Skip to main content
Log in

New DOI Detector Using a Bottom and Side Readouts with a Cross-Arranged Scintillator Array for Positron Emission Tomography

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

We designed a depth-encoding positron emission tomography (PET) detector by using a bottom and side readout method with a cross-arranged scintillator array. To evaluate the characteristics of the novel detector module, we used the DETECT2000 simulation tool to perform the optical photon transport in the crystal array. The detector module consists of an M (column) × N (row) cross-arranged crystal array composed of M/3 sub-arrays consisting of N × 3 crystals. The second column of the sub-array is arranged perpendicular to the first and the third columns. The crystal is optically coupled to the crystals of the other columns; however, the surfaces between the crystals in the same column are treated as reflectors. A 6 × 5 crystal array consisting of two sub-arrays was considered for proof of concept. The two multi-pixel photon counter (MPPC) arrays are coupled to the bottom and one side of the crystal array, respectively. The x-y position is determined by the bottom MPPC array, and the side MPPC array gives depth information. All pixels in the x-y plane and the z direction were clearly distinguished.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. H. Peng and C. S. Levin, Curr. Pharm. Biotechnol. 11, 555 (2010).

    Article  Google Scholar 

  2. R. S. Miyaoka, T. K. Lewellen, H. Yu and D. L. Mc-Daniel, IEEE Trans. Nucl. Sci. 45, 1069 (1998).

    Article  ADS  Google Scholar 

  3. S. R. Cherry, J. A. Sorenson and M. E. Phelps, Physics in Nuclear Medicine, 3rd ed. (Saunders, Philadelphia, 2003).

    Google Scholar 

  4. W. W. Moses, S. E. Derenzo, C. L. Melcher and R. A. Manente, IEEE Trans. Nucl. Sci. 42, 1085 (1995).

    Article  ADS  Google Scholar 

  5. K. C. Burr, A. Ivan, D. E. Castleberry, J. W. LeBlanc, K. S. Shah and R. Farrell, IEEE Trans. Nucl. Sci. 51, 1791 (2004).

    Article  ADS  Google Scholar 

  6. Y. Shao, X. Sun, K. A. Lan, C. Bircher, K. Lou and Z. Deng, Phys. Med. Bio. 59, 1223 (2014).

    Article  Google Scholar 

  7. A. Mohammadi, E. Yoshida, F. Nishikido, M. Nitta, K. Shimizu, T. Sakai and T. Yamaya, Phys. Med. Bio. 63, 025019–1 (2018).

    Article  Google Scholar 

  8. M. Ito, S. J. Hong and J. S. Lee, Biomed. Eng. Lett. 1, 70 (2011).

    Article  Google Scholar 

  9. Y. Yang, J. Qi, Y. Wu, S. St. James, R. Farrell, P. A. Dokhale, K. S. Shah and S. R. Cherry, Phys. Med. Bio. 54, 433 (2009).

    Article  Google Scholar 

  10. F. Cayouette, D. Laurendeau and C. Moisan, Proc. SPIE 4833, 69 (2003).

    Article  ADS  Google Scholar 

  11. https://doi.org/www.hamamatsu.com/resources/pdf/ssd/s13360_series_kapd1052e.pdf.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Cheol-Ha Baek.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lee, SJ., Baek, CH. New DOI Detector Using a Bottom and Side Readouts with a Cross-Arranged Scintillator Array for Positron Emission Tomography. J. Korean Phys. Soc. 73, 1904–1907 (2018). https://doi.org/10.3938/jkps.73.1904

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.73.1904

Keywords

Navigation