Trace Determination of Cadmium in Water Matrix by Matrix Matching Calibration Strategy-Based UV-Vis Spectrophotometer After Its Preconcentration

  • Published:
Water, Air, & Soil Pollution Aims and scope Submit manuscript

Abstract

In this study, an analytical method based on UV-Vis spectrophotometer was developed for the determination of trace amounts of cadmium in tap water samples. The analyte in samples to be analyzed was firstly preconcentrated using the liquid-liquid microextraction method. (Z)-4-bromo-2[(naphthalene-2-ylimino)-methyl]phenol was used as a complexing agent in the microextraction process. Parameters affecting the efficiency of the liquid-liquid microextraction (LLME) process applied for preconcentration were optimized before starting the analysis. As a result of the analysis performed under the determined optimum conditions, linearity was observed between 0.050 and 4.0 mg/L. The detection limit was calculated as 0.017 mg/L as a result of eight repetitive analysis with the lowest concentration of cadmium in the linear region. The efficiency of our method in real samples was determined by recovery studies. As a result of the experiments performed on the tap water samples, the percent recovery values varied between 92 and 117%. These results are quite satisfactory in terms of demonstrating the applicability/accuracy of the method in the real sample.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Data Availability

Data will be available on reasonable request.

References

Download references

Author information

Authors and Affiliations

Authors

Contributions

Ozan Yağmuroğlu: formal analysis; investigation; methodology; validation; visualization; roles/writing—original draft

Emine Gülhan Bakırdere: preparation of ligand; methodology; roles/writing—original draft

Sezgin Bakırdere: conceptualization; investigation; supervision; validation; writing—review and editing

Corresponding author

Correspondence to Ozan Yağmuroğlu.

Ethics declarations

Ethical Responsibilities of Authors

All authors have read, understood, and have complied as applicable with the statement on “Ethical responsibilities of Authors” as found in the Instructions for Authors.

Competing Interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yağmuroğlu, O., Bakırdere, E.G. & Bakırdere, S. Trace Determination of Cadmium in Water Matrix by Matrix Matching Calibration Strategy-Based UV-Vis Spectrophotometer After Its Preconcentration. Water Air Soil Pollut 235, 171 (2024). https://doi.org/10.1007/s11270-024-06978-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s11270-024-06978-w

Keywords