Skip to main content
Log in

Repetitive PD control strategy with inverse transfer function compensation for CVCF inverter

  • Published:
Journal of Control Theory and Applications Aims and scope Submit manuscript

Abstract

A novel repetitive control strategy for the output waveform of single-phase CVCF inverters is presented. In this scheme, the inverse transfer function of inverter is used as a compensator to obtain stable and satisfy harmonic rejection. Besides, PD controller is adopted to improve transient performance. Simulation and experimental results, which are gotten from a DSP-based 400Hz, 5.5KW inverter, indicate that the proposed control scheme can achieve not only low THD during steady-state operation but also fast transient response during load step change.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Y. Y. Tzou, High performance programmable AC power source with low harmonics distortion using DSP-Based repetitive control technique, IEEE Trans, on Power Electronics, Vol. 12, No. 4, pp. 715–725, 1997.

    Article  Google Scholar 

  2. P.D. Ziogas, Optimum voltage and harmonic control PWM techniques for three-phase inverters, IEEE Trans, on Industrial Application, Vol. 16, No. 4,pp. 542–546,1980.

    Google Scholar 

  3. P. D. Ziogas. Application of current source inverters in UPS systems, IEEE Trans. on Industrial Application, Vol. 25, No. 3, pp. 408–418,1989.

    Article  Google Scholar 

  4. H. Toshimasa, K. Atsuo, G. H. Richard, Waveform compensation of PWM inverter with cyclic fluctuating loads. IEEE Trans. on Industrial Application, Vol. 24, No. 4, pp. 582–589,1988.

    Article  Google Scholar 

  5. A. Kawamura, Instantaneous feedback controlled PWM inverter with adaptive hysteresis, IEEE Trans, on Industrial Application, Vol.20, No.5,pp. 769–775,1984.

    Google Scholar 

  6. K. Zhang, Y. Kang, J. Xiong, et al, Direct repetitive control of SPWM inverter for UPS purpose, IEEE Trans, on Power Electronics, Vol. 18, No.3,pp. 784–792,2003.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This work was supported by the National Natural Science Foundation of China (No. 50007004).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Duan, S., Liu, B., Kang, Y. et al. Repetitive PD control strategy with inverse transfer function compensation for CVCF inverter. J. Control Theory Appl. 2, 121–125 (2004). https://doi.org/10.1007/s11768-004-0055-1

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11768-004-0055-1

Keywords

Navigation