Abstract
Intro
Force measurements of the nucleus, the strongest organelle, have propelled the field of mechanobiology to understand the basic mechanical components of the nucleus and how these components properly support nuclear morphology and function. Micromanipulation force measurement provides separation of the relative roles of nuclear mechanical components chromatin and lamin A.
Methods
To provide access to this technique, we have developed a universal micromanipulation apparatus for inverted microscopes. We outline how to engineer and utilize this apparatus through dual micromanipulators, fashion and calibrate micropipettes, and flow systems to isolate a nucleus and provide force vs. extensions measurements. This force measurement approach provides the unique ability to measure the separate contributions of chromatin at short extensions and lamin A strain stiffening at long extensions. We then investigated the apparatus’ controllable and programmable micromanipulators through compression, isolation, and extension in conjunction with fluorescence to develop new assays for nuclear mechanobiology.
Results
Using this methodology, we provide the first rebuilding of the micromanipulation setup outside of its lab of origin and recapitulate many key findings including spring constant of the nucleus and strain stiffening across many cell types. Furthermore, we have developed new micromanipulation-based techniques to compress nuclei inducing nuclear deformation and/or rupture, track nuclear shape post-isolation, and fluorescence imaging during micromanipulation force measurements.
Conclusion
We provide the workflow to build and use a micromanipulation apparatus with any inverted microscope to perform nucleus isolation, force measurements, and various other biophysical techniques.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
The nucleus is the stiffest organelle which acts to organize and compartmentalize the genome and its major functions. Recent experiments reveal that loss of nuclear rigidity results in abnormal nuclear shape and rupture which cause dysfunction.17,30 These findings clearly link nuclear mechanics back to human diseases, many of which present abnormal nuclear morphology as a diagnostic and prognostic hallmark.33
A powerful tool for studies of structure and mechanics of subcellular structures is micromanipulation using glass micropipettes and microneedles, which have been employed to study chromosomes, molecular motors, and other subcellular components.2,5,15,18,21,22,23,27,35 Our own work using this approach to study cell nuclei has provided the novel separation of the two major mechanical elements, chromatin and lamins, commonly disrupted in diseases that present abnormal nuclear shape. Micromanipulation provides isolation of nuclei from living cells and force measurements that reveal a short extension regime, which interrogates chromatin-based nuclear mechanics, while the long extension regime reveals strain stiffening controlled by lamin A.31
Physical simulations matched to micromanipulation experiments show that geometry of the nucleus, chromatin, and lamins underlies this phenomena of a short-extension and stronger long-extension regimes.3,14 This technique has provided a significant step forward in nuclear mechanics and mechanobiology studies including how histone modification state modulates nuclear mechanics, morphology, and function,28,29 how HP1α functions as a chromatin crosslinker in the nucleus and in mitotic chromosomes,34 and how the genome is highly crosslinked.4 These novel chromatin discoveries are also of interest to chromatin biology.1 However, until now, this technique has been inaccessible to other scientists. Here we provide the methodology to build a micromanipulation setup onto any inverted microscope, isolate nuclei, perform force measurements, and outline various other novel biophysical techniques.
Micromanipulator Setup
The programmable micromanipulators (MP-285, Sutter Instrument, Table 1) with modulable step size were mounted on rigid stands that attach to the air table of any inverted microscope (Fig. 1). A common air table (TMC CleanBench, 30 × 30 or 60 × 36 inches) is required to dampen any vibrations that could be transferred to the micropipette, and thus provides stability. The rigid stands were positioned with a dovetail platform positioned about 1 inch above the microscope stage, 25 mm. The inner corner of the dovetail platform should be roughly 6 inches (150 mm) horizontal and 4 inches (100 mm) backwards from the objective’s field of view. Micromanipulators were mounted to the rigid stand so that they face inwards, and the motor is outwards. To make up this distance to the objective, the micropipette holder was attached to the end of a z vertical and z horizontal extender and set at an angle of 30° (Supplemental protocols). Micropipette holders (Narishige) were loaded with a cut micropipette and placed in the micromanipulator holder for fine-tuned adjustments.
Optional: An optional helper/third micromanipulator, not necessary to be programmable, can be added to provide micromanipulation support to hold items or to provide a biochemical spray. To decrease bulk and fit around other components, we suggest it be added at a 45 angle on a rigid stand and the use of multiple 2× horizontal extenders to make up distance to the objective field of view.
Pipette Pulling
A pipette puller (P-97, Sutter Instrument, Table 1) is used to taper capillaries into micropipettes for use in micromanipulation experiments. A glass capillary is loaded into the puller evenly and clamped. Different glass capillaries and their respective program parameters are used depending on the type of micropipette being fashioned. Spray or Pull micropipettes are stiffer and used a 6 in, OD 1.0 mm, No Filament (TW100-6) micropipette with a pull program of Heat 564, Pull 110, Velocity 110, Time 100, and Pressure 500 (for cooling, 1 unit = 1/2 ms). Force micropipettes are more flexible and were fabricated from 6 in, OD 1.0 mm, Filament (TW100F-6) micropipettes with a pull program Heat 561, Pull 220, Velocity 200, Time 20, Pressure 500. Each pull takes roughly 10 s and completes with separation of the capillary into two separate micropipettes (Supplemental protocols and Supplemental movie 1).
Pipette Cutting
Pipette pullers provide coarse grain size and shape, and further fine cutting is required to shape micropipettes into having a defined opening size. We modified the approach for cutting micropipettes using the MF-200 WPI microforge by constructing a custom micropipette holder/positioner using Thorlabs parts and an alligator clip (Table 1 and Supplemental protocols; original design by M.G. Poirier). This custom micropipette holder allows for coarse positioning in x and y using a base plate that slides easily on bench surfaces. The Thorlabs micropositioner allows for fine adjustment in x, y, z directions to position the micropipette tip in the field of view of the microscope where the cutting filament will be brought to cut. When assembling the cutting apparatus, we loaded the cutting filament in a stage holder to couple the cutting to stage z movement but decoupled from the microscope objective focal plane. This allows moving the cutting filament out of focus so that the micropipette can be positioned without collision. When ready to cut, the cutting filament is turned on to a desired heat (determined empirically) and passed through the micropipette using the stage movement to cut the micropipette (Supplemental movie 2). Micropipettes were cut at defined outer diameter sizes of 4–5 µm for pull and force, 6 µm for spray, and 4–10 µm for compression micropipettes (see Fig. 4).
Pipette Filling
Micropipettes small size taper and opening requires front filling and back filling of biochemicals. Front filling was accomplished by loading the micropipette in a holder attached manual micromanipulator (KITE-L/R, World Precision Instruments) and to tubing connected to a vacuum source (WOB-L® 2511, Welch) to pull liquid through the tip via suction (Table 1). A minute of suction is sufficient to front load the micropipette with liquid. After, a generic 10 mL syringe with Luer tips connected to a long MicroFil tip (WPI, MF28G-5) is used to back fill the micropipette fully. The needle should be placed all the way into the micropipette before back filling to minimize bubbles forming (Supplemental movie 3). This is followed by pointing the micropipette tip down and necessary gentle flicking on the body of the micropipette to remove any visibly trapped air bubbles that would disrupt flow in this system (Supplemental protocols).
Pipette Loading and Finding
Cut and filled micropipettes were then loaded into a micropipette holder system that provides stability and a controllable flow source (Supplemental movie 4). The IM-H1 Narishige holder system provides attachment to BR-AW micromanipulation clips, a stable holder, and small tubing that can easily be connected to an open syringe to create a gravity well system to control aspiration and spraying through the micropipette (Table 1 and Supplemental protocols). Use of a rubber bulb at the top of the syringe can facilitate flow modulation through this system. However, the micropipette must be first located in the microscopes field of view (FOV) using the micromanipulator controller. Visually the micropipette is aligned with FOV, then lowered into the low profiled cell culture well, located on 10× for centering, and then finally located in the FOV of the 60X object just above the cells and cover glass (Supplemental movie 5).
Force Calibration
A primary calibration micropipette with a known spring constant is required for the methodology used in creating all other calibrated micropipettes for force measurement. We used a microforce sensor (FT-S100, FemtoTools, Table 1) that converts force to voltage in a standardized manner to calibrate a primary calibration micropipette. We programmed movement of the primary calibrated force micropipette to move 10 and 50 µm while in contact with the microforce sensor. This process was repeated in triplicate recording the voltage at maximum compression. The purpose of the sensor is to translate the force of the calibration micropipette into a voltage; the voltage can then be converted back into a force given the volt per force of the sensor. By pressing the calibration micropipette into the sensor at specific and repeatable amounts, the spring constant of the calibration micropipette can be derived as force (given by the sensor) divided by distance (given by the preprogrammed distance for the micropipette to move). A custom program was written in Labview for calculations (available upon request). For nuclear mechanics we suggest a primary calibration micropipette of 1.5–2 nN/µm.
Force micropipettes are cut to a defined size of 4–5 µm and spring constant of 1.2–2 nN/µm. We load a primary calibration micropipette with known spring constant force micropipette (determined above) and a newly cut force micropipette with an unknown spring constant. The unknown force micropipette is held stationary while the known is brought into contact with a set overlap length of 15 µm. This is the initial position. Next the known micropipette is programmed to move 6 µm along the x-axis to push against the unknown micropipette via the micromanipulator at 400 nm/s and then hold. This position is the resistance position. Finally, the unknown force micropipette is moved in the y-axis away quickly to withdraw it. The known micropipette then jumps to its unresisted position now that it is not held back by the other unknown micorpipette. If both micropipettes are of equal strength, then after the known micropipette is told to move 6 µm, both micropipettes will be deflecting the same amount 3 µm. If the resistance position is less than the unknown micropipette is stronger, if greater then unknown is weaker (resistance—initial) divided by (final—resistance) multiplied by known spring constant.
Nuclear Isolation and Force Measurements
Micromanipulation can isolate nuclei from living cells in a few minutes. Our most used cell line is vimentin null (MEF V−/−) which provides easy isolation without the need for actin depolymerization and provides similar cell biological and mechanical measurements28,31 (Fig. 2a). Most other cell types can be treated with 1 µg/mL latrunculin A for 45 min before isolation to depolymerize actin to allow for nucleus isolation (Fig. 2b). A micropipette sized to 4–5 µm tip is loaded with mild detergent (triton X-100 0.05%) for nucleus isolation. This micropipette is located in 10× objective before moving to 60× oil objective for finer control of the micropipette relative to the nucleus. The gravity well is lifted to expel the mild detergent and break open the plasma membrane (Supplemental protocols). A second micropipette of similar size is loaded with PBS for capture of the isolated nucleus. This micropipette aids isolation by pulling the nucleus out of cell remnants and serving as the future pull micropipette. The spray micropipette is removed and replaced with a precalibrated force micropipette in preparation for force measurements.
Use of dual micromanipulation allows for controlled extension of a single isolated nucleus. Isolation and attachment to one micropipette (aka pull micropipette) is followed by adding a second force calibrated micropipette (aka force micropipette) attaching to the opposite side of the nucleus. Attachment is accomplished by dropping the gravity well to provide aspiration of the nucleus into the micropipette which causes non-specific attachment of the nucleus to the glass of the micropipette after which the gravity well is moved back to neutral. The force micropipette is tracked while the pull micropipette is moved into position so that each micropipette is parallel, and the nucleus is set for extension. After moving into position, the pull micropipette is moved to relieve any pulling or pushing.
We tested whether this new system performs similarly to the original system. Single nuclei were subjected to controlled micromanipulation extension at 50 nm/s by moving the pull pipette and tracking the position of both the force and pull micropipettes. The deflection of the force micropipette multiplied by precalibrated spring constant provides a measure of force (F = Δx * kfp) while the change in distance between micropipettes tracks nucleus extension (Δx = pull − force pipette position; Fig. 3a). The slope of force/extension (nN/µm) line provides the spring constant of the nucleus (example force measurement calculation in Supplemental protocols). The new setup force vs. extension graphs recapitulate the two-regime force response with an initial spring constant measured by slope at < 3 µm (blue, ~ 30% strain) which switches to a stiffer regime at extensions > 3 µm (red; Fig. 3a and 3b). The new apparatus provided similar average force measurements of MEF V−/− for short (chromatin) and long (chromatin + lamin A) regimes compared to the original apparatus31 (Fig. 3c). The micromanipulation apparatus has provided the ability to measure nuclei in many different cell types providing comparison of relative strengths (Fig. 3d, Supplemental Table 1). Overall, all nuclei with high ratios of lamin A to lamin B produce a strain stiffening at long extensions, except HEK293 which have low levels of lamin A (Fig. 3e;31), in agreement with previous reports.36
Nuclear Compression via Micromanipulation
Fine control of micropipettes provides the ability to assay nuclear resistance to moving compression. Force calibrated stiffer micropipettes (5 nN/µm) sized 4–10 µm tip were used to either compress the nucleus or compress with horizontal motion to the edge of the nucleus while imaging nuclear compartmentalization via nuclear localization signal green fluorescence protein (NLS-GFP, Figs. 4a–4c). Our novel data reveals that simple local compression of nuclei does not compromise the nuclear envelope, while local moving compression resulted in substantial increase in nuclear ruptures from blebbed or normally shaped nuclei (Figs. 4a, 4b). Furthermore, generating compression with micropipettes can temporarily induce small blebs, though they reabsorb rapidly (Fig. 4c). This ability to modulate local compression with or without motion could be leveraged to investigate nuclear ruptures as well as nuclear bleb formation.
Micromanipulation-Based Single Nucleus Isolation is Adaptable to Many Approaches
Nucleus isolation can provide a fresh, gently isolated nucleus for many single nucleus/cell studies. The nucleus can be held with one micropipette while the second or optional third micropipette could be loaded with any biochemical to spray onto the nucleus for biochemical assays. Furthermore, isolation of a single nucleus can be used to probe nucleus elastic or plastic properties outside of the cell through measuring nucleus size and shape. For example, here we show novel data that nuclear blebs are persistent/plastic deformations that remain upon nucleus isolation from the cell (Fig. 4d), which agrees with previous work showing cutting of the cell did not relieve abnormal nuclear shape.38 This technique can be adapted to any number of new approaches requiring a freshly and gently isolated nucleus.
Visualizing Nuclear Organization During Micromanipulation Force Measurements
The ability to build the micromanipulation apparatus onto any microscope allows for greater exploration of imaging alongside force extension measurements. Previously, micromanipulation experiments on mitotic chromosomes have benefited greatly from coupling to imaging approaches to see the finer detailed organization of chromosomes.5,35 This apparatus was built onto a basic widefield imaging system. We provide proof-of-principal imaging for H2B-RFP (Invitrogen, CellLight) during micromanipulation force measurements (Fig. 4e). There are many possible approaches for imaging of bulk chromatin, chromosome territories, and specific loci in conjunction with micromanipulation.
Conclusion
Micromanipulation force measurements have provided a novel leap forward in nuclear mechanics studies. Each force measurement technique has found its niche in mechanobiology. Optical tweezers in yeast, that do not have lamins, provide probing of chromatin-peripheral tethering and chromatin26,41 while in mammalian cells probe small local deformations.11 Micropipette aspiration provides a strong measure of lamin-based nuclear mechanics through high local strain > 100%6,12,20,36,40 which has provided much of what we know about lamins. Atomic force microscopy provides general changes in nuclear strength through perturbations of either chromatin9,10,19 or lamins.25,39 However, none of these techniques could separate chromatin and lamin mechanical contributions. Micromanipulation provides controlled deformation where both force and extension could be measured simultaneously that was necessary to separate chromatin and lamin regimes.3,31 Recently, the ability to finely track nuclear deformation and force via combined atomic force microscopy and light sheet imaging has recapitulated the separation of chromatin-dominated short deformation regime and lamin A/C-based stiffening at higher deformation.13 These direct measures of the separate chromatin and lamin regimes agree with data provided indirectly by many other force measurement techniques and cell biology approaches.32 We have provided the ability to build and use a micromanipulation force measurement apparatus on any inverted microscope so that more researchers can access the ability to directly measure the separate contributions of chromatin and lamin A in their systems and experiments.
Micromanipulation apparatus provides novel approaches to expand the field of mechanobiology beyond nuclear force-extension measurements. Use of nuclear confinement approaches has led to recent discoveries in nuclear deformations, blebbing, and ruptures that cause nuclear dysfunction.8,16,24 Micropipette aspiration has been used to induce nuclear rupture loss to show rupture causes dysfunction16 and to connect amount of pressure applied to loss amount and rates.42 Here we outline nuclear compression with micropipettes providing the ability to induce long and short-lived blebs and induce nuclear ruptures to aid furth investigation of nuclear rupture dynamics, forces, and consequences to nuclear function. These approaches will be needed to keep pace with screens revealing more determinants of nuclear shape.37 Finally, combining nuclear fluorescence imaging during micromanipulation could provide a means to calibrate future force probes, as some lamin and lamin-chromatin force probes are already developed.7 Micromanipulation-calibrated fluorescence FRET force probes would not only allow researchers to measure force changes via fluoresce change in live cells in cell culture or in vivo systems but also separate chromatin and lamin A force regimes.
Abbreviations
- MEF:
-
Mouse embryonic fibroblast
- V -/-:
-
Vimentin null
- NLS-GFP:
-
Nuclear localization signal green fluorescence protein
References
Agbleke, A. A., et al. Advances in chromatin and chromosome research: perspectives from multiple fields. Mol. Cell. 79:881–901, 2020.
Almagro, S., D. Riveline, T. Hirano, B. Houchmandzadeh, and S. Dimitrov. The mitotic chromosome is an assembly of rigid elastic axes organized by structural maintenance of chromosomes (SMC) proteins and surrounded by a soft chromatin envelope. J. Biol. Chem. 279:5118–5126, 2004.
Banigan, E. J., A. D. Stephens, and J. F. Marko. Mechanics and buckling of biopolymeric shells and cell nuclei. Biophys. J. 113:1654–1663, 2017.
Belaghzal, H., et al. Liquid chromatin Hi-C characterizes compartment-dependent chromatin interaction dynamics. Nat. Genet. 53:367–378, 2021.
Biggs, R., P. Z. Liu, A. D. Stephens, and J. F. Marko. Effects of altering histone posttranslational modifications on mitotic chromosome structure and mechanics. Mol. Biol. Cell. 30:820–827, 2019.
Dahl, K. N., S. M. Kahn, K. L. Wilson, and D. E. Discher. The nuclear envelope lamina network has elasticity and a compressibility limit suggestive of a molecular shock absorber. J. Cell Sci. 117:4779–4786, 2004.
Danielsson, B.E. et al. Nuclear lamina strain states revealed by intermolecular force biosensor. bioRxiv. 2022. Available from: https://doi.org/10.1101/2022.03.07.483300.
Denais, C. M., et al. Nuclear envelope rupture and repair during cancer cell migration. Science. 352:353–358, 2016.
Dos Santos, Á., et al. DNA damage alters nuclear mechanics through chromatin reorganization. Nucleic Acids Res. 49:340–353, 2021.
Furusawa, T., et al. Chromatin decompaction by the nucleosomal binding protein HMGN5 impairs nuclear sturdiness. Nat. Commun. 6:6138, 2015.
Guilluy, C., et al. Isolated nuclei adapt to force and reveal a mechanotransduction pathway in the nucleus. Nat. Cell Biol. 16:376–381, 2014.
Ho, C. Y., D. E. Jaalouk, M. K. Vartiainen, and J. Lammerding. Lamin A/C and emerin regulate MKL1-SRF activity by modulating actin dynamics. Nature. 497:507–511, 2013.
Hobson, C. M., M. Kern, E. T. O’Brien 3rd., A. D. Stephens, M. R. Falvo, and R. Superfine. Correlating nuclear morphology and external force with combined atomic force microscopy and light sheet imaging separates roles of chromatin and lamin A/C in nuclear mechanics. Mol. Biol. Cell. 31:1788–1801, 2020.
Hobson, C. M., and A. D. Stephens. Modeling of cell nuclear mechanics: classes, components, and applications. Cells. 9:1623, 2020.
Houchmandzadeh, B., and S. Dimitrov. Elasticity measurements show the existence of thin rigid cores inside mitotic chromosomes. J. Cell Biol. 145:215–223, 1999.
Irianto, J., et al. Nuclear constriction segregates mobile nuclear proteins away from chromatin. Mol. Biol. 27:4011–4020, 2016.
Kalukula, Y., A. D. Stephens, J. Lammerding, and S. Gabriele. Mechanics and functional consequences of nuclear deformations. Nat. Rev. Mol. Cell Biol. 2022. https://doi.org/10.1038/s41580-022-00480-z.
Kawamura, R., et al. Mitotic chromosomes are constrained by topoisomerase II-sensitive DNA entanglements. J. Cell Biol. 188:653–663, 2010.
Krause, M., J. Te Riet, and K. Wolf. Probing the compressibility of tumor cell nuclei by combined atomic force-confocal microscopy. Phys. Biol. 10:065002, 2013.
Lammerding, J., et al. Lamins A and C but not lamin B1 regulate nuclear mechanics. J. Biol. Chem. 281:25768–25780, 2006.
Neelam, S., et al. Direct force probe reveals the mechanics of nuclear homeostasis in the mammalian cell. Proc. Natl. Acad. Sci. USA. 112:5720–5725, 2015.
Nicklas, R. B. Measurements of the force produced by the mitotic spindle in anaphase. J. Cell Biol. 97:542–548, 1983.
Poirier, M., S. Eroglu, D. Chatenay, and J. F. Marko. Reversible and irreversible unfolding of mitotic newt chromosomes by applied force. Mol. Biol. 11:269–276, 2000.
Raab, M., et al. ESCRT III repairs nuclear envelope ruptures during cell migration to limit DNA damage and cell death. Science. 352:359–362, 2016.
Schäpe, J., S. Prausse, M. Radmacher, and R. Stick. Influence of lamin A on the mechanical properties of amphibian oocyte nuclei measured by atomic force microscopy. Biophys. J. 96:4319–4325, 2009.
Schreiner, S. M., P. K. Koo, Y. Zhao, S. G. J. Mochrie, and M. C. King. The tethering of chromatin to the nuclear envelope supports nuclear mechanics. Nat. Commun. 6:7159, 2015.
Shimamoto, Y., S. Tamura, H. Masumoto, and K. Maeshima. Nucleosome-nucleosome interactions via histone tails and linker DNA regulate nuclear rigidity. Mol. Biol. Cell. 28:1580–1589, 2017.
Stephens, A. D., et al. Chromatin histone modifications and rigidity affect nuclear morphology independent of lamins. Mol. Biol. Cell. 29:220–233, 2018.
Stephens, A. D., et al. Physicochemical mechanotransduction alters nuclear shape and mechanics via heterochromatin formation. Mol. Biol. Cell. 30:2320–2330, 2019.
Stephens, A. D. Chromatin rigidity provides mechanical and genome protection. Mutat. Res.821:111712, 2020.
Stephens, A. D., E. J. Banigan, S. A. Adam, R. D. Goldman, and J. F. Marko. Chromatin and lamin A determine two different mechanical response regimes of the cell nucleus. Mol. Biol. Cell. 28:1984–1996, 2017.
Stephens, A. D., E. J. Banigan, and J. F. Marko. Separate roles for chromatin and lamins in nuclear mechanics. Nucleus. 9:119–124, 2018.
Stephens, A. D., E. J. Banigan, and J. F. Marko. Chromatin’s physical properties shape the nucleus and its functions. Curr. Opin. Cell Biol. 58:76–84, 2019.
Strom, A. R., et al. HP1α is a chromatin crosslinker that controls nuclear and mitotic chromosome mechanics. Elife. 2021. https://doi.org/10.7554/eLife.63972.
Sun, M., R. Biggs, J. Hornick, and J. F. Marko. Condensin controls mitotic chromosome stiffness and stability without forming a structurally contiguous scaffold. Chromosome Res. 26:277–295, 2018.
Swift, J., et al. Nuclear lamin-A scales with tissue stiffness and enhances matrix-directed differentiation. Science. 341:1240104, 2013.
Tamashunas, A. C., et al. High-throughput gene screen reveals modulators of nuclear shape. Mol. Biol. Cell. 31:1392–1402, 2020.
Tocco, V. J., et al. The nucleus is irreversibly shaped by motion of cell boundaries in cancer and non-cancer cells. J. Cell. Physiol. 233:1446–1454, 2018.
Vahabikashi, A., et al. Nuclear lamin isoforms differentially contribute to LINC complex-dependent nucleocytoskeletal coupling and whole-cell mechanics. Proc. Natl. Acad. Sci. USA. 119:e2121816119, 2022.
Vaziri, A., and M. R. K. Mofrad. Mechanics and deformation of the nucleus in micropipette aspiration experiment. J. Biomech.. 40:2053–2062, 2007.
Williams, J.F. et al. Phase separation enables heterochromatin domains to do mechanical work. bioRxiv. bioRxiv, 2020. https://doi.org/10.1101/2020.07.02.184127.
Zhang, Q., et al. Local, transient tensile stress on the nuclear membrane causes membrane rupture. Mol. Biol. 30:899–906, 2019.
Acknowledgments
We thank many labs for sharing of cells as resources including James Holaska lab (Rowan University) for the MDA-MB-231 cells; Bob Goldman lab (Northwestern University, Feinberg School of Medicine) MEF, HeLa, HEK293, BJ5ta cells; Vadim Backman lab (Northwestern University) for HT29 cells; Job Dekker (UMass Medical School) for U2OS and K562 cells. We also thank Katie Huang and Anish Shah for discussions and continued support with micromanipulation. MLC and ADS are supported by the Pathway to Independence Award R00GM123195 and via subcontract to Grant UM1HG011536. VK, RB, and JM are supported by the NIH through R01-GM105847 and via subcontracts to Grants UM1HG011536 and R01-GM135549.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Marilena L Currey, Viswajit Kandula, Ronald Biggs, John F. Marko, and Andrew D Stephens declare that they have no conflict of interest.
Citation diversity statement
Recent work in several fields of science has identified a bias in citation practices such that papers from women and other minority scholars are under-cited relative to the number of papers in the field. We recognize this bias and have worked diligently to ensure that we are referencing appropriate papers with fair gender and racial author inclusion.
Additional information
Associate Editor Michael R. King oversaw the review of this article.
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Supplementary file2 (MOV 20342 kb)
Supplementary file3 (MP4 203901 kb)
Supplementary file4 (MP4 189522 kb)
Supplementary file5 (MP4 79263 kb)
Supplementary file6 (MP4 27172 kb)
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Currey, M.L., Kandula, V., Biggs, R. et al. A Versatile Micromanipulation Apparatus for Biophysical Assays of the Cell Nucleus. Cel. Mol. Bioeng. 15, 303–312 (2022). https://doi.org/10.1007/s12195-022-00734-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12195-022-00734-y