Skip to main content
Log in

An electrostatic sensor for the continuous monitoring of particulate air pollution

  • Environmental Engineering
  • Published:
Korean Journal of Chemical Engineering Aims and scope Submit manuscript

Abstract

We developed and evaluated a particulate air pollution sensor for continuous monitoring of size resolved particle number, based on unipolar corona charging and electrostatic detection of charged aerosol particles. The sensor was evaluated experimentally using combustion aerosol with particle sizes in the range between approximately 50 nm and several microns, and particle number concentrations larger than 1010 particles/m3. Test results were very promising. It was demonstrated that the sensor can be used in detecting particle number concentrations in the range of about 2.02×1011 and 1.03×1012 particles/m3 with a response of approximately 100 ms. Good agreement was found between the developed sensor and a commercially available laser particle counter in measuring ambient PM along a roadside with heavy traffic for about 2 h. The developed sensor proved particularly useful for measuring and detecting particulate air pollution, for number concentration of particles in the range of 108 to 1012 particles/m3.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. EPA, National Ambient Air Quality Standards for Particulate Matter, Final Rule, Federal Register, 62, 38651(1997).

    Google Scholar 

  2. W. C. Hinds, Aerosol technology, John Wiley & Sons, New York, USA (1999).

    Google Scholar 

  3. P. Intra and N. Tippayawong, Maejo Int. J. Sci. Technol., 1, 120 (2007).

    CAS  Google Scholar 

  4. T. Johnson, S. Kaufman and A. Medved, 6 th Int. ETH Conference Nanoparticle Measurement, Zurich, Switzerland, 19–21 August (2002).

    Google Scholar 

  5. J. Wei, Development of a method for measuring surface area concentration of ultrafine particles, D. Eng. Thesis, University of Duisburg-Essen, Germany (2007).

    Google Scholar 

  6. P. Intra and N. Tippayawong, J. Japan Soc. Appl. Electromagnet. Mech., 17, s17 (2009).

    Google Scholar 

  7. J. K. Kim and S. C. Kim, Korean J. Chem. Eng., 18, 531 (2001).

    Article  CAS  Google Scholar 

  8. M. Murtomaa, P. Pekkala, T. Kalliohaka and J. Paasi, J. Electrostat., 63, 571 (2005).

    Article  CAS  Google Scholar 

  9. F. O. J-Fatokun, L. Morawska, M. Jamriska and E. R. Jayaratne, Atmos. Environ., 42, 8827 (2008).

    Article  CAS  Google Scholar 

  10. L. Li, D. R. Chen and P. J. Tsai, J. Electrostat., 67, 765 (2009).

    Article  CAS  Google Scholar 

  11. L. Li, D. R. Chen and P. J. Tsai, J. Nanopart. Res., 11, 111 (2009).

    Article  Google Scholar 

  12. L. Ntziachristos, B. Giechaskiel, J. Ristimaki and J. Keskinen, J. Aerosol Sci., 35(8), 943 (2004).

    Article  CAS  Google Scholar 

  13. A. Rostedt, M. Marjamaki, J. Yli-Ojanpera, J. Keskinen, K. Janka, V. Nienela and A. Ukkonen, Aerosol Air Qual. Res., 9, 470 (2009).

    Google Scholar 

  14. T. Lanki, J. Tikkanen, K. Janka, P. Taimisto and M. Lehtimaki, J. Physics Conf. Series, 304, 012013 (2011).

    Article  Google Scholar 

  15. TSI Incorporated, Instruction Manual for Electrical Aerosol Detector Model 3070A, Minnesota, USA (2002).

    Google Scholar 

  16. J. K. Agrawal and G. J. Sem, J. Aerosol Sci., 11, 343 (1980).

    Article  Google Scholar 

  17. TSI Incorporated, Instruction Manual for Condensation Particle Counter Model 3010, Minnesota, USA (2002).

    Google Scholar 

  18. V. A. Marple and K. Willeke, Atmos. Environ., 10, 891 (1976).

    Article  Google Scholar 

  19. P. Intra, A. Yawootti, U. Vinitketkumnuen and N. Tippayawong, Korean J. Chem. Eng., 29, 1044 (2012).

    Article  CAS  Google Scholar 

  20. P. Intra and N. Tippayawong, Aerosol Air Qual. Res., 11, 187 (2011).

    Google Scholar 

  21. M. Kobashi, Particle agglomeration induced by alternating electric fields, Ph.D. Thesis, Stanford University (1979).

    Google Scholar 

  22. P. Intra, J. Electrostat., 70, 136 (2012).

    Article  Google Scholar 

  23. T.G. Cleary, G.W. Mulholland, L. K. Ives, R. A. Fletcher and J.W. Gentry, Aerosol Sci. Technol., 16, 166 (1992).

    Article  CAS  Google Scholar 

  24. P. Intra and N. Tippayawong, Korean J. Chem. Eng., 26, 1770 (2009).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Panich Intra.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Intra, P., Yawootti, A. & Tippayawong, N. An electrostatic sensor for the continuous monitoring of particulate air pollution. Korean J. Chem. Eng. 30, 2205–2212 (2013). https://doi.org/10.1007/s11814-013-0168-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11814-013-0168-7

Key words

Navigation