Abstract
India’s surface water and groundwater distribution is temporally variable due to the monsoon. Agriculture is one of the dominant economic sectors in India. Groundwater quality is regularly assessed to determine usability for drinking and irrigation. In this study, World Health Organization and Bureau of Indian Standards guidelines were used to determine suitability of groundwater near artificial recharge structures (ARS) with a focus on the structures´ impact on groundwater quality. Groundwater resources were evaluated for irrigation suitability using electrical conductivity (EC), sodium adsorption ratio, the US Salinity Laboratory diagram, sodium concentration, Wilcox’s diagram, Kelly’s index, and Doneen’s permeability index. EC and major ions were tested in recharge areas at different distances from the ARS. The construction of ARS at optimal distances along major streams has improved groundwater quantity and quality in the sub-basin. Before construction of ARS, fluoride concentrations were higher; after construction, fluoride was reduced in most locations. Water stored in the check dam and groundwater in the wells closer to the structure were suitable for both drinking and irrigation purposes. Impact of ARS on nearby groundwater quality was observed at Pallipatti, Mulayanur, Venkadasamuthram, Pudupatti, Poyyappatti, Harur1, and Sekkampatti. More distant sites included Pappiredipatti, Nambiyappati, Menasi, Harur, Todampatti, and Adikarapatti. Data demonstrated improved groundwater quality in the area of the ARS. Through recharge, the non-potable fluoride in the region is reduced to the permissible limit for human consumption.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
Most groundwater recharge in Tamil Nadu is from rainfall associated with the northeast monsoon. Groundwater development has accelerated in recent years, giving rise to the practice of managed aquifer recharge. The suitability of groundwater resources for drinking depends on various constituents, such as major and minor ions and dissolved inorganic, organic, radiological, and biological constituents. The Bureau of Indian Standards (BIS 2003) and the World Health Organization (WHO 2006) have prescribed permissible limits for various dissolved ions in water. In India, various groundwater recharge studies have been carried out based on these standards. Several researchers have discussed the mediating impact of artificial recharge structures (ARS) on groundwater fluoride concentrations (Patel 2002; Mudrakartha 2003; Bhagavan and Raghu 2005; Gale 2006; Palanisami et al. 2006; Bijukumar and Abraham 2009; Samarah et al. 2009; Venkateswaran 2010; Brindha and Elango 2012; Renganayaki and Elango 2013, 2014; Venkateswaran et al. 2015; Pazand 2016). Water quality is important not only in drinking water, but for irrigation as well—to ensure maximum yield from the crops. The concentration of dissolved ions must remain below the recommended permissible limits to ensure acceptable quality for drinking and irrigation. ARS are the most common form of water conservation, indirectly recharging aquifer systems in the sub-basin. In order to meet local water demand, ARS are constructed to store significant amounts of water. Existing ARS may impact groundwater quality irrespective of drainage systems and catchment areas. At present, the momentum is towards using monsoon runoff to recharge depleting aquifers, with no consideration for the water quality of the source water (Chadha 2014). Poor water quality can cause the recharging well to clog and the aquifers to become polluted with pathogens, causing water-borne diseases in the sub-basin. Additionally, various materials in the de-silting chambers can cause water quality problems to the recharged aquifers.
1.1 Details of study area
The study area is in the Vaniyar sub-basin of the Ponnaiyar River basin, southern India (Fig. 1). The Vaniyar River flows northeastward in the Dharmapuri district of Tamil Nadu. The amount of rainfall during the Southwest Monsoon is typically high, but can be highly variable. Major and minor ARS were constructed across major streams in the sub-basin. Rainfall is the major source of groundwater recharge in the sub-basin. Agricultural activity takes place throughout the year, and depends mainly on groundwater resources from dug wells and bore wells. The Tamil Nadu Water Supply and Drainage Board tap groundwater to supply water to the houses in nearby villages. The residents also use centrifugal pumps to tap additional groundwater for domestic purposes. Geologically, the study area is underlain mainly by charnockite and epidote-hornblende gneiss.
2 Methods and data collection
Historical groundwater quality data were collected from the public works department (PWD). To supplement historical data, samples were collected in the monsoon season and the wells were concurrently inspected to assess the well type. Groundwater samples were collected from in and around ARS in the sub-basin, and analyzed for pH; electrical conductivity (EC); and calcium, magnesium, sodium, potassium, carbonate, bicarbonate, chloride, fluoride, and sulfate concentrations. Groundwater level and EC were measured in all wells. Representative wells at various distances from the ARS were chosen for periodic evaluation.
3 Results and discussion
Groundwater quality was assessed for suitability for drinking based on fluoride and pH concentration across a diverse region of the study area as shown in Fig. 2. Historical data suggest fluoride in excess of the permissible limit can be attributed to over-withdrawal of groundwater and scarcity of rainfall. There was an increase in pH versus fluoride in some locations in the summer season and changes in fluoride were observed at Menasi, K. Vetripatti, and Kadattur. The worst water quality was observed at Kadattur in 2008 due to low rainfall. Fluoride and TDS concentration (Fig. 3), which are low value region indicated dilution in groundwater during rainy season. Minimum, maximum, and average of various parameters in groundwater quality are shown in Table 1.
Recharge areas were identified from the check dams in the region through assessment of total dissolved solids (TDS) and major ion concentrations (Renganayaki and Elango 2013). It is essential to safeguard water used for drinking and irrigation purposes. Maximum and minimum fluoride concentration are shown in Fig. 4. Both Salur and Kadattur recorded values >3 ppm, with values increasing with distance from the check dam.
3.1 Fluoride concentration
Analysis of groundwater samples revealed concentrations of fluoride in excess of permissible limits for drinking (Fig. 4). In most cases, the source is thought to be dissolution of fluoride-bearing minerals in granites and gneisses in the study area. It was also observed that deeper groundwater was more prone to fluoride contamination in comparison to the shallow weathered zone. High fluoride in groundwater due to the geologic environment is a considerable health problem in India and essential remedial measures are needed to combat an increasing occurrence of fluorosis, both dental and skeletal (CGWB 2008) TDS concentration decreased in groundwater by rainy season (Fig. 5).
3.2 Rainfall influence
Rainfall is a crucial climatic factor that influences water resources in seasonally variable parts of the world and its analysis an important prerequisite for agricultural planning in India (Alaka 1986). South India is a sub-tropical region where agriculture depends on monsoon rainfall, with more than 75% of rainfall occurring during the monsoon season. Monsoon rainfall is uneven both in time and space—important factors in groundwater recharge analysis. In 2008, with particularly low rainfall, Figs. 6, 7, and 8 indicate fluoride concentrations increased due to reduced recharge.
3.3 Groundwater quality for drinking purposes
Various parameters of groundwater quality are shown in Table 1. The abundance of major cation concentration in groundwater is Na > Ca > Mg > K, while that of anions is HCO3 > Cl > SO4 > CO3. The groundwater from near the ARS was of Na–Cl type. The average pH of groundwater around ARS was 7.49 and beyond in the check dam, it was 7.53. EC and TDS are important parameters, as prolonged use of drinking water with high EC may cause gastrointestinal irritation for humans (Singh et al. 2008). The EC of the groundwater samples in the study area ranged from 213 to 5162.67 µS/cm with an average of 1627.7. The prescribed limit of EC is 1500 µS/cm. The water quality types (Piper 1944) can be quickly identified by the location of points in different zones of the diamond shaped field (Fig. 9).
The suitability of groundwater for drinking purposes depends on pH and major ions remaining under the limits suggested by WHO (2006) and BIS (2003). After construction of ARS, pH and bicarbonate and sulfate concentrations in groundwater were found to be within the permissible limits as per WHO and BIS guidelines.
The minimum, maximum, and average total hardness were 134 (at Gopinathampatti), 1588 (at Samiyapuram), and 490.9 mg/L, respectively. The groundwater samples collected around ARS are shown in the Durov diagram (Fig. 10). Some drinking water samples in case 1 are Ca- and SO4-dominant, commonly indicative of recharge water in gypsiferous deposits; a mixed water or water exhibiting simple dissolution may be indicated. In case 2, there are no dominant anions or cations, indicating simple dissolution or mixing. In case 3, Cl and Na are dominant cations, indicating that the groundwater is related to reverse ion exchange of Na–Cl waters. In case 4, Cl and Na dominance normally indicate end-points of waters.
3.4 Groundwater quality for irrigation purposes
The pH of groundwater and water in the check dam was less than the prescribed 8.2 maximum limit for irrigation purposes (Ayers and Westcot 1994). EC is another important parameter to determine the quality of water for irrigation purposes. The water stored in the check dam was classified as good.
3.5 Sodium adsorption ratio
Excessive sodium in water reduces infiltration rates, causing adverse effects on soil aeration and seed germination, increasing weed growth, and promoting mosquito breeding due to waterlogging. The sodium adsorption ratio (SAR) helps to identify the sodium hazard.
According to Richards (1954), SAR is expressed in milliequivalents per liter as:
The classification of water samples from the study area based on SAR is given in Table 2. All water samples fell into the excellent category with respect to SAR, indicating there is no sodium hazard. The groundwater samples were classified into four types based on the United States Salinity Laboratory (USSL 1954) diagram (Fig. 11).
As shown in Fig. 11, 65% of all the groundwater samples fell into the C3–S1 type (high salinity and low sodium). The groundwater stored close to the ARS is two types: C2–S1 (medium salinity and low sodium) and C3–S1 (high salinity and low sodium water), both of which are suitable for irrigation.
3.6 Percentage sodium
It is important to classify irrigation water based on exchangeable sodium because excessive sodium affects both soil and crops, as explained earlier. In addition to SAR, percent Na is used to determine the effect of sodium. Percent Na is calculated using the formula:
where all concentrations are in milliequivalents per liter. The classification of water samples based on percent Na is given in Table 3. Of the groundwater samples, 8% were classified as excellent and 80% as good. Groundwater samples collected from in and around the ARS for groundwater quality were evaluated based on Wilcox’s (1955) plot, with the following samples achieving excellent ratings: Pappiredipatti, Nambiyampatti, Menasi, Pudupatti, Harur, Poyyappatti, Toddampatti, Harur1, Adikarapatti, and Sekkampatti (Fig. 12).
3.7 Kelly’s index
Kelly’s Index (KI) is based on the ratio of sodium to calcium and magnesium and is calculated using the following formula (Kelly 1963):
where all the ionic concentrations are expressed in milliequivalents per liter. Less calcium creates soil dispersion, which reduces the infiltration rate. The groundwater was classified based on KI as suitable in Nambiyampatti; marginal in Pappireddipatti, Sekkampatti and Poyyappatti; and unsuitable in Mulayanur, Adikarapatti, Harur1, Menasi, Harur, Pudupatti, Pallipatti, and Venkadasamuthram. Groundwater samples collected near the ARS were classified as marginally suitable for irrigation.
Concentrations of calcium and magnesium were used to calculate total hardness. The classification of groundwater based on hardness was suggested by Sawyer and McCarty (1967). Groundwater in this area was classified as moderately hard in Nambiyampatti, hard in Pappireddipatti, Poyyappatti, and Sekkampatti; and very hard in Pallipatti, Mulayanur Venkadasamuthram, Menasi Harur, Toddampatti, Harur1, and Adikarapatti. The minimum, maximum, and average were 133.1, 615, and 354.6 mg/L, respectively. The groundwater samples collected around ARS were suitable for drinking based on major ion concentrations.
3.8 Impact of artificial recharge structures on groundwater quality
In the study area, the quality of groundwater, based mainly on fluoride concentration, has been improved through dilution within about a 500 m radius of ARS (Fig. 13). Increased groundwater quality also improves the quality of soils; as a result, many farmers have benefited from ARS. Fluoride concentration was reduced in groundwater after construction of a check dam (Bhagavan and Raghu 2005), studied in Andhra Pradesh, India. Bijukumar and Abraham (2009) observed high concentrations of ions upstream in Peringottu Kurissi, India. Gale (2006) also noted improved groundwater quality in Satlasana, India, as did Mudrakartha (2003) in Gujarat, India. Salinity, arsenic, fluoride, and boron were diluted due to increased recharge. Palanisami et al. (2006) found ionic concentrations were reduced near a check dam in Tamil Nadu, India. Samarah et al. (2009) suggested the dilution of ions they observed was due to the presence of a check dam in Wadi Feifa, Jordan. Parimala Renganayaki and Elango (2013) reported dilution of EC, Na, and Cl in the groundwater near a well in Chennai, Tamil Nadu, India. In dilution through ARS, groundwater is improved at a rate much higher than under natural conditions through rainfall percolation during the monsoon.
Impact assessments of ARS on dilution of fluoride concentration in groundwater have been evaluated in the study area. Groundwater resources within 500 m of the ARS benefited from improved water quality in Pallipatti, Mulayanur, Venkadasamuthram, Pudupatti, Poyyappatti, Harur1, and Sekkampatti. All of these locations were identified as having safe drinking water, in contrast with more distant locations in Pappiredipatti, Nambiyappati, Menasi, Harur, Todampatti, and Adikarapatti. After the construction of ARS, reduced fluoride in groundwater was observed at Venkadasamutheram in the sub-basin. Bhagavan and Raghu (2005) also reported reduced fluoride concentrations in groundwater after construction of a check dam.
The EC and concentration of major ions were analyzed in both the benefited and non-benefited regions (Figs. 14, 15). Monitoring wells assessed for impact of ARS indicate a decrease in concentration of ions in groundwater due to recharge water. Due to low recharge beyond the selected ARS, no significant improvement in groundwater quality was observed in the region in terms of EC versus chloride.
Evaluation of groundwater quality recharged by ARS was conducted at Pallipatti, Mulayanur, Venkadasamuthram, Pudupatti, Poyapapatti, Harur, and Sekkampatti. More than 500 m from ARS, water quality was not benefitted at Pappiredipatti, Nambiyampatti, Menasi, Harur1, Todampatti, or Adhikarapatti. TDS within the permissible limit is evidence that artificial recharge of groundwater improved water quality in the sub-basin.
3.9 Effect of groundwater quality on check dam and percolation pond
Sample locations closer to ARS showed dilution of TDS and fluoride in the rainy season (Figs. 16, 17, 18, 19, 20, 21). Fluoride levels between 0.3 and 2.6 ppm were observed in Kadattur. Away from the check dam, fluoride concentrations were higher due to gneissic rocks, the weathering zone, and water level fluctuation; closer to the check dam, the fluoride concentrations were lower due to recharge of rainwater.
3.10 Field investigation
ARS were investigated in the field for functional character of the check dam and percolation pond and monitored for impact of recharge in groundwater as shown in Figs. 22 and 23.
3.11 Dental fluorosis
The prescribed range of fluoride in water for consumption is set to avoid conditions that lead to detrimental dental fluorosis in humans and animals (WHO 2004). People living in high-fluoride regions are certain to get dental staining. Teeth become dull, and yellow-white spots appear on the surface of teeth. Gradually, these spots turn brown and present as brown streaks closer to the tips of the teeth. In late stages, entire teeth become black. Teeth may be pitted or perforated and may even chip. In endemic zones, people lose their teeth at an early age (Fig. 24). Jagadeshan (2015) point out fluoride is naturally present due to weathering of rocks rich in fluoride, especially in type II wells. Groundwater from crystalline rocks, especially granites and gneisses are particularly likely to contain fluoride‐bearing minerals.
4 Conclusion
The quality of groundwater in and around selected ARS was evaluated for drinking and irrigation purposes. Silting in percolation ponds and check dams not only decreases the storage capacity but also reduces recharge in the sub-basin. ARS had greater effects downstream as compared to upstream in the sub-basin. The TDS of water is significantly less at the recharge structure and increases with distance due to dilution caused by ARS. The check dam and nearby wells in fluoride-affected areas showed a significant decrease in fluoride concentration, suggesting that recharge methods are effective in reducing fluorosis. The life of percolation tanks and check dams depend on de-silting by a geomorphologic agent. The success of recharge structures in Vaniyar sub-basin could be assessed in relation to height of water mound formed, areal extent of water spread both upstream and downstream of the structure, and water quality limits such as TDS and fluoride. With the installation of more recharge structures, there is a need to systematically evaluate their success.
References
Ayers RS, Westcot DW (1994) Water quality for agriculture. FAO Irrigation and drainage paper 29 Rev. 1. Accessed 14 Sept 2012
Bhagavan S, Raghu V (2005) Utility of check dams in dilution of fluoride concentration in groundwater and the resultant analysis of blood serum and urine of villagers, Anantapur district, Aandra Pradesh, India. Environ Geochem Health 27(1):97–108
Bijukumar A, Abraham KM (2009) Impact of Peringottukurissi Check Dam on Hydrography of Bharatapuzha River, Kerala. J Inland Fisheries Soc 41(1)
BIS (2003) Bureau of indian standards specification for drinking water. IS:10500:91. Revised 2003. Bureau of Indian Standards, New Delhi
CGWB (2008) Impact assessment of demonstrative project on artificial recharge to ground water in Gangavalli Block, Salem District, Tamil Nadu, Technical Report, Central Ground Water Board, South Eastern Coastal Region Chennai
Chadha DK (2014) Water conservation and artificial recharge of aquifers in India. Bol Geol Min 125(2):203–218
Gadagil A (1986) Annual and weekly analysis of rainfall and temperature for Pune: a multiple time series approach. Inst. Indian Geographers
Gale IN (2006) Managed aquifer recharge: lessons learned from the agrar study
Jagadeshan G (2015) Kalpana, Elango L (2015) Major ion signatures for identification of geochemical reactionsresponsible for release of fluoride from geogenic sourceto groundwater and associated risk in Vaniyar River basin, Dharmapuri district, Tamil Nadu, India. Environ Earth Sci 74:2439–2450. doi:10.1007/s12665-015-4250-9
Kelly WP (1963) Use of saline irrigation water. Soil Sci 95(4):355–391
Mudrakartha S (2003) Augmenting groundwater resources by artificial recharge at Aravalli Hills, Gujarat
Palanisami K, Raviraj A, Thirumurthi S (2006) Artificial recharge in hard rock areas of Coimbatore district–a case study.(IGC-2006). Accessed 15 June 2010
Patel AS (2002) Impact of groundwater recharge activities in Saurashtra, IWMI-Tata Water Policy Research Program
Pazand K (2016) Geochemistry and multivariate statistical analysis for fluoride occurrence in groundwater in the Kuhbanan basin, Central Iran. Model Earth Syst Environ. doi:10.1007/s40808-016-0127-5
Piper AM (1944) A graphical procedure in the geochemical interpretation of water analysis. Trans Am Geophys Union 25:914–928
Renganayaki SP, Elango L (2013) A review on managed aquifer recharge by check dams: a case study near Chennai, India, ISSN, 2319–1163
Renganayaki SP, Elango L (2014) Impact of recharge from a check dam on groundwater quality and assessment of suitability for drinking and irrigation purposes. Arab J Geosci 7:3119–3129
Richards LA (1954) Diagnosis and improvement of saline and alkaline soils (p. 60). US Department of Agriculture hand book, Washington DC
Samarah M, Momani MA, Any RT, Jiries A, Naqa AL (2009) Evaluation of water quality of groundwater recharge in Wadi Feifa, Southern Jordan Valley. 13thInternational Water Technology Conference, IWTC 13, 2009, Hueghada
Sawyer CN, McCarty DL (1967) Chemistry for sanitary engineers, 2nd edn. McGraw Hill, New York, p 518
Singh AK, Mondal GC, Kumar S, Singh TB, Tewary BK, Sinha A (2008) Major ion chemistry, weathering processes and water quality assessment in upper catchment of Damodar River basin, India. Environ Geol 54:745–758
United States Salinity Laboratory Staff (USSL) (1954) Diagnosis and improvement of saline and alkali soils. US Department of Agriculture Handbook 60, Washington DC, p 147
Venkateswaran S (2010) Hydrogeology and geochemical characterisation of groundwater with special emphasis on agricultural development in Vaniyar sub-basin, Ponnaiyar river, Tamil Nadu. Int J Recent Sci Res 1(12):213–221
Venkateswaran S, Satheeshkumar S, Kannan R (2015) Impact assessment of water table fluctuations in and around artificial recharge structures in Vaniyar sub-basin of the Ponnaiyar River, South India. Int J Recent Sci 6(7):5480–5486
WHO (2006) Guideline for drinking water quality: recommendation volume.1. World Health Organization, Geneva, p 130
Wilcox LV (1955) Classification and use of irrigation waters. Circular 969. USDA, Washington, DC
Acknowledgements
The authors express their sincere thanks to the Natural Resources Data Management System (NRDMS), of the Department of Science and Technology (DST), New Delhi, India for providing financial support and to the Public Works Department (PWD), Tamil Nadu, India for providing necessary data to complete this research work in the Department of Geology, Periyar University, Salem-11.This report has benefited greatly from the detailed comments and suggestions provided by the editors and the anonymous reviewers.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Satheeshkumar, S., Venkateswaran, S. & Kannan, R. Temporary fluoride concentration changes in groundwater in the context of impact assessment in the Vaniyar sub-basin, South India. Acta Geochim 36, 112–123 (2017). https://doi.org/10.1007/s11631-016-0137-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11631-016-0137-z