Guaiacol (GUA) and pholcodine (PHO) were simultaneously determined in a pharmaceutical syrup using RP-HPLC with UV detection. The separation was performed using X-Bridge C8 column (100 mm × 4.6 mm, 2.5 μm particle size) and a mobile phase of acetonitrile – phosphate buffer (pH 6.8; 50 mM) (25:75, v/v) at a flow rate of 0.55 mL/min. The column temperature was adjusted to 35°C, and the detector was set to measure the absorbance at 238 nm. The ICH guidelines were followed to validate the method. The linearity was studied over 6.0 – 70 μg/mL and 4 – 420 μg/mL ranges for GUA and PHO, respectively. Linear relationships were obtained over the specified concentration ranges with correlation coefficients of 0.9989 for GUA and 0.9999 for PHO. The limits of detection were also determined and found to be 2 μg/mL for GUA and 1.2 μg/mL for PHO. The proposed method was applied for the determination of both drugs in Coughpent syrup; the results comply with the label claim (0.1572g/120mL for PHO and 0.0237g/120mL for GUA).
Similar content being viewed by others
References
N. Sarma, G. Giancaspro, and J. Venema, Drug Test. Anal., 8, 418 – 423 (2016).
C. M. Judkins, P. Teale, and D. J. Hall, Drug Test. Anal., 2, 417 – 420 (2010).
I. A. Revelsky, E. S. Chernetsova, B. P. Luzyanin, et al, Drug Test. Anal., 2, 452 – 454 (2010).
A. L. N. van Nuijs, A. Gheorghe, P. G. Jorens, et al, Drug Test. Anal., 6, 861 – 867 (2014).
M. Sundström, A. Pelander, K. Simojoki, and I. Ojanperä, Drug Test. Anal., 8, 39 – 45 (2016).
A. Maas, B. Madea, and C. Hess, Drug Test Anal, 1 – 18 (2017).
T. Launiainen, I. Nupponen, E. Halmesmäki, and I. Ojanperä, Drug Test. Anal., 5, 529 – 533 (2013).
A. Petkovska, H. Babunovska, and M. Stefova, Maced. J. Chem. Chem. Eng., 30, 139 – 150 (2011).
B. Shi and H. Min, Chinese Pharm. Aff., 4, 23 – 29 (2011).
X. Wang, L. Zhang, D. Byrne, L. et al, Org. Lett., 16, 4090 – 4093 (2014).
A. A. Moustafa, M. A. Hegazy, D. Mohamed, and O. Ali, J. AOAC Int., (2017).
J. Acevska, A. Dimitrovska, G. Stefkov, et al, J. AOAC Int., 95, 399 – 405 (2012).
A. A. Moustafa, H. Salem, M. Hegazy, and O. A. Mahmoud, J. Planar Chromatogr. – Mod. TLC, 28, 307 – 315 (2015).
S. A. Mir, A. A. Ahangar, and A. S. Bhat, Int. J. PharmTech Res., 5, 341 – 348 (2013).
K. S. Bahçeci and J. Acar, Eur. Food Res. Technol., 225, 873 – 878 (2007).
M. Hachiya, N. Asanome, T. Goto, and T. Noda, Japan Agric. Res. Q. JARQ, 43, 193 – 198 (2009).
Y. Hayasaka, G. A. Baldock, K. H. Pardon, et al, J. Agric. Food Chem., 58, 2076 – 2081 (2010).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mansour, F.R., Khairy, M.A. Stability Indicating RP-HPLC Method for Simultaneous Determination of Pholcodine and Guaiacol in Pharmaceutical Syrup. Pharm Chem J 53, 775–779 (2019). https://doi.org/10.1007/s11094-019-02078-w
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11094-019-02078-w