Skip to main content
Log in

Measurement of the Efficiency of Detection by Single-Photon Counters Based on Avalanche Photodiodes by the Method of Spontaneous Parametric Down Conversion with Spectrally Asymmetric Channels

  • Published:
Measurement Techniques Aims and scope

We consider a frequency-diaphragm technique of simultaneous standardless measurements of the efficiency of photon detection by two single-photon counters. This technique is based on the well-known scheme of measurements of the efficiency of detection of single photons with the help of photon pairs generated in a nonlinear crystal in the case of spontaneous parametric scattering. As a specific feature of the proposed procedure, we can mention the application of spectrally asymmetric optical channels. An experimental installation aimed at the realization of the proposed procedure in the degenerate mode of spontaneous parametric scattering is described. The results of simultaneous measurements of the detection efficiency of two single-photon counters at a wavelength of 810 nm are presented. The counters are constructed on the basis of SAP-500 silicon avalanche photodiodes with fiber inputs. It is shown that this technique can be also used for measuring the detection efficiency of single-photon counters sensitive in a more long-wave region of the spectrum. As compared with the pure diaphragm scheme, the proposed procedures has advantages in the simplicity and reliability of adjustment.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.

Similar content being viewed by others

References

  1. S. A. Magnitskiy, D. N. Frolovtsev, D. P. Agapov, et al., “Metrology of single photons for quantum information technologies,” Izmer. Tekhn., No. 3, 24–29 (2017).

  2. D. C. Burnham and D. L. Weinberg, “Observation of simultaneity in parametric production of optical photon pairs,” Phys. Rev. Lett., 25, No. 2, 84–87 (1970).

    Article  ADS  Google Scholar 

  3. A. N. Penin and A. Sergienko, “Absolute standardless calibration of photodetectors based on quantum two-photon fields,” Appl. Opt., 30, No. 25, 3582–3588 (1991).

    Article  ADS  Google Scholar 

  4. P. G. Kwiat, A. M. Steinberg, R. Y. Chiao, et al., “Absolute efficiency and time-response measurement of single-photon detectors,” Appl. Opt., 33, No. 10, 1844–1853 (1994).

    Article  ADS  Google Scholar 

  5. V. M. Ginzburg, N. G. Keratishvili, Ye. L. Korzhenevich, et al., “Absolute measurement of quantum efficiency based on parametric down-conversion effect,” Metrologia, 30, No. 4, 367–368 (1993).

    Article  ADS  Google Scholar 

  6. A. Migdall, R. Datla, A. V. Sergienko, et al., “Measuring absolute infrared spectral radiance with correlated visible photons: technique verification and measurement uncertainty,” Appl. Opt., 37, No. 16, 3455–3463 (1998).

    Article  ADS  Google Scholar 

  7. G. Brida, S. Castelletto, C. Novero, and M. L. Rastello, “Quantum-efficiency measurement of photodetectors by means of correlated photons,” JOSA B, 16, No. 10, 1623–1627 (1999).

    Article  ADS  Google Scholar 

  8. M. Stipčević, H. Skenderović, and D. Gracin, “Characterization of a novel avalanche photodiode for single photon detection in VISNIR range,” Opt. Express., 18, No. 16, 17448–17459 (2010).

    Article  ADS  Google Scholar 

  9. M. Ware and A. Migdall, “Single-photon detector characterization using correlated photons: the march from feasibility to metrology,” J. Modern Optics, 51, Nos. 9–10, 1549–1557 (2004).

  10. A. P. Worsley, H. B. Coldenstrodt-Ronge, J. S. Lundeen, et al., “Absolute efficiency estimation of photon-number resolving detectors using twin beams,” Opt. Express, 17, No. 6, 4397–4412 (2009).

    Article  ADS  Google Scholar 

  11. A. Avella, G. Brida, I. P. Degiovanni, et al., “Self-consistent, absolute calibration technique for photon number resolving detectors,” Opt. Express, 19, No. 23, 23249–23257 (2011).

    Article  ADS  Google Scholar 

  12. J. Peřina, Jr., O. Haderka, A. Allevi, and M. Bondani, “Absolute calibration of photon-number-resolving detectors with an analog output using twin beams,” Appl. Phys. Lett., 104, No. 4, 041113-1–041113-4 (2014).

  13. L. Cohen, Y. Pilnyak, D. Istrati, et al., “Absolute calibration of single-photon and multiplexed photon-number-resolving detectors,” Phys. Rev. A, 98, No. 1, 013811-1–013811-8 (2018).

  14. S. Magnitskiy, D. Frolovtsev, V. Firsov, et al., “An SPDC-based source of entangled photons and its characterization,” J. Russ. Laser Res., 36, No. 6, 618–629 (2015).

    Article  Google Scholar 

  15. A. L. Migdall, “Absolute quantum effi ciency measurements using: toward a measurement protocol,” IEEE Trans. Instrum. Measur., 50, No. 2, 478–481 (2001).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. V. Demin.

Additional information

Translated from Izmeritel’naya Tekhnika, No. 12, pp. 27–32, December, 2018.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gostev, P.P., Agapov, D.P., Demin, A.V. et al. Measurement of the Efficiency of Detection by Single-Photon Counters Based on Avalanche Photodiodes by the Method of Spontaneous Parametric Down Conversion with Spectrally Asymmetric Channels. Meas Tech 61, 1166–1173 (2019). https://doi.org/10.1007/s11018-019-01565-6

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11018-019-01565-6

Keywords

Navigation