Introduction

Radiation sterilisation has been successfully used in the food, cosmetic and pharmaceutical industry [1]. The need for testing the radiochemical stability of medical therapy drugs follows from the possible application of the bactericidal effect of ionising radiation in the process of their sterilisation in the solid state [2, 3] in drug formulation [3] and in water solutions [4]. The mechanism of bactericidal effect of ionising radiation can be either direct (damage to cell macromolecules) or indirect (water radiolysis) and the final effect is inhibition of living functions of bacteria and their endospores [1, 5]. Unfortunately, ionising radiation besides the bactericidal effect can change the active substance of the drug which may lead to the loss of pharmacological activity or even the appearance of harmful effect [2]. The irradiation caused changes most often observed in drugs include the formation of free radicals and products of decomposition, discolouration, changes in the crystal lattice and/or crystal structure [6]. For the above-reasons it is necessary to determine the radiochemical stability of therapeutic drugs and check the possibility of their sterilisation by irradiation.

The aim of this study was determination of the radiochemical stability of three derivatives of methylxanthine (caffeine, theophilline and theobromine) in solid phase. The drugs are used in medical treatment often in the form of injections so they must be sterile.

The three derivatives of methylxanthine in solid phase were irradiated with ionising radiation produced by a beam of electrons of energy 9.96 MeV in the doses of 25, 50, 100, 200 and 400 kGy, and then subjected to analytical examination. According to the European Norm EN 552 [7], the dose recommended for radiation sterilisation is 25 kGy, but the use of higher doses in our experiment followed from the fact that after irradiation with higher doses the possible changes are more pronounced and the content of the radiolysis products is increased so easier to detect. To check if the three derivatives of methylxanthine could be safely sterilised by irradiation, the drugs non-irradiated and irradiated with different doses were subjected to examination by HPLC, EPR and DSC methods.

Materials and methods

Materials

Characterisations of the investigated caffeine CF (serial number 014K0036, content 101.2 %), theophylline TP (serial number 192077, content 99.91 %) and theobromine TB (serial number 055K2519, content 99.94 %) are presented in Table 1. All investigated substances were in the form of white, loose powder and obtained from Sigma–Aldrich.

Table 1 Chemical properties of methylxanthine derivatives [8]

Exposure to irradiation

Approximately 1.0 g of TB and TP and 0.5 g of CF was placed in a colourless glass vial of 5 ml in capacity and closed with a plastic stopper. The samples in the vials were exposed to irradiation in a linear electron accelerator LAE 13/9 (electron beam 9.96 MeV and current intensity 6.2 μA) till they had absorbed a dose of 25, 50, 100, 200 and 400 kGy.

Differential scanning calorimetry (DSC)

Measurements were performed on an apparatus DSC-204 made by Netzsch. Samples of 3 mg were closed in aluminium crucibles with pierced lids. Before measurements, the samples were thermally equilibrated at 20 °C for 5 min, and the measurements were performed at the heating rate of 5 °C min−1, in helium atmosphere (40 mL min−1). For each sample, three independent measurements were performed and the results were averaged. The data were analyzed using TA Netzsch programme. For determination of enthalpy values characterizing phase transitions, a linear or a tangent-sigmoidal baseline was used.

High-performance liquid chromatography (HPLC)

The HPLC system consisted of a Waters Model 616 solvent pump system equipped with a Photodiode Array UV–Vis Waters 996 detector set at 272 nm for TF and 273 nm for CF and TB. Chromatographic separation was performed with a Xterra C18 reverse phase column (3.9 × 150 mm, 2.5 μm particle size), and the mobile phase was phosphate buffer-acetonitrile 80:20 v/v at a flow rate of 1 mL min−1. The separation was conducted at room temperature.

Electron paramagnetic resonance (EPR)

The EPR experiments were carried out for all non-irradiated, irradiated samples, in standard EPR quartz sample tubes from Wilmad. The measurements were performed with a Bruker EPR EMX-10 spectrometer working at 9.4 GHz (X-band) at room temperature (293 K). The sensitivity of the spectrometer was 1 × 1010 spins g−1. Induction of the magnetic field was measured to the accuracy of 0.001 mT. Microwave frequency was measured to the accuracy of 0.001 GHz. The spectra were double integrated over the magnetic field range 334–354 mT, which gives a figure proportional to the number of radicals in the sample.

Results and discussion

An interesting observation was that the methylxanthine derivatives studied did not change the colours upon irradiation with ionising radiation produced by a beam of electrons of energy 9.96 MeV, in the doses of 25, 50, 100, 200 and 400 kGy. It is unusual as very often ionising radiation causes change in colour. The change in colour is explained by the formation of colour products of decomposition (absorbing light in visual range and giving colour solutions) or by a damage to the crystal lattice and formation of the so-called colour centres or F centres also absorbing light in visual range. The F centres are made by anion voids with an electron captured inside. Formation of more complex electron trapping centres is possible made of a few F centres. As the crystal must remain neutral, the formation of colour centres is accompanied by the formation of hole centres known also as V centres [9].

The lack of change in colour in the methylxanthine derivatives studied upon irradiation with a dose of 400 kGy, so 16-times higher than the standard sterilisation dose, suggested that these compounds must be exceptionally resistant to ionising radiation. Changes in colour (from white to light yellow) upon irradiation with 25 kGy have been observed for pilocarpine hydrochloride [10]. Also a change in colour upon irradiation has been observed for chloramphenicol sodium succinate, but for this compound it was accompanied by granulation and a change in the degree of crystallinity [11].

As no change in colour was observed upon irradiation of methylxanthine derivatives studied, to detect possible products of decomposition of these compound the HPLC method was applied (Fig. 1). Table 2 presents the contents of the active substance (methylxanthine derivatives) in the samples subjected to irradiation determined by HPLC. For CF and TF irradiated with doses from 25 to 100 kGy, the loss in content was less than 1 %, while upon irradiation with 200 and 400 kGy, the loss in content did not exceed 1.20 %. For TB, the loss in content upon irradiation with 25 kGy was 1.20 % and increased to 2.58 % upon irradiation with 400 kGy.

Fig. 1
figure 1

HPLC chromatograms of methylxanthine derivatives before and after irradiation with the dose of 400 kGy

Table 2 Results of HPLC analysis of the methylxanthines studied

In comparison to the loss in content upon irradiation observed for other drugs [6, 11] the loss in content for the methylxanthine derivatives was exceptionally small, which means that their radiodegradation was indeed not much, even after irradiation with 400 kGy. For many drugs subjected to ionising radiation the dose-dependent losses in content have been observed reaching even a few 10% [6, 11].

The very small changes in the content upon irradiation of the methylxanthine derivatives studied were probably a consequence of their simple chemical structure making a compact system of two rings and the lack of longer or branched substituents.

Besides HPLC measurements, the methylxanthine derivatives were also subjected to DSC analyses. The DSC method is very useful for quick assessment of radiochemical stability of drugs in solid state. This application of DSC is based on the van Hoff equation indicating that the melting point of a compound containing impurities (i.e. all other chemical compounds besides the active substance, including the products of the active substance radiodegradation) is always lower than that of the pure compound. Thus, for the drugs of low-radiochemical stability and easily undergoing radiodegradation the DSC peak corresponding to melting is shifted towards lower temperatures, which is related to the presence of the products of degradation. The usefulness of DSC for this purpose has been tested many times for some groups of drugs, e.g. betalactam antibiotics, derivatives of azole, imidazole, phenylpropanol, sulphonamides, certain alkaloids and others [1018].

For the methylxanthine derivatives studied, no changes in the character of DSC curves were observed upon their irradiation that could testify to the presence of radiolysis products or changes in the physicochemical properties of the compounds studied (Fig. 2). For TP and TB one endothermic peak was observed near the melting point of the relevant compounds (at ~272 °C for TP and at ~349 °C for TB). For CF besides the solid → liquid (~236 °C) phase transition also a change in the polymorphic form was noted at about 160 °C. According to the literature on thermal investigation of methylxanthine derivatives [19], the course of their DSC curves is characteristic of anhydrous forms and the curve recorded for CF also implies that this derivative occurs in the polymorphic form α CF (form II), while the peak appearing at ~160 °C corresponds to the transition of CF into a new polymorphic form (form I).

Fig. 2
figure 2

DSC curves recorded for the methylxanthines studied prior to and after irradiation

As a result of irradiation the character of the DSC curves recorded did not change and only slight changes in the values of T peak and T onset were noted (Table 3). The most pronounced differences in these temperatures before and after irradiation were detected for CF irradiated with a dose of 400 kGy, ΔT onset = −1.0 °C and ΔT peak = −0.8 °C. Similarly as the lack of colour changes and HPLC results, these small changes in T onset and T peak implied high-radiochemical stability of the three compounds studied.

Table 3 Results of DSC analysis of the methylxanthines studied

As ionising radiation results first of all in emission of electrons as a consequence of the photoelectric phenomenon and Compton effect leading to free radicals generation, the above-compounds studied were subjected to qualitative and quantitative EPR analysis. The generation of free radicals is on the one hand responsible for damage to biological structures of micro-organisms and is one of the main bactericidal mechanisms involved in radiation sterilisation, but on the other hand ionising radiation generates free radicals also in the therapeutic drug. If this happens the free radicals initiate degradation of the drug and can lead to a number of undesirable effects.

In non-irradiated derivatives of methylxanthine studied no presence of free radicals was detected, and after the irradiation with a dose of 25 kGy their EPR spectra were characterised by low intensity (Fig. 3). The EPR spectrum of CF revealed a hyperfine structure, while the spectrum of TB was anisotropic. For CF, TP and TB the amounts of unpaired spins were 4.27 × 1014, 3.82 × 1014 and 5.23 × 1014 spin g−1, and the gyromagnetic coefficient (g factor) are 2.0029, 2.0043 and 2.0054, respectively.

Fig. 3
figure 3

EPR spectra of methylxanthine derivatives before and immediately after irradiation with the dose of 25 kGy

Conclusions

As follows from the above-presented and discussed results, the methylxanthine derivatives studied in solid phase show relatively high-radiochemical stability upon irradiation with the doses applied. From among them CF and TP are a bit more resistant to the ionising radiation than TB, for which the decrease in content after irradiation with 400 kGy was 2.58 % (HPLC), the decrease in content of CF and TP was within the error of the method.

Analysis of the chemical structure of the compounds studied suggests that the methyl substituent at N1 in CF and TP is responsible for their greater radiochemical stability than that of TB which has no substituent at this position. It is supposed that the presence of the substituent at N1 blocks the transformation of the molecule to the enol form, which may be an important protection against radiodegradation.

Against the background of the hitherto results concerning radiochemical stability of mediac therapy drugs, methylxanthines belong to the compounds exceptionally resistant to ionising radiation. Many drugs have shown a gamut of changes in the physical properties (change in colour, change in crystallisation degree and change in chirality) and chemical properties (oxidation, cleavage of chemical bonds, dehydrogenation, formation of free radicals) after irradiation with a minimum dose. The changes were often directional and intensified with increasing dose of irradiation [10, 13, 2028]. For many irradiated drugs also a shift of the melting point was observed towards lower temperatures which was related to the appearance of the products of irradiation (Table 4). For some drugs linear relations were observed between the decrease in the melting point and increase in the irradiation dose as well as between the decrease in the melting point and decrease in content of the active substance.

Table 4 Changes in the melting points of some groups of drugs upon ionising radiation produced by E-beam

The very small decrease in the melting point observed by DSC and small changes measured by other methods allow us to conclude that sterilisation by irradiation can by applied to these compounds. Methylxanthines are probably one of the therapeutic drugs most resistant to ionising radiation emitted by a beam of electrons.