The establishment of crystal position look-up table for positron emission tomography with block detectors

  • Published:
Science in China Series E: Technological Sciences Aims and scope Submit manuscript

Abstract

A method has been developed to establish the crystal position look-up table for positron emission tomography with block detectors. It is based on the principle that the counts in crystal position histogram obey the Gaussian mixture model (GMM). This method has taken full consideration of the characteristics of the GMM and the detector itself. The experimental results have proved that it is simple, reliable, and universal.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Tang X W. Functional Imaging of the Brain (in Chinese). Hefei: University of Science and Technology of China Press, 1999. 5–38

    Google Scholar 

  2. Dahlbom M, Hoffman E J. An evaluation of a two-dimensional array detector for high resolution PET. IEEE Trans Med Imag, 1988, 7(4): 264–271

    Article  Google Scholar 

  3. Rogers J G, Taylor A J, Rahimi M F, et al. An improved multicrystal 2-D BGO detector for PET. IEEE Trans Nucl Sci, 1992, 39(4): 1063–1068

    Article  Google Scholar 

  4. Cutler P D, Hoffman E J. Use of digital front-end electronics for optimization of a modular PET detector. IEEE Trans Med Imag, 1994, 13(2): 408–418

    Article  Google Scholar 

  5. Young J W, Moyers J C, Lenox M. FPGA based front-end electronics for a high resolution PET scanner. IEEE Trans Nucl Sci, 2000, 47(4): 1676–1680

    Article  Google Scholar 

  6. Stronger K A, Johnson M T. Optimal calibration of PET crystal position maps using Gaussian mixture models. IEEE Trans Nucl Sci, 2004, 51(1): 85–89

    Article  Google Scholar 

  7. Casey M E, Nutt R. A multislice two dimensional BGO detector system for PET. IEEE Trans Nucl Sci, 1986, NS-33: 760–763

  8. Yoshida E, Kimura Y, Kitamura K, et al. Calibration procedure for a DOI detector of high resolution PET through a Gaussian mixture model. IEEE Trans Nucl Sci, 2004, 51(5): 2543–2549

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to BaoCi Shan.

Additional information

Supported by the National High-Tech Research and Development Program of China (“863”) (Grant No. 2006AA020803)

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chai, P., Shan, B. The establishment of crystal position look-up table for positron emission tomography with block detectors. Sci. China Ser. E-Technol. Sci. 52, 2418–2423 (2009). https://doi.org/10.1007/s11431-008-0235-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11431-008-0235-1

Keywords

Navigation