Abstract
The effect of compressive strength and expansion rate of filler grout on bond behavior of grouted pipe splice is discussed. Three types of grout were designed and utilized to prepare coupler specimens as filler material. The compressive strength ranged from 67.5 to 91.8 MPa. The volume expansion rate changed from -0.023% to -0.037% under airtight curing condition, and from 0.027% to 0.057% under water curing condition, respectively. Based on pullout test, it was found that the bond strength and stiffness of grouted splice both improve with the increment of the expansion rate due to the increased initial confinement. By experimentally measuring the exterior surface transverse strain of grouted sleeve in curing stage, the confinement and its influencing factor on bond performance were derived. The confinement increases nonlinearly with the increment of grout shell thickness and sleeve radial stiffness other than grout expansion rate. The diameter-thickness ratio of sleeve should not exceed 13 to avoid a possible debonding failure at bar-grout interface. Utilizing the calculated confining pressures, the bond strength of the grouted splice was determined and compared with pullout test result, which shows a good agreement.
Similar content being viewed by others
References
Budynas, R. G. (1998). “Advanced strength and applied stress analysis.” Topics From Advanced Mechanics of Materials, WCB/McGraw-Hill, Boston.
Chinese Standard GB50010-2010 (2015). Code for design of concrete structures, China Architecture & Building Press, Beijing, China. (in Chinese)
Comitê Euro-International du Beton (CEB) (1993). CEB-FIP model code 1990, Thomas Telford, London.
Einea, A., Yamane, T., and Tadros, M. K. (1995). “Grout-filled pipe splices for precast concrete construction.” PCI Journal, Vol. 40, No. 1, pp. 82–93, DOI: 10.15554/pcij.01011995.82.93.
Henin, E. and Morcous, G. (2015). “Non-proprietary bar splice sleeve for precast concrete construction.” Engineering Structures, Vol. 83, pp. 154–162, DOI: 10.1016/j.engstruct.2014.10.045.
Hosseini, S. J. A. and Rahman, A. B. A. (2016). “Effects of spiral confinement to the bond behavior of deformed reinforcement bars subjected to axial tension.” Engineering Structures, Vol. 112, pp. 1–13, DOI: 10.1016/j.engstruct.2015.12.038.
Jiang, S. C. and Wang, Z. (2013). “Theoretical approach for initial stresses analysis in prestressed grouted tube-to-sleeve connections.” Engineering Mechanics, Vol. 4, pp. 301–309, DOI: 10.6052/j.issn.1000-4750.2011.12.0870.
Kim, H. (2012). “Bond strength of mortar-filled steel pipe splices reflecting confining effect.” Journal of Asian Architecture and Building Engineering, Vol. 11, No. 1, pp. 125–132, DOI: 10.3130/jaabe.11.125.
Ling, J. H., Abd. Rahman, A. B., Ibrahim, I. S., and Hamid, Z. A. (2012). “Behavior of grouted pipe splice under incremental tensile load.” Construction and Building Materials, Vol. 33, pp. 90–98, DOI: 10.1016/j.engstruct.2015.12.023.
Ling, J. H., Abd. Rahman, A. B., and Ibrahim, I. S. (2014). “Feasibility study of grouted splice connector under tensile load.” Construction and Building Materials, Vol. 50, pp. 530–539, DOI: 10.1016/j.conbuildmat.2013.10.010.
Sayadi, A. A., Rahman, A. B. A., Jumaat, M. Z. B., Alengaram, U. J., and Ahmad, S. (2014). “The relationship between interlocking mechanism and bond strength in elastic and inelastic segment of splice sleeve.” Construction and Building Materials, Vol. 55, pp. 227–237, DOI: 10.1016/j.conbuildmat.2014.01.020.
Sayadi, A. A., Rahman, A. B. A., Sayadi, A., Bahmani, M., and Shahryari, L. (2015). “Effective of elastic and inelastic zone on behavior of glass fiber reinforced polymer splice sleeve.” Construction and Building Materials, Vol. 80, pp. 38–47, DOI: 10.1016/j.conbuildmat.2015.01.064.
Seo, S. Y., Nam, B. R., and Kim, S. K. (2016). “Tensile strength of the grout-filled head-splice-sleeve.” Construction and Building Materials, Vol. 124, pp. 155–166, DOI: 10.1016/j.conbuildmat.2016.07.028.
Untrauer, R. E. and Henry, R. L. (1965). “Influence of normal pressure on bond strength.” ACI Journal Proceedings, Vol. 62, No. 5, pp. 577–586, DOI: 10.14359/7711.
Yee, A. A. (1968). Splice sleeve for reinforcing bars, US Pat. 3540, 763.
Yee, A. A. (2001). “Structural and economic benefits of precast/prestressed concrete construction.” PCI Journal, Vol. 46, No. 4, pp. 34–43, DOI: 10.15554/pcij.07012001.34.42.
Zheng, Y. F. and Guo, Z. X. (2016). “Experimental study and finite element analysis on the behavior of deformed gout-filled pipe splice.” Journal of Building Structures, Vol. 37, No. 3, pp. 94–102, DOI: 10.14006/j.jzjgxb.2016.03.012.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zheng, Y., Guo, Z. & Zhang, X. Effect of Grout Properties on Bond Behavior of Grouted Pipe Splice. KSCE J Civ Eng 22, 2951–2960 (2018). https://doi.org/10.1007/s12205-017-0034-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-017-0034-y