Introduction

Chest pain is a common symptom that may be caused by obstructive coronary artery disease (CAD) and requires risk stratification to assess the probability of CAD [1]. Risk algorithms have been developed based on combinations of risk factors [2, 3]. However, these models tend to overestimate the prevalence of CAD [4], and are based on population calculations rather than a direct assessment of the atherosclerotic process within an individual. Diagnostic testing with exercise electrocardiography (X-ECG) is considered to be highly discriminative [5], however is often inconclusive. Alternative tests using pharmacological stress are usually not immediately available. Computed tomography (CT) is expanding in the workup [1], using coronary calcium scoring (CCS) [6] and computed tomographic angiography (CTA) [7]. However, there are associated disadvantages such as costs, radiation exposure and administration of contrast agent [8]. Therefore, a better discrimination of patients at low risk of clinically relevant CAD will facilitate more efficient use of subsequent diagnostics.

Endothelial dysfunction precedes and contributes to the atherosclerotic disease process. Peripheral arterial tonometry (PAT) has emerged as an easy, noninvasive test to study endothelial function at the fingertip [9, 10]. From one single PAT measurement both the reactive hyperaemia index (RHI), indicating endothelium-dependent vasodilation [11], and the augmentation index (AIx), indicating arterial stiffness [12], can be derived. RHI and AIx have shown to be altered in the presence of CAD [1215], and can be used in CAD risk stratification [16]. However, although PAT appears promising in research settings, validation in the clinical setting beside conventional measures has only been limited [11]. Therefore, the objective of this cross-sectional study was to assess the applicability of PAT to detect low risk of clinically relevant CAD in unselected patients visiting a rapid-access outpatient chest pain clinic.

Methods

Study population

From September 2009 to February 2010, 93 consecutive patients with new onset stable chest pain without evidence of ongoing ischaemia and no prior history of CAD gave written consent to undergo finger plethysmography to measure PAT at the same time as their chest pain evaluation, after study approval by the Medical Ethics Committee. The sample size was comparable with previous PAT validation studies [11, 12, 16], and sufficiently large to observe discriminating tendencies [17]. There were no exclusion criteria. All patients were scheduled to undergo conventional diagnostics. Based on cut-off values of these diagnostics, patients at low risk of clinically relevant CAD were identified. This was verified by evaluating revascularised patients by percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) for up to 1 year.

Risk profiling

Cardiovascular risk factors were summarised using the HeartScore risk algorithm [3] to assess the risk of 10-year mortality of CAD and the Diamond and Forrester model (DF) [2, 4] to assess the pretest probability of CAD.

Exercise electrocardiography

X-ECG was performed by standardised protocol [5]. A non-diagnostic result was defined as discontinuation without evidence of myocardial ischaemia before reaching 85 % of the target heart rate. Results were described as being non-ischaemic, inconclusive or ischaemic. Only non-ischaemic and ischaemic groups were taken into comparative anal.

Cardiac computed tomography

A non-enhanced CT scan was performed to assess the amount of coronary calcium, followed by a contrast-enhanced scan to assess plaque burden and presence of stenotic CAD. Image acquisition was conducted using a 128-slice dual-source CT (Siemens Flash, Forchheim, Germany). Coronary arteries were quantitatively evaluated per coronary segment for presence of atherosclerotic plaque and > 50 % stenosis [7]. CCS and total number of plaques and stenoses per patient were included in the analysis.

Peripheral arterial tonometry

The PAT response was measured with the EndoPAT 2000 device (Itamar Medical Ltd., Caesarea, Israel), according to a standardised protocol allowing simultaneous determination of both RHI and AIx. An index of pulse wave amplitude at rest and during reactive hyperaemia resulted in RHI, a measure of endothelium-dependent vasodilation [911, 13, 16]. Augmentation of the central pulse pressure allowed determination of AIx, representing endothelium-dependent arterial stiffness [12, 18].

Statistical analysis

Summary data are presented as numbers (proportion) or expressed as mean ± standard deviation or median (interquartile range). In case of non-normal distribution, data were logarithmically transformed before analysis. Correlations between RHI, AIx and conventional diagnostics were analysed using Pearson’s correlation coefficient. Differences between two groups were assessed by t-testing. The predictive value of RHI and AIx for revascularisation was analysed using logistic regression and described as odds ratio (OR) with corresponding 95 % confidence interval (CI). Two-tailed p < 0.05 was considered significant.

Results

Conventional diagnostic characteristics

Overall, patients were middle aged with equal distribution between genders (Table 1). None had a history of CAD, but cardiovascular risk factors were abundant and three quarters used cardiovascular medication. In all, conventional diagnostics besides PAT were performed to examine clinically relevant CAD (Table 2). This allowed us to examine correlations between PAT and conventional diagnostics, as well as sub-group analysis for these outcomes and prediction of revascularisation within 1 year.

Table 1 Patient characteristics
Table 2 Diagnostic characteristics

Digital pulse arterial tonometry testing

With regard to risk algorithms, RHI correlated weakly with HeartScore (r = − 0.21, p = 0.05, Fig. 1a), whereas AIx did not (r = 0.15, p = NS, Fig. 1b). Surprisingly, RHI did not correlate with DF (r = 0.05, p = NS, Fig. 1c), whereas AIx did modestly (r = 0.26, p < 0.05, Fig. 1d). With regard to CT parameters, no significant correlations between RHI and CCS (r = − 0.09, p = NS), plaque (r = − 0.09, p = NS, Fig. 1e) or stenosis (r = − 0.08, p = NS) were found. Also no significant associations between AIx and CCS (r = 0.06, p = NS), plaque (r = 0.11, p = NS, Fig. 1f) or stenosis (r = 0.03, p = NS) were observed.

Fig. 1
figure 1

Correlation graphs of reactive hyperaemia index (RHI) (panels a, c, e) and augmentation index (AIx) (panels b, d, f) with HeartScore (panels a, b), Diamond and Forrester pretest probability (DF) (panels c, d) and total amount of plaque assessed by computed tomographic angiography (CTA) (panels e, f). Regression equation and R2 correlation coefficient are depicted per panel. Significant associations were observed between RHI and HeartScore as well as between AIx and DF, *P ≤ 0.05

To analyse low risk of clinically relevant CAD more specifically, patients were divided into low or intermediate-to-high risk groups based on the outcomes of risk scores, X-ECG and CT. According to the risk algorithms, patients at low risk (n = 18; defined as low risk of both DF and HeartScore outcomes) showed similar RHI and AIx values as compared with intermediate-to-high risk (n = 72; defined as intermediate-to-high risk of DF or HeartScore outcome), respectively (RHI: 1.98 (0.67) vs 1.94 (0.78); AIx: 0.00 (21) vs 5.0 (25); all p = NS; Fig. 2a, b). According to X-ECG results, low risk (n = 43; defined as a negative X-ECG outcome) also did not significantly differ from high risk (n = 7; defined as a positive outcome), respectively (RHI: 1.97 (0.72) vs 1.58 (0.61); AIx: − 0.50 (19) vs 8.0 (29); all p = NS). According to CT outcomes, low risk (n = 20; defined as absence of calcium, plaque and stenosis) resembled intermediate-to-high risk (n = 68; defined as presence of calcium, plaque or stenosis) (RHI: 1.99 (0.58) vs 1.89 (0.82); AIx: − 2.0 (24) vs 4.0 (25); all p = NS; Fig. 2c, d).

Fig. 2
figure 2

Differences of reactive hyperaemia index (RHI) (panels a, c) and augmentation index (AIx) (panels b, d) between patients at low and intermediate-to-high risk of clinically relevant CAD based on the combined outcome of risk scores (a, b), and CCS and CTA assessed plaque and stenosis (c, d). Horizontal bars depict the median value. No significant differences between the groups were observed. RF risk factors, X-ECG exercise ECG, CT computed tomography, low low risk, int-hi intermediate-to-high risk

Finally, both RHI and AIx could not predict revascularisation within 1 year (RHI: OR 1.42, CI 0.65–3.1; AIx: OR 1.02, CI 0.98–1.05). Although RHI was lower in the revascularised group, this was not significantly different (revascularisation + (n = 11) vs revascularisation − (n = 79): 1.94 (1.06) vs 1.96 (0.70), p = NS; Fig. 3a). Also AIx showed a tendency towards an altered response in the revascularised group, however again not statistically significant (revascularisation + (n = 11) vs revascularisation − (n = 81): 4.0 (27) vs 2.0 (23), p = NS; Fig. 3b). This is in contrast to conventional diagnostics: the revascularised group (n = 7) showed significantly more ischaemic X-ECG outcomes than the non-revascularised group (n = 46) (0.71 ± 0.18 vs 0.09 ± 0.04; p < 0.01); CCS showed a modest prediction (OR 1.01, CI 1.00–1.03), whereas CTA-assessed plaque (OR 1.11, CI 1.05–1.17) and stenosis (OR 2.8, CI 1.60–4.8) showed strong predictions of revascularisation.

Fig. 3
figure 3

Differences of reactive hyperaemia index (RHI) (panel a) and augmentation index (AIx) (panel b) between patients with and without revascularisation up to 1 year after PAT measurement. Horizontal bars depict the median value. No significant differences between the groups were observed. Revasc − no revascularisation; Revasc + revascularisation

Discussion

The present study examined the applicability of PAT-derived RHI and AIx to identify patients at low risk of clinically relevant CAD. The most important findings were (i) that although RHI and AIx correlated weakly with CAD risk estimates, (ii) both RHI and AIx were not related with X-ECG or CT-imaged parameters. (iii) Most importantly, low risk based on conventional diagnostics showed non-discriminative RHI and AIx outcomes. (iv) Finally, both RHI and AIx failed to predict revascularisation within 1 year.

Clinical applicability of PAT

(i) We confirmed the modest relation of RHI with traditional risk factors, as reported previously [13]. AIx showed a weak correlation with the pretest probability of CAD. Patvardhan et al. [12] reported a strong association between AIx and age, most likely the basis for this correlation. (ii) No significant differences in either RHI or AIx were observed based on X-ECG outcome. This is remarkable since X-ECG is considered to be highly discriminative in patients at risk of obstructive CAD [5], and also RHI has shown to be able to discriminate between presence or absence of CAD [11]. Indeed, ischaemic X-ECG outcomes were more frequently present in revascularised patients of the present study whereas RHI was non-discriminative, making an independent relation likely. In addition, RHI and AIx did not significantly correlate with CCS, in contrast to a prior study of selected patients [19]. Han et al. [20] also showed no association between coronary endothelial dysfunction and calcification, reflecting that both can represent separate disease stages. In addition, brachial AIx was not independently associated with CCS [21], supporting our results. Indeed, other vascular function tests have previously indicated that endothelial dysfunction may represent an independent response in the progression of CAD, whereas a relation with the development of atherosclerosis exists [2226]. RHI and AIx were not significantly associated with CTA-imaged plaque or stenosis. This is contrary to previous studies with imaged CAD describing specific subgroups with proven CAD [11, 12], diabetes [14], or women [15] although the presence of CAD was not verified with CTA in any of them. (iii) Also, RHI and AIx were not able to differentiate low risk of clinically relevant CAD, in contrast to results in selected populations [11, 12, 16], complicating comparison with our unselected population. (iv) Finally, RHI and AIx failed to predict revascularisation within 1 year, contrary to Rubinshtein, who showed that RHI independently predicted revascularisation [27]. Also radial AIx predicted revascularisation [28], although for digital AIx no such studies exist to our knowledge. However, again selected patients were evaluated with adverse events occurring at long-term follow-up, which is difficult to compare with our 1-year evaluation. Indeed, patient selection may strongly influence outcome because specific risk factors have additional effects on the measurement itself besides on the CAD process, as highlighted by the study of Gargiulo [14].

Conclusions

In spite of the pathophysiological basis of endothelial dysfunction in CAD and the promising results with PAT in selected populations under controlled conditions, we found no evidence to support PAT as a diagnostic tool to detect low risk of clinically relevant CAD in an unselected outpatient population.