This paper reports experimental and computational fluid dynamics (CFD) modeling studies on the performance of three modified valves operating in a valve tray column. The original and modified valves including vnotched, warped and double-valve are tested experimentally. The experimental rig was a Perspex column having a single valve equipped with a fluctuating plate to measure the quality of gas distribution by using laser sensors. Two-stage nested designs were employed to show the repeatability and consistency of the measurements. In the CFD modeling, the volume of fluid (VOF) method was used to model the gas-liquid two-phase flow inside the column. A good agreement was observed between experimental data and the CFD predictions. The results showed that the double-valve layout provides a better gas distribution, smaller bubbles with greater interface area and lower pressure drop in comparison with the original and the two other modified valves.
Similar content being viewed by others
References
M. Ide, H. Uchiyama and T. Ishikura, Korean J. Chem. Eng., 16, 698 (1999).
N. Tunthikul, P. Wongsuchoto and P. Pavasant, Korean J. Chem. Eng., 23, 881 (2006).
J. L. Peytavy, M. H. Huor and R. Bugarel, Chem. Eng. Process., 27, 155 (1990).
A. Kozio and J. M. Kowiak, Chem. Eng. Process., 27, 145 (1990).
B. Chang, S. Lee, H. Kwon and I. Moon, Comput. Chem. Eng., 22, 863 (1998).
E. F. Wijn, Chem. Eng. J., 70, 143 (1998).
B. H. L. Betlem, J. E. Rijnsdorp and R. F. Azink, Chem. Eng. Sci., 53, 3991 (1998).
E. F. Wijn, Chem. Eng. J., 73, 191 (1999).
B. M. Jacimovic, Chem. Eng. Sci., 55, 3941 (2000).
D. P. Rao, C.V. Goutami and S. Jain, Comput. Chem. Eng., 25, 1141 (2001).
L. M. Naphtali and D. P. Sandholm, AIChE J., 17, 148 (1971).
Y. H. Kim, K. S. Hwang and M. Nakaiwa, Korean J. Chem. Eng., 21, 1098 (2004).
Z. Lei, Q. Li, C. Li and B. Chen, Korean J. Chem. Eng., 21, 1003 (2004).
K. T. Yu, X. G. Yan, X. Y. You and C. J. Liu, Chem. Eng. Res. Des., 77, 554 (1999).
J. M. Van Baten and R. Krishna, Chem. Eng. J., 77, 143 (2000).
D. L. Bennett, R. Agrawal and P. J. Cook, AIChE J., 29, 434 (1983).
J. M. Van Baten, J. Ellenberger and R. Krishna, Catal. Today, 66, 233 (2001).
G. Gesit, K. Nandakumar and K. T. Chuang, AIChE J., 49, 910 (2003).
Z. M. Sun, K. T. Yu, X. G. Yuan and C. J. Liu, Chem. Eng. Sci., 62, 1839 (2007).
D. Noriler, H. F. Meier, A. A. C. Barros and M. R. WolfMaciel, Chem. Eng. J., 136, 133 (2008).
S. Pradhan and A. Kannan, Korean J. Chem. Eng., 22, 441 (2005).
D. C. Montgomery, Design and analysis of experiments, John Wiley & Sons, New York (2001).
L. Davies, Efficiency in research, development and production: the statistical design and analysis of chemical experiments, Royal Society of Chemistry, Cambridge (1993).
C. W. Hirt and B. D. Nichols, J. Comput. Phys., 39, 201 (1981).
M. Lappa, J. Biomech., 38, 185 (2005).
Fluent Inc, Fluent 6.2 User’s Guide (2005).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Alizadehdakhel, A., Rahimi, M. & Alsairafi, A.A. Numerical and experimental investigation on a new modified valve in a valve tray column. Korean J. Chem. Eng. 26, 475–484 (2009). https://doi.org/10.1007/s11814-009-0081-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11814-009-0081-2