Abstract
3D printing allows product customisation to be cost efficient. This presents opportunity for innovation. This study investigated the effects of two modifications to the locking compression plate (LCP), an established orthopaedic implant used for fracture fixation. The first was to fill unused screw holes over the fracture site. The second was to reduce the Young’s modulus by changing the microarchitecture of the LCP. Both are easily customisable with 3D printing. Finite element (FE) models of a fractured human tibia fixed with 4.5/5.0 mm LCPs were created. FE simulations were conducted to examine stress distribution within the LCPs. Next, a material sweep was performed to examine the effects of lowering the Young’s modulus of the LCPs. Results showed at a knee joint loading of 3× body weight, peak stress was lowered in the modified broad LCP at 390.0 MPa compared to 565.1 MPa in the original LCP. It also showed that the Young’s modulus of material could be lowered to 50 GPa before the minimum principal stresses increased exponentially. These findings suggested the modifications could lead to improved performances of fracture fixation, and therefore likely that other orthopaedic implants survivorship could also be enhanced by customisation via 3D printing.
Similar content being viewed by others
References
Sniderman B, Mahto M, Cotteleer MJ (2016) Industry 4.0 and manufacturing ecosystems. In: Deloitte University Press. https://www2.deloitte.com/content/dam/insights/us/articles/manufacturing-ecosystems-exploring-world-connected-enterprises/DUP_2898_Industry4.0ManufacturingEcosystems.pdf
Davies R (2015) Industry 4.0 digitalisation for productivity and growth. In: European Parliamentary Research Service Briefing September 2015. http://www.europarl.europa.eu/RegData/etudes/BRIE/2015/568337/EPRS_BRI(2015)568337_EN.pdf
Gerbert P, Lorenz M, Rüβmann M, Waldner M, Justus J, Engel P, Harnisch M (2015) Industry 4.0: the future of productivity and growth in manufacturing industries Boston Consulting Group. https://www.bcg.com/publications/2015/engineered_products_project_business_industry_4_future_productivity_growth_manufacturing_industries.aspx
3D Printing of Medical Devices. U.S. Food and Drug Administration. https://www.fda.gov/medicaldevices/productsandmedicalprocedures/3dprintingofmedicaldevices/default.htm
Hasenboehler E, Rikli D, Babst R (2007) Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibia fracture: a retrospective study of 32 patients. Injury 38(3):365–370
Wagner M (2003) General principles for the clinical use of the LCP. Injury 34:31–42
Huiskes R, Weinans H, Van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 274:124–134
Pfeiffer FM (2016) The use of finite element analysis to enhance research and clinical practice in orthopaedics. J Knee Surg 29(2):149–158
Rho JY, Hobatho M, Ashman RB (1995) Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17(5):347–355
Losertová M, Štamborská M, Lapin J, Mareš V (2016) Comparison of deformation behavior of 316L stainless steel and Ti6Al4V alloy applied in traumatology. Metalurgija 55(4):667–670
Gervais B, Vadean A, Raison M, Brochu M (2016) Failure analysis of a 316L stainless steel femoral orthopaedic implant. Eng Fail Anal 5-6:30–38
Mohammad KA, Ali A, Sahari BB, Abdullah S (2012) Fatigue behavior of austenitic type 316L stainless steel. In: IOP conference series: materials science and engineering. IOP Publishing
Huang JY, Yeh JJ, Jeng SL, Chen CY, Kuo RC (2006) High-cycle fatigue behavior of type 316L stainless steel. Mater Trans 47(2):409–417
Brunner H, Simpson JP (1980) Fatigue fracture of bone plates. Injury 11(3):203–207
Rüedi TP, Buckley R, Moran CG (2007) AO principles of fracture management. Ann R Coll Surg Engl 91(5):448–449
Tack P, Victor J, Gemmel P, Annemans L (2016) 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online 15(1):115
Wenger R, Oehme F, Winkler J, Perren SM, Babst R, Beeres FJP (2017) Absolute or relative stability in minimal invasive plate osteosynthesis of simple distal meta or diaphyseal tibia fractures? Injury 48(6):1217–1223. https://doi.org/10.1016/j.injury.2017.03.005
Pauwels F (1980) Biomechanics of the locomotor apparatus, 1st edn. Springer-Verlag, Berlin Heidelberg New York
Stoffel K, Klaue K, Perren SM (2000) Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury 31(Suppl 2):S-B37–S-B50
Tavares SSM, Mainier FB, Zimmerman F, Freitas R, Ajus CMI (2010) Characterization of prematurely failed stainless steel orthopaedic implants. Eng Fail Anal 17:1246–1253
Azevedo CRF, Hippert E Jr (2002) Failure analysis of surgical implants in Brazil. Eng Fail Anal 9:621–633
Marcomini JB, Baptista CARP, Pascon JP, Teixeira RL, Reis FP (2014) Investigation of a fatigue failure in a stainless steel femoral plate. J Mech Behav Biomed Mater 38:52–58
Rho JY, Ashman RB, Turner CH (1993) Young’s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech 26(2):111–119
Mavčič B, Antolič V (2012) Optimal mechanical environment of the healing bone fracture/osteotomy. Int Orthop 36:689–695
Navarro M, Michiardi A, Castaño O, Planell J (2008) Biomaterials in orthopaedics. J R. Soc Interface 5(27):1137–1158. https://doi.org/10.1098/rsif.2008.0151
Santorinaios M, Brooks W, Sutcliffe CJ, Mines RAW (2006) Crush behaviour of open cellular lattice structures manufactured using selective laser melting. WIT TRANS BUILT ENV 85:481–490
Heinl P, Müller L, Körner C, Singer RF, Müller FA (2008) Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting. Acta Biomater 4:1536–1544
Reinhart G, Teufelhart S, Riss F (2012) Investigation of the geometry-dependent anisotropic material behaviour of filigree struts in ALM-produced lattice structure. Phys Procedia 39:471–479
Tang Y, Zhou Y, Hoff T, Garon M, Zhao YF (2016) Elastic modulus of 316 stainless steel lattice structure fabricated via binder jetting process. Mater Sci Technol 32:648–656
Funding
This study was supported by National Additive Manufacturing Innovation Cluster @ National University of Singapore (NAMIC@NUS) through a project funding with ID 2016013.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that there is no conflict of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Yan, L., Lim, J.L., Lee, J.W. et al. Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation. Med Biol Eng Comput 58, 921–931 (2020). https://doi.org/10.1007/s11517-019-02104-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-019-02104-9