). As can be seen, the increasing concentration yields a higher dose only up to about 5 cm. Beyond that, there is virtually no change in both the total dose and the boron dose. In addition, the maximal boron dose for thermal and epithermal neutrons occur at 0.5 and 1.5 cm inside the patient’s body, respectively. Both decrease by approximately two orders of magnitude beyond 8 cm. With higher-energy epithermal neutrons (10 eV - 10 keV), the maximum boron dose occurs at a depth of roughly 3.0 cm for 10 keV, and the maximum depth before the dose decreases by two orders of magnitude is about 10 cm. These results indicate that BNCT cannot provide effective treatment for deep-seated tumors located at a distance of 10 cm or longer.
Concluding remarks
In this work, we present some of the achievements of the NCT initiative in Colombia. In the first place, the simulations of the nuclear reaction via Geant4 are completely feasible, despite some difficulties due to the completeness of the physics libraries regarding the required energy scale of the different intermediate and final states. Secondly, the preliminary design of the accelerator column shows a high degree of similarity with respect to the developments at the Lawrence Berkeley National Laboratory (LBNL) at the University of California, Berkeley, in the USA. At this point, it is of great relevance to mention that beyond the similarities between both designs, there are differences, mainly the voltages of acceleration and extraction, which are expected to increase the neutron fluence. Finally, and of great relevance for our young NTC community, in the last years, we have had 8 graduate masters students (in medical physics and engineering masters programs) and 10 physics bachelors, slowly generating the necessary critical mass of researchers for the future. A group of the master students have focused their research in a first approach to the compact neutron generator and some of the problems associated with it, writing their thesis on the following: Preliminary evaluation of the acceleration of D in a compact high-flux D-D neutron generator (Cifuentes (2019)), Preliminary dose calculation in boron neutron capture therapy using removal diffusion theory (Cruz (2019)), Preliminary evaluation of neutron moderation in a high flux compact D-D generator (Velásquez (2019)), Preliminary algorithm for calculating neutron flux and dose for neutron capture therapy by implementing the Boltzmann lattice method (Luna (2019)), and Computational approach to sterilization of the human amniotic membrane the via Geant4 using ionizing radiation (Pabón (2017)). The undergrade students have worked on the following: Characterization of the interaction of neutral ionizing radiation at the cellular level using a computational simulation with Geant4 (Dominguez (2021)), Computational approximation through Geant4 of the nuclear reaction of neutron capture by hydrogen present in biological cells (Rodríguez (2021)), Computational evaluation of the structural dynamics of a biomolecule, after its interaction with charged particles (Rubio (2020)), Computational study of the structural dynamics of DNA, after its interaction with ionizing radiation (Salazar (2020)), Characterization of the neutron capture reaction by \(^{16}\)O (Sanabria (2022)), Computational evaluation of the microbiological load in biomembranes under treatment with ionizing radiation (Páez (2023)), Cancer: a biophysical look through the cell membrane (Ortega (2021)), Computational approximation via Geant4 of the interaction of \(^7\)Li from neutron capture in biological cells (Medina (2019)), and Computational approximation of the interaction of gamma radiation from neutron capture in biomolecules through Geant4 (Tellez (2019)). In the last years, we have been building the technical-scientific infrastructure necessary to address the problems of the generation and application of neutron radiation to biophysical systems in our country.
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Code Availability
The code associated with this study is available from the corresponding author upon reasonable request.
References
Agostinelli S et al (2003) Geant4-a simulation toolkit. Nuclear instruments and methods in physics research A 506:250–303
Bavarnegin E, Kasesaz Y, Wagner FM (2017) Neutron beams implemented at nuclear research. IOP Publishing for Sissa Medialab
Chadwick J (1932) The existence of a neutron. Proc. R. Soc. Lond. A. 136:692–708. https://doi.org/10.1098/rspa.1932.0112
Cifuentes JA (2019) Evaluación preliminar de la aceleración de D en un generador de neutrones D-D compacto de alto flujo. Preliminary evaluation of the acceleration of D in a compact high-flux D-D neutron generator. Master Thesis, Pontificia Universidad Javeriana 10.11144/Javeriana. 10554.44078 http://hdl.handle.net/10554/44078 Accessed 15 March 2023
Cruz YM (2019) Cálculo preliminar de dosis en la terapia por captura neutrónica del boro empleando teoria de difusión y remoción. Master Thesis, Pontificia Universidad Javeriana https://doi.org/10.11144/Javeriana.10554.4407https://repository.javeriana.edu.co/handle/10554/44077 Accessed 15 March 2023
Csikai J (1987) Handbook of fast neutron generator (1987). CRC Press Inc, Boca Raton, Florida
Dominguez TV (2021) Caracterización de la interacción de radiación ionizante neutra a nivel celular mediante una simulación computacional con Geant4. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/26632 Accessed 15 March 2023
Garny S, Leuthold G, Mares V, Paretzke HG, Rühm W (2009) GEANT4 transport calculations for neutrons and photons below 15 MeV. IEEE Transactions On Nuclear Science, Vol. 56, No. 4
Geant4 Collaboration (2021). Guide for physics lists. Geant4, version 10.7. Available at: https://geant4-userdoc.web.cern.ch/UsersGuides/PhysicsListGuide/html/index.htmlhttps://geant4-userdoc.web.cern.ch/UsersGuides/PhysicsListGuide/html/index.html
Hanaoka K, Watabe T, Naka S et al (2014) FBPA PET in boron neutron capture therapy for cancer: prediction of 10B concentration in the tumor and normal tissue in a rat xenograft model. EJNMMI Research 4:1–8
Hosmane NS, Maguire JA, Salt C et al. (2012) Boron and gadolinium neutron capture therapy for cancer treatment. L. E. Feinendegen, World Scientific, EE. UU.: Treatment United States Department of Energy Office of Science
International Atomic Energy Agency (2001) IAEA-TECDOC-1223 Current status of neutron capture therapy. IAEA, Vienna, Austria
Kankaanranta L, Seppälá T, Koivunoro H et al (2012) Boron neutron capture therapy in the treatment of locally recurred head-and-neck cancer: final analysis of a phase I/II trial. Int J Radiat Oncol Biol Phys 82:67–75
Kim J-K, Kim K-O (2009) Current research on accelerator based boron neutron capture therapy in Korea. Nuclear Engineering and Technology 41:531
Kreiner JA, Bergueiroa J, Cartelli D, Baldoa M, Castell W et al (2016) Present status of accelerator-based BNCT. Reports of Practical Oncology & Radiotherapy 21:95–101. https://doi.org/10.1016/j.rpor.2014.11.004
Lawrence EO, Livingston MS (1932) The production of high speed light ions without the use of high voltages. Phys. Rev. 40:19
Leung K-N, Lee Y, Verbeke JM, Vujic J, Williams MD, Wu LK, Zahir N (1998) A sealed-accelerator-tube neutron generator for boron neutron capture therapy application. Lawrence Berkeley National Laboratory Retrieved from https://digital.library.unt.edu/ark:/67531/metadc895633/
Leung K-N, Reijonen J, Gicquel F, Hahto S, Lou T (2004) Compact neutron generator development and applications. Lawrence Berkeley National Laboratory. Retrieved from https://escholarship.org/uc/item/8fd8f89r
Locher GL (1936) Biological effects and therapeutic possibilities of neutrons. Am J Roentgenol 36:1–13
Luna KA (2019) Algoritmo preliminar de cálculo de flujo y dosis de neutrones para terapia por captura neutrónica mediante la implementación del método de lattice Boltzmann. Master Thesis, Pontificia Universidad Javeriana https://doi.org/10.11144/Javeriana.10554.44601https://repository.javeriana.edu.co/handle/10554/44601 Accessed 15 March 2023
Medina RS (2019) Aproximación computacional a través de Geant4 de la interacción de 7Li procedentes de la captura de neutrones en células biológicas. Trabajo de grado, Universidad Distrital Francisco José de Caldashttps://repository.udistrital.edu.co/handle/11349/16091 Accessed 15 March 2023
Moghaddasi L, Bezak E (2017) Development of an integrated Monte Carlo model for glioblastoma multiforme treated with boron neutron capture Therapy. Scientific Reports 7:7069
Ortega LC (2021) El cáncer: una mirada biofísica a través de la membrana celular. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/29648 Accessed 15 March 2023
Pabón YA (2017) Aproximación computacional vía Geant4 a la esterilización de membranas amnióticas humanas usando radiación ionizante. Master Thesis, Pontificia Universidad Javeriana https://doi.org/10.11144/Javeriana.10554.38500https://repository.javeriana.edu.co/handle/10554/38500 Accessed 15 March 2023
Páez M (2020) Evaluación computacional de la carga microbiológica en biomembranas bajo tratamiento con radiación ionizante. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/23657 Accessed 15 March 2023
Rodríguez DA (2021) Aproximación computacional a través de Geant4 de la reacción nuclear de la captura neutrónica por hidrógeno presente en las células biológicas. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/26373 Accessed 15 March 2023
Rubio MA (2020) Evaluación computacional de la dinámica estructural de una biomolécula, luego de su interacción con partículas cargadas. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/23651Accessed 15 March 2023
Salazar JE (2020) Estudio computacional de la dinámica estructural del ADN, posterior a su interacción con radiación ionizante. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/23650 Accessed 15 March 2023
Sanabria LS (2022) Caracterización de la reacción de captura neutrónica por \(^{16}\)O. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/30492Accessed 15 March 2023
Sauerwein WAG, Moss R, Wittig A, Nakagawa Y (2012) Neutron capture therapy principles and applications. Springer, Heidelberg New York Dordrecht London. https://doi.org/10.1007/978-3-642-31334-9
Taylor HJ, Goldhaber M (1935) Detection of nuclear disintegration in a photographic emulsion. Nature 135:341. https://doi.org/10.1038/135341a0
Tellez DA (2019) Aproximación computacional de la interacción de la radiación gamma procedente de la captura de neutrones en biomoléculas a través de Geant4. Trabajo de grado, Universidad Distrital Francisco José de Caldas https://repository.udistrital.edu.co/handle/11349/16093 Accessed 15 March 2023
Velásquez LY (2019) Evaluación preliminar de la moderación de neutrones en un generador D-D compacto de alto flujo. Master Thesis, Pontificia Universidad Javeriana 10.11144/Javeriana. 10554.43981 https://repository.javeriana.edu.co/handle/10554/43981 Accessed 15 March 2023
Verbeke JM (2000) Development of high-intensity D-D and D-T neutron sources and neutron filters for medical and industrial applications. Dissertation, University of California, Berkeley
Verbeke JM, Lee Y, Leung K-N, Vujic J, Williams MD, Wu LK, Zahir N (1999). Neutron tube design study for boron neutron capture therapy application. https://doi.org/10.1109/PAC.1999.792761
Verbeke JM, Vujic JL, Leung K-N (2000) Neutron beam optimization for boron neutron capture therapy using the D-D and D-T high-energy neutron sources. Nuclear Technology 129:257–278. 10.13182/Nt00-A3061
Werner CJ et al. (2018) MCNP6.2 release notes. Los Alamos National Laboratory, report LA-UR-18-20808
Acknowledgements
The computations were performed at the Computational Centers of the Pontificia Universidad Javeriana and the Universidad Distrital Francisco José de Caldas, respectively.
Funding
Open Access funding provided by Colombia Consortium. This study was funded by the internal budgets of the Faculty of Sciences of the Pontificia Universidad Javeriana and the Faculty of Sciences and Education of the Universidad Distrital Francisco José de Caldas, respectively.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethics approval
This article does not contain any studies with animals performed by any of the authors.
Consent to participate
Not applicable
Consent for publication
Not applicable
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.