Introduction

The construction and maintenance of marine facilities is one of the key points to the sustainable development of the ocean. Metals are among the most important components of marine facilities. However, they are prone to pitting corrosion in Cl-enriched environments, threatening the safety of the facility. Thus, effective corrosion detection methods and maintenance measures are needed. The life-cycle maintenance of marine engineering facilities is of great significance to the economy and society, and corrosion detection is the basis of this maintenance.

Stainless steel (SS) is widely used in island facilities and military equipment such as ships [1, 2]. However, the atmospheric corrosion of SSs is an important factor restricting their applications. Therefore, developing an electrochemical method to detect the corrosion type and corrosion degree of metal materials is necessary. The electrochemical noise (EN) technique has been widely used in atmospheric corrosion detection because its detection equipment is simple and portable and can be used for remote continuous monitoring [3]. The application of EN technique requires proper data analysis [4,5,6], and the establishment of a reliable electrode system in the atmospheric environment [7, 8]. The data analysis of EN can represent the characteristic parameters of the corrosion type and corrosion degree of metal materials through time domain analysis, frequency domain analysis, and time–frequency analysis [9, 10].

Researchers around the world have applied the EN technique for corrosion detection. Sarmiento et al. [11] used EN to study the corrosion behavior of 316L SS at different temperatures in LiBr  + ethylene glycol + H2O solution and obtained the surface conditions and electrochemical behavior under corrosion conditions by EN measurement. Xia et al. [12] used EN to monitor the atmospheric corrosion of Q235B steel, quantified the corrosion rate using statistical parameters and frequency domain analysis, and evaluated the reliability of EN measurement coupled with electrochemical impedance spectroscopy. Pujar et al. [13] verified that EN could evaluate the intergranular corrosion of 316 SS. Tang et al. [14] studied the influence of surface roughness on the pitting behavior of 2205 DSS in a Cl environment by EN measurement and morphological observation. However, some of the mathematical parameters lack strict physical meaning; thus, it is very important to conduct electrochemical equivalent circuit (EEC) analysis in order to further study the physical meaning of EN feature parameters and influencing factors. In addition, the corrosion of metal materials in the solution environment has been well documented, but the corrosion in the atmospheric environment has rarely been investigated. As the solution resistance varies greatly with different environments and times due to humidity, pollutant composition, and other factors, the detection results will be largely affected. Therefore, establishing an EEC model for EN data analysis of metal corrosion in the atmospheric environment is necessary. Moreover, the influence of solution resistance on EN characteristic parameters, such as the power spectral density (PSD) of potential noise, the PSD of current noise, noise impedance, and noise resistance also needs to be examined.

This study investigated the atmospheric corrosion of 304 SS and 2205 DSS using EN in a simulated marine atmosphere, clarified the factors affecting the EN characteristic parameters, and obtained the corrosion rate based on the Thevenin EEC model. Atmospheric corrosion probes of 304 SS and 2205 DSS were developed, and EN detection was performed under a salt spray containing Cl in a dry–wet cycle test. The original EN data were analyzed in time and frequency domains. In addition to analyzing the surface morphology, the corrosion degrees of 304 and 2205 SSs under the same atmospheric environment were evaluated.

Experimental Procedures

Electrochemical Probes

Two electrochemical probes were used to study the atmospheric corrosion of 304 and 2205 SSs. One of their schematic diagrams is shown in Fig. 1. The probe incorporates three identical electrodes made by 304 or 2205 SS, with an exposure area of 0.75 cm2 for each electrode. This type of setup is called a symmetrical electrode system [15,16,17,18]. The experimental materials are 304 SS and 2205 DSS. Their chemical components are presented in Table 1, and their microstructures are shown in Fig. 2. The 304 SS is austenitic, whereas the 2205 DSS is composed of ferrite and austenite.

Fig. 1
figure 1

Schematic diagram of atmospheric corrosion probe and the electric schematic diagram for electrochemical noise measurement

Table 1 Chemical compositions of 304 SS and 2205 DSS (wt%)
Fig. 2
figure 2

Microstructures of a 304 SS and b 2205 DSS

To isolate the three electrodes, a gap of 0.2 mm existed between the adjacent electrodes [12, 19], as shown in Fig. 1. The three electrodes were embedded in an epoxy resin. The working face was polished with waterproof abrasive papers of 400#, 800#, 1200#, 1500#, and 2000#, and the non-exposed area of each electrode was welded to a copper wire, to connect the electrochemical measurement system.

EN Measurement System and Experiment

The two 304 SS and 2205 DSS probes were placed in a salt spray environment, which was filled with atomized 5% NaCl solution to simulate the marine atmosphere. Each probe surface was tilted 45° to the horizontal plane for the dry–wet cycle test. One cycle period was 4 h, including 2 h wetting time with experimental temperature of 50 °C and 2 h drying time with experimental temperature of 35 °C.

The EN measurement was conducted by a system composed of the FieldPoint analog input module CFP-AI-118 NI, a ZF3 potentiometer, and a Compact FieldPoint (CFP) industrial controller module (Fig. 3). The zero resistance ammeter (ZRA) mode was adopted for detection, and the sampling frequency was 2 Hz [6, 20]. The DC components in all the EN data were removed using a quintic polynomial fitting [21,22,23].

Fig. 3
figure 3

Electrochemical noise detection system based on the FieldPoint analog input module cFP-AI-118 NI, a ZF3 potentiometer, and a Compact FieldPoint industrial controller module

Electrochemical Equivalent Circuit Model

The Thevenin EEC proposed by Bertocci et al. [24] is one of the most commonly used methods for modeling EN sources. First, the effectiveness of the electrochemical parameters measured by EN in the ZRA mode to test the SS corrosion degree should be determined. The electrochemical parameters include potential standard deviation, current standard deviation, and noise resistance [25, 26].

The atmospheric corrosion detection probes for EN measurement at the 304 SS and 2205 DSS consisted of three identical SS electrodes, all of which generate potential or current noise. The EEC models are shown in Fig. 4a, b. In the figures, WE1 in the middle denotes the working electrode, WE2 on the right denotes the counter electrode, and RE on the left is the reference electrode.

Fig. 4
figure 4

Equivalent circuit model of the atmospheric corrosion detection probe with three identical electrodes used in EN test. a Equivalent circuit for current noise and b equivalent circuit for potential noise

Since the three electrodes are nominally identical, the noise impedance Rsn(f) is equal to \({}^{\sqrt 3 }\left| {Z(f)} \right|\) [24, 25], and the noise resistance Rn is equal to the low frequency limit of Rsn(f) for some assumptions [24]. Therefore, Rn and Rsn(f) are related only to the electrode impedance modulus |Z(f)| and can be used as indicators to evaluate the atmospheric corrosion degree.

Results and Discussion

EN Time Domain Analysis

Figures 5 and 6 show the current noise and potential noise after removing the DC component for the 304 SS and 2205 DSS, respectively, during dry–wet cycle EN measurements. The potential standard deviation, current standard deviation, and noise resistance of the two SSs are presented in Tables 2 and 3, respectively. The results showed that at the beginning, the current noise fluctuation of the two SSs was small (Figs. 5a, 6a), indicating that the passive film on the SS surface was intact, and the corrosion rate was slow. The potential noise fluctuated greatly, possibly because the surface state of the SS was unstable after a brief exposure to the Cl-containing atmosphere.

Fig. 5
figure 5

Current noise and potential noise of 304 SS. a The third cycle, b the 13th cycle, and c the 42nd cycle

Fig. 6
figure 6

Current noise and potential noise of 2205 DSS. a The third cycle, b the 15th cycle, and c the 44th cycle

Table 2 Fitted electrochemical parameters of EN detection for 304 SS
Table 3 Fitted electrochemical parameters of EN detection for 2205 DSS

As the number of dry–wet cycles increased (Figs. 5b, 6b), Cl kept depositing on the SS surface; a stable state was gradually reached, and the potential standard deviation decreased. At this stage, synchronous transient peaks began to appear on the potential and current noise curves, the standard deviation of current increased, and the noise resistance decreased. This is due to Cl-induced corrosion, which led to the rupture and repair of the passive film on the SS surface, pitting initiation, and corrosion rate increase. The results show that the pitting initiation on the SS surface did not propagate all the time; it can repassivate. At the initial stage when the passive film was damaged, the effect on the stability of the passive film was little. The pitting initiation in each dry–wet cycle was random and characterized by low probability. The pits can also be repaired again.

After over 40 dry–wet cycle tests, the fluctuations of current noise and potential noise on the 304 SS (Fig. 5c) increased, and a large number of transient peaks appeared simultaneously. At the same time, the standard deviations of current and potential increased, indicating that the damage degree of the passive film further increased, the probability of pitting increased, and the corrosion rate increased. However, the fluctuations of current noise and potential noise on the 2205 DSS (Fig. 6c) were still lower than those on the 304 SS. Moreover, the standard deviation of current, the standard deviation of potential, and the noise resistance were not significantly changed, which indicates that the passive film on the 2205 DSS surface was still complete, and the resistance to Cl corrosion was more than that of the 304 SS.

The noise resistances of 304 SS and 2205 DSS during the dry–wet cycle EN measurement are depicted in Fig. 7. The noise resistance is only related to the impedance modulus of the electrode and can be used as an indicator to evaluate the atmospheric corrosion degree. At the beginning of the dry–wet cycle test, both the 304 SS and 2205 DSS featured high noise resistance, indicating that the passive film on the SS surface was complete, strong resistance to Cl-induced corrosion, and a low corrosion rate. As the number of dry–wet cycles increased, the noise resistances of both SSs were reduced, indicating that the passive film broke and pitting began to occur. However, the resistance did not decrease steadily but alternated between decreasing and increasing, which also proved that the SS passive film will be repaired after being broken, and the pitting will still be passivated during the next dry–wet cycle.

Fig. 7
figure 7

Noise resistances of 304 SS and 2205 DSS EN detection

Although the noise resistances of the 304 SS and 2205 DSS maintained a high order of magnitude in the experiments, indicating a better corrosion resistance and lower corrosion rate, they both decreased with increasing the number of dry–wet cycles. It shows that even at the pitting initiation stage, pits can be repassivated, but continuous pitting still has a destructive effect on the passive film. As this minor damage accumulated, the SS gradually became less resistant to Cl-induced corrosion, and the corrosion rate increased, eventually leading to the failure of the SS.

The noise resistances of 304 SS and 2205 DSS are about 105 and 106 Ω, respectively. Even though the noise resistance is reduced overall, the latter is still an order of magnitude higher than the former, indicating that the 2205 DSS has a better corrosion resistance. The high corrosion resistance of DSS is due to its high-Cr content and a large amount of Mo, Ni, and N elements. Chromium can form a protective passive film of Cr–O/OH on the DSS surface. The synergistic effect between Cr and Mo–O/OH improves the DSS pitting stability. Nitrogen acts as a kind of interstitial solid solution element to enhance the DSS tensile properties.

Frequency Domain Analysis

Figure 8 depicts the frequency domain analysis results of the 304 SS EN data as shown in Fig. 5. As the number of dry–wet cycles increased, the PSDs of potential noise and noise impedances decreased, while the PSDs of current noise increased. This indicates that with the increase in pitting corrosion on the 304 SS surface, the passive film was increasingly destroyed, the SS corrosion resistance decreased, and the corrosion rate increased as well.

Fig. 8
figure 8

Frequency domain analysis results of the 304 SS EN data as shown in Fig. 5. a Power spectral density of potential noise, b power spectral density of current noise, and c noise impedance

Figure 9 shows the frequency domain analysis results of the 2205 DSS EN data as shown in Fig. 6. As the number of dry–wet cycles increased, the PSDs of potential noise and noise impedances decreased, while the PSDs of current noise increased and then tended to stabilize. This indicates that with the development of the experiment, pitting corrosion occurred on the 2205 DSS surface, the passive film broke down, and the SS corrosion resistance decreased. However, the passive film on the 2205 DSS was stable and complete in the initial exposure stage. The 2205 DSS exhibited a better corrosion resistance compared with the 304 SS under the same experimental conditions.

Fig. 9
figure 9

Frequency domain analysis results of the 2205 DSS EN data as shown in Fig. 6. a Power spectral density of potential noise, b power spectral density of current noise, and c noise impedance

Morphology Analysis

A KEYENCE VHX-2000C ultra-depth 3D microscope was used to observe the surface morphology of corroded samples. Figure 10 shows the surface morphology of a pitting location of the 304 SS after 25 and 60 dry–wet cycles. After 25 cycles, the pits were very small and had a depth of less than 5 µm, but many corrosion products occurred around the pits. After 60 cycles, the morphology of the pitting location changed little, and the pitting did not expand in depth or radius. Figure 10e shows the microscopic surface morphology under a 3D microscope after 60 cycles. It can be seen that a large number of micron-scale pits appeared on the SS surface. This confirms that the rupture and pitting initiation of the passivated film on the SS surface were random. The location of each pitting may not be the same as that of the last one. The non-expansion of the pitting hole also indicates that the passive film can be repaired after the rupture, and the pitting location still featured good corrosion resistance after the passivation.

Fig. 10
figure 10

Surface morphology of 304 SS. a 2D image after 25 cycles, b 3D image after 25 cycles, c 2D image after 60 cycles, d 3D image after 60 cycles, and e enlarged 2D image after 60 cycles

Figure 11 shows the surface morphology of a pitting location of the 2205 DSS after 25 and 60 dry–wet cycles. Only a few corrosion products covered the surface, and the pits were too small to be observed in the figure. Moreover, most areas of the sample surface were smooth, with only a few tiny pits (Fig. 11c).

Fig. 11
figure 11

Surface morphology of the 2205 DSS. a After 25 cycles, b, and c two different areas after 60 cycles

After 60 cycles, the macromorphology of 304 SS and 2205 DSS changed little, and the surface was bright. However, using a 3D microscope, a large number of tiny pitting holes could be observed on the 304 SS. It indicates that under normal service conditions, the large number of tiny pits on the 304 SS surface can hardly be noticed, but their existence will significantly reduce the 304 SS corrosion resistance. Therefore, the material should be tested and maintained on time to avoid premature failure. The 2205 DSS surface featured few micro-erosion holes, and the depth and radius of the pitting holes were much smaller than those of the 304 SS. This indicates that the corrosion resistance of 2205 DSS is much better than that of 304 SS under the same working conditions.

Conclusions

In this article, the atmospheric corrosions of 304 SS and 2205 DSS were investigated using the EN technique, and the results are summarized as follows:

  1. (1)

    All three 304 or 2205 SS electrodes in the probes produced current noise and potential noise, which could be detected using the EN technique. When the three electrodes have the same impedance modulus |Z(f)|, then we have \(R_{{{\text{sn}}}} (f) = {}^{\sqrt 3 }\left| {Z(f)} \right|\); thus, Rn and Rsn can be used as indicators to evaluate atmospheric corrosion degree.

  2. (2)

    At the initiation of the dry–wet cycle experiment, the SS passive film was intact, and its dissolution rate was low.

  3. (3)

    As the number of dry–wet cycles increased, Cl was deposited on the SS surface and broke the passive film, pitting was initiated, and the corrosion rate increased. Under the same experimental conditions, the 2205 DSS exhibited better corrosion resistance than the 304 SS.

  4. (4)

    The pitting initiation of the passivated film on the SS surface was random. At the initial stage of the experiment, the pitting location still had good corrosion resistance after the passivation.

  5. (5)

    With the pitting corrosion propagation, the corrosion resistance was persistently reduced for the two SSs.