Abstract
Objectives
To assess the presence, location, and course of the incisive canal and the presence of the anterior loop using cone beam computed tomography (CBCT) in a selected Iranian population.
Methods
Mandibular CBCT scans of 84 patients were examined for preoperative planning of implant placement. The scans were taken using a NewTom VG CBCT unit. After reconstruction of panoramic and buccolingual cross-sectional images with 1-mm thickness, the presence of the incisive canal and the anterior loop was determined. The canal was colorized and the distances (d) from the incisive canal to the tooth apex (d1), buccal plate (d2), lingual plate (d3), and inferior border of the mandible (d4) were measured in regions containing the first premolar, canine, lateral, and central teeth.
Results
The incisive canal and the anterior loop were visible in 92.3 and 36.9% of the scans, respectively. No significant differences between the presence of the incisive canal and the anterior loop were detected on the basis of patient sex or side of the mandible. A significant difference between the visibility of the anterior loop and age groups (≤40 and >40 years) was detected. However, no significant differences existed between the measurements in the tooth regions examined in the two age groups. The most common location of the canal in the first premolar–canine regions was a buccal location.
Conclusions
CBCT is effective for identifying the incisive canal and the anterior loop. In most cases, no significant differences exist between the distance measurements on the right and left sides.
Similar content being viewed by others
References
Juodzbalys G, Wang H-L. Guidelines for the identification of the mandibular vital structures: practical clinical applications of anatomy and radiological examination methods. J Oral Maxillofac Res. 2010;1:el.
Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ. Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res. 2003;14:464–71.
Markis N, Stamatakis H, Syriopoulos K, Tsiklakis K, van der Stelt PF. Evaluation of the visibility and the course of the mandibular incisive canal and the lingual foramen using cone-beam computed tomography. Clin Oral Implants Res. 2010;21:766–71.
Jacobs R, Mraiwa N, van Steenberghe D, Gijbels F, Quirynen M. Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan. Dentomaxillofac Radiol. 2002;31:322–7.
Jacobs R, Lambrichts I, Liang X, Martens W, Mraiwa N, Adriaensens P, et al. Neurovascularization of the anterior jaw bones revisited using high-resolution magnetic resonance imaging. Oral Surg Oral Pathol Oral Radiol Endod. 2007;103:683–93.
Von Arx T, Häfliger J, Chappuis V. Neurosensory disturbances following bone harvesting in the symphysis: a prospective clinical study. Clin Oral Implants Res. 2005;16:432–9.
Walton JN. Altered sensation associated with implants in the anterior mandible: a prospective study. J Prosthet Dent. 2000;83:443–9.
Hunt DR, Jovanovic SA. Autogenous bone harvesting: a chin graft technique for particulate and monocortical bone blocks. Int J Periodontics Restor Dent. 1999;19:165–73.
Wismeijer D, van Waas MA, Vermeeren JI, Kalk W. Patients’ perception of sensory disturbances of the mental nerve before and after implant surgery: a prospective study of 110 patients. Br J Oral Maxillofac Surg. 1997;35:254–9.
Hofschneider U, Tepper G, Gahleitner A, Ulm C. Assessment of the blood supply to the mental region for reduction of bleeding complications during implant surgery in the interforaminal region. Int J Oral Maxillofac Implants. 1999;14:379–83.
Mordenfeld A, Andersson L, Bergström B. Hemorrhage in the floor of the mouth during implant placement in the edentulous mandible: a case report. Int J Oral Maxillofac Implants. 1997;12:558–61.
Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol. 2004;33:291–4.
Pires CA, Bissada NF, Becker JJ, Kanawati A, Landers MA. Mandibular incisive canal: cone beam computed tomography. Clin Implant Dent Relat Res. 2009. doi:10.1111/j.1708-8208.2009.00228.x.
Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H, et al. Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg. 2009;67:744–50.
Uchida Y, Yamashita Y, Goto M, Hanihara T. Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region. J Oral Maxillofac Surg. 2007;65:1772–9.
Mraiwa N, Jacobs R, Moerman P, Lambrichts I, van Steenberghe D, Quirynen M. Presence and course of the incisive canal in the human mandibular interforaminal region: two-dimensional imaging versus anatomical observations. Surg Radiol Anat. 2003;25:416–23.
Jacobs R, Mraiwa N, Van Steenberghe D, Sanderink G, Quirynen M. Appearance of the mandibular incisive canal on panoramic radiographs. Surg Radiol Anat. 2004;26:329–33.
Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M. Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants. 2008;23:919–25.
Ngeow WC, Dionysius DD, Ishak H, Nambiar P. A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups. J Oral Sci. 2009;51:231–7.
Arzouman MJ, Otis L, Kipnis V, Levine D. Observations of the anterior loop of the inferior alveolar canal. Int J Oral Maxillofac Implants. 1993;8:295–300.
Yosue T, Brooks SL. The appearance of mental foramina on panoramic radiographs. I. Evaluation of patients. Oral Surg Oral Med Oral Pathol. 1989;68:360–4.
Mardinger O, Chaushu G, Arensburg B, Taicher S, Kaffe I. Anterior loop of the mental canal: an anatomical-radiologic study. Implant Dent. 2000;9:120–5.
Acknowledgments
We are grateful to Drs. Mohammad Moshtaghi Moghadam and Gholamhossein Adham for making recommendations and Mrs. Maryam Shakiba for her help in the data analysis. In addition, we would like to thank Julie Monti Safari for her assistance in editing the text.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kajan, Z.D., Salari, A. Presence and course of the mandibular incisive canal and presence of the anterior loop in cone beam computed tomography images of an Iranian population. Oral Radiol 28, 55–61 (2012). https://doi.org/10.1007/s11282-012-0084-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11282-012-0084-2