Abstract
Since our initial development of the 256-detector row CT scanner (256-row CT) for four-dimensional (4D) imaging of moving organs in 2003, the results of physical performance and those in animal and human studies have suggested that this scanner may be useful in the examination of moving organs such as the heart and lungs. We have now developed a second model of the 256-row CT with improved specifications, with a scan time of 0.5 s/rotation at the highest speed and real-time reconstruction and display of dynamic 3D images (4D images). Here, we investigated the image characteristics of the new model, including spatial resolution, noise, and low-contrast detectability, as well as the dose profile and its integral in stationary phantoms. One volunteer and one patient with lung cancer were scanned, and their images were evaluated. The results show that all characteristics have been improved compared with those of the first model, with a remarkable improvement in the low-contrast detectability and slice sensitivity profile. In a contrast study, coronary arteries were clearly visualized in the normal heart without electrocardiographic gating. Movement and deformation of the tumor in the patient with lung cancer was captured in a study of a single breath cycle. The second model 256-row CT with improved characteristics may be beneficial in imaging of moving organs such as the heart and lungs, and may enable cerebral perfusion studies of the whole brain.
Similar content being viewed by others
References
Schardt P, Deuringer J, Freudenberger J, Hell E, Knupfer W, Mattern D, et al. New X-ray tube performance in computed tomography by introducing the rotating envelope tube technology. Med Phys. 2004;31:2699–706.
Endo M, Mori S, Tsunoo T, Kandatsu S, Tanada S, Aradate H, et al. Development and performance evaluation of the first model of 4-D CT scanner. IEEE Trans Nucl Sci. 2003;50:1667–71.
Mori S, Endo M, Tsunoo T, Kandatsu S, Tanada S, Aradate H, et al. Physical performance evaluation of a 256-slice CT scanner for 4-dimensional imaging. Med Phys. 2004;31:1348–56.
Mori S, Endo M, Obata T, Murase K, Fujiwara H, Kandatsu S, et al. Clinical potentials of the prototype 256-detector row CT scanner. Acad Radiol. 2005;12:148–54.
Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am. 1984;A1:612–9.
Mori S, Endo M, Nishizawa K, Tsunoo T, Aoyama T, Fujiwara H, et al. Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry. Med Phys. 2005;32:1061–9.
Kondo C, Mori S, Endo M, Kusakabe K, Suzuki N, Hattori A, et al. Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography. J Comput Assist Tomogr. 2005;29:694–8.
Sato Y, Kanmatsuse K, Inoue F, Horie T, Kato M, Kusama J, et al. Noninvasive coronary artery imaging by multislice spiral computed tomography: a novel approach for a retrospective ECG-gated reconstruction technique. Circ J. 2003;67:107–11.
Inoue F, Sato Y, Matsumoto N, Tani S, Uchiyama T. Evaluation of plaque texture by means of multislice computed tomography in patients with acute coronary syndrome and stable angina. Circ J. 2004;68:840–4.
Mori S, Endo M, Kondo C, Tanada S. Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging. Acad Radiol. 2006;13:701–12.
Miles KA, Griffiths MR. Perfusion CT; a worthwhile enhancement? Brit J Radiol. 2003;76:220–31.
Mori S, Obata T, Nakajima N, Ichihara N, Endo M. Volumetric perfusion CT using 256-detector row CT scanner: preliminary study with healthy porcine model. Am J Neuroradiol. 2006;26:2536–41.
Keall PJ, Joshi S, Vedam SS, Siebers JV, Kini VR, Mohan R. Four-dimensional radiotherapy planning for DMCL-based respiratory motion tracking. Med Phys. 2005;32:942–51.
Mori S, Baba M, Yashiro T, Komatsu S, Kandatsu S, Endo M. Volumetric cine imaging for four-dimensional radiation therapy planning using the second model of the 256-detector row CT-scanner: initial experience in lung cancer. Eur J Radiol Extra. 2006;57:71–3.
Acknowledgments
We wish to express our appreciation to Naoki Sugihara, Yasuo Saito, Akira Adachi and Hiroaki Miyazaki of Toshiba Medical Systems Corporation, Japan for their support. This work was supported by the 4D-CT Research Group at the National Institute of Radiological Sciences, Japan.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Endo, M., Mori, S., Kandatsu, S. et al. Development and performance evaluation of the second model 256-detector row CT. Radiol Phys Technol 1, 20–26 (2008). https://doi.org/10.1007/s12194-007-0004-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12194-007-0004-z