Skip to main content
Log in

AuNPs-/c-MWCNT-/GQDs-modified electrode-based genosensor for early diagnosis of rheumatic heart disease

  • Short Communication
  • Published:
Chemical Papers Aims and scope Submit manuscript

Abstract

In the present work, a specific DNA sensor has been fabricated by immobilizing 5’-NH2-labeled single-stranded DNA probe (ssG-DNA) specific to S. pyogenes on AuNPs-/c-MWCNT-/GQDs-based screen-printed electrode. Further, hybridization studies were performed using different concentrations of DNA isolated from bacteria and swab samples from susceptible patients. Electrode surface modifications were characterized using scanning electron microscopy (SEM). Electrochemical response in terms of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) was recorded and analyzed to validate DNA hybridization. The limit of detection (LOD) and the sensitivity of the developed sensor were found to be 0.2 pg/µL and 1095.2 µAcm− 2 ng−1, respectively. The sensor was found stable for 6 months with 9–10% loss in initial DPV current at 4 °C. The sensor is highly specific, simple, and sensitive with patient swab samples and takes only 20 min for detection of S. pyogenes infection.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Scheme 1
Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  • Bhardwaj H, Pandey MK, Sumana G (2019) Electrochemical Aflatoxin B1 immunosensor based on the use of graphene quantum dots and gold nanoparticles. Microchim Acta 186(8):1–12

    Article  CAS  Google Scholar 

  • Borek AL, Obszańska K, Hryniewicz W, Sitkiewicz I (2012) Detection of streptococcus pyogenes virulence factors by multiplex PCR. Virulence 3(6):529–533

    Article  Google Scholar 

  • Carapetis JR, Beaton A, Cunningham MW, Guilherme L, Karthikeyan G, Mayosi BM et al (2016) Acute rheumatic fever and rheumatic heart disease. Nat Rev Dis Primers 2(1):1–24

    Article  Google Scholar 

  • Guilherme L, Köhler KF, Kalil J (2011) Rheumatic heart disease: mediation by complex immune events. Adv Clin Chem 53(2):31–50

    Article  CAS  Google Scholar 

  • Kala D, Sharma TK, Gupta S, Nagraik R, Verma V, Thakur A, Kaushal A (2020) AuNPs/CNF-modified DNA biosensor for early and quick detection of O. tsutsugamushi in patients suffering from scrub typhus. 3 Biotech 10:446

    Article  Google Scholar 

  • Kala D, Sharma TK, Gupta S, Verma V, Thakur A, Kaushal A et al (2021) Graphene oxide nanoparticles modified paper electrode as a biosensing platform for detection of the htrA gene of O. tsutsugamushi. Sensors 21(13):4366

    Article  CAS  Google Scholar 

  • Kaushal A, Goyal L, Kumar A (2011) Recent advances in the diagnosis of rheumatic heart disease. Biosci Biotech Res Comm 4:1–9

    CAS  Google Scholar 

  • Kaushal A, Kumar D, Khare S, Kumar A (2012) SpeB gene as a specific genetic marker for early detection of rheumatic heart disease in human. Cell Mol Biol 22(1):50–54

    Google Scholar 

  • Kaushal A, Singh S, Kala D, Kumar D, Kumar A (2016) SpeB genosensor for rapid detection of Streptococcus pyogenes causing damage of heart valves in human. Cell Mol Biol 62:140

    Google Scholar 

  • Kaushal A, Singh S, Kumar A, Kumar D (2017) Nano-Au/cMWCNT modified speB gene specific amperometric sensor for rapidly detecting Streptococcus pyogenes causing rheumatic heart disease. Indian J Microbiol 57:121–124

    Article  CAS  Google Scholar 

  • Nagraik R, Sethi S, Sharma A, Kumar D, Kumar D, Kumar AP (2021) Ultrasensitive nanohybrid electrochemical sensor to detect LipL32 gene of Leptospira interrogans. Chem Pap 75:5453–5462

    Article  CAS  Google Scholar 

  • Singh S, Kaushal A, Khare S, Kumar P, Kumar A (2014) Gold–mercaptopropionic acid–polyethyleneimine composite based DNA sensor for early detection of rheumatic heart disease. Analyst 139(14):3600–3606

    Article  CAS  Google Scholar 

  • Stefanov C, Negut CC, Gugoasa LAD, van Staden JKF (2020) Gold nanoparticle-graphene quantum dots nanozyme for the wide range and sensitive electrochemical determination of quercetin in plasma droplets. Microchim Acta 187(11):1–10

    Article  Google Scholar 

  • Stevens DL, Stevens DL, Kaplan EL (eds) (2000) Streptococcal infections: clinical aspects, microbiology, and molecular pathogenesis. Oxford University Press, USA

    Google Scholar 

  • Tajbakhsh S, Gharibi S, Zandi K, Yaghobi R, Asayesh G (2011) Rapid detection of Streptococcus pyogenes in throat swab specimens by fluorescent in situ hybridization. Eur Rev Med Pharmacol Sci 15(3):313–317

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dinesh Kumar.

Ethics declarations

Conflict of interest

The authors declare no conflict of interest associated with this manuscript.

Ethical Approval

We state that this material has not been published and is not under active consideration by another journal.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kaushal, A., Kumar, A., Kala, D. et al. AuNPs-/c-MWCNT-/GQDs-modified electrode-based genosensor for early diagnosis of rheumatic heart disease. Chem. Pap. 76, 4621–4626 (2022). https://doi.org/10.1007/s11696-022-02163-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11696-022-02163-7

Keywords

Navigation