The key problem facing the application of FRP stay cables and tendons is the anchor age. In the first part of the investigation, a model of a potted (bond-type) anchor was proposed, and a parametric analysis of the solution for the distribution of the interfacial shear stress in side the anchor with a sleeve of constant thickness was made. In this, second part, the solution is generalized to consider sleeves with a variable thickness (stepped and tapered), and the parametric analysis is extended. All the results obtained are compared, and the most effective means for decreasing the peak interfacial shear stress in the anchor are high lighted.
Similar content being viewed by others
References
G. G. Portnov, C. E. Bakis, and V. L. Kulakov, “Assessment of transmission of the shear stress in potted anchors for composite rods: 1. Sleeve of constant thickness,” Mech. Compos. Mater., 45, No. 3, 217-234 (2009).
R. D. Adams, J. Comyn, and W. C. Wake, Structural Adhesive Joints in Engineering, Chapman & Hall, London (1997).
Author information
Authors and Affiliations
Additional information
Russian translation published in Mekhanika Kompozitnykh Materialov, Vol. 45, No. 4, pp. 555-578, July-August, 2009.
Rights and permissions
About this article
Cite this article
Portnov, G.G., Bakis, C.E. & Kulakov, V.L. Assessment of transmission of the shear stress in potted anchors for composite rods. 2. Sleeve of variable thickness. Mech Compos Mater 45, 381–398 (2009). https://doi.org/10.1007/s11029-009-9099-0
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11029-009-9099-0