Skip to main content
Log in

Fast determination of 90Sr using liquid scintillation counter based on shielding package

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A novel method for direct measurement of 90Sr in liquid samples was developed by using liquid scintillation counter. Based on the shielding performance analysis and the optimum package investigation, the proposed method provides an excellent shielding for the interferences of α-emitters, low- and intermediate-energy β-emitters. A minimum detection activity of 8.0 ± 0.6 Bq·L−1 for 90Sr was obtained. Due to the effective elimination of the quenching interference and counting interference, the method presented in this work can provide the results of 90Sr analysis within 1 h after receiving the sample.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Pittet PA, Bochud F, Froidevaux P (2019) Determination of 89Sr and 90Sr in fresh cow milk and raw urine using crystalline synthetic tunnel manganese oxides and layered metal sulfides. Anal Chim Acta 1047:267–274

    Article  CAS  Google Scholar 

  2. Forsberg S, Strandmark M (2001) Migration and chemical availability of 137Cs and 90Sr in swedish long-term experimental pastures. Water Air Soil Pollut 127:157–171

    Article  CAS  Google Scholar 

  3. Froidevaux P, Bochud F, Haldimann M (2018) Retention half time in the skeleton of plutonium and 90Sr from above-ground nuclear tests: a retrospective study of the Swiss population. Chemosphere 80:519–524

    Article  Google Scholar 

  4. L’Annunziata MF (1998) Handbook of radioactivity analysis. Academic Press, San Diego

    Google Scholar 

  5. Rao DD, Mehendarge ST, Chandramouli S, Hegde AG, Mishra UC (2000) Application of Cherenkov radiation counting for determination of 90Sr in environmental samples. J Environ Radioact 48:49–57

    Article  CAS  Google Scholar 

  6. Vaca F, Manjon G, Garcia-Leion M (1998) Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting. Nucl Instrum Methods Phys Res A 406:267–275

    Article  CAS  Google Scholar 

  7. Tsroya S, Pelled O, German U, Marco R, Katorza E, Alfassi ZB (2009) Color quench correction for low level Cherenkov counting. Appl Radiat Isot 67:805–808

    Article  CAS  Google Scholar 

  8. Tarancón A, Alonso E, Garća JF, Rauret G (2002) Comparative study of quenching correction procedures for 90Sr/90Y determination by Cerenkov, liquid scintillation and plastic scintillation techniques. Anal Chim Acta 471:135–143

    Article  Google Scholar 

  9. Mosqueda F, Villa M, Vaca F, Bolıvar JP (2007) Colour quenching corrections on the measurement of 90Sr through Cerenkov counting. Anal Chim Acta 604:184–190

    Article  CAS  Google Scholar 

  10. Rivera-Silva J, Hurtado-Bermúdez S, Villa-Alfageme M, Manjón G (2019) Comparison and validation of methods for the determination of 90Sr by Cerenkov counting in biological and sediment samples, including green chemistry metrics. J Radioanal Nucl Chem 320:109–122

    Article  CAS  Google Scholar 

  11. Stamoulis KC, Ioannides KG, Karamanis DT, Patiris DC (2007) Rapid screening of 90Sr activity in water and milk samples using Cherenkov radiation. J Environ Radioact 93:144–156

    Article  CAS  Google Scholar 

  12. Yang Y, Song L, Luo M, Dai X, Guo X (2017) A rapid method for determining 90Sr in leaching solution from cement solidification of low and intermediate level radioactive wastes. J Radioanal Nucl Chem 314:477–482

    Article  CAS  Google Scholar 

  13. Tayeb M, Dai X, Corcoran EC, Kelly DG (2014) Evaluation of interferences on measurements of 90Sr/90Y by TDCR Cherenkov counting technique. J Radioanal Nucl Chem 300:409–414

    Article  CAS  Google Scholar 

  14. Kabai E, Hornung L, Savkin BT, Poppitz-Spuhler A, Hiersche L (2011) Fast method and ultra fast screening for determination of 90Sr in milk and dairy products. Sci Total Environ 410–411:235–240

    Article  Google Scholar 

  15. Maxwell SL III, Culligan BK (2009) Rapid separation method for emergency water and urine samples. J Radioanal Nucl Chem 279:901–907

    Article  CAS  Google Scholar 

  16. Tenjović B, Stojković I, Nikolov J, Todorović N, Spasojević J, Agbaba J, Pajić M, Krmar M (2019) 90Sr/90Y determination in milk by Cherenkov radiation after microwave digestion. J Radioanal Nucl Chem 320:679–687

    Article  Google Scholar 

  17. Feng X-G, He Q-g, Jing-Chen J-C, Chen J (2014) Modified 2-window approach for rapid determination of 90Sr and 90Y at low quench level using liquid scintillation counting. J Radioanal Nucl Chem 299:509–516

    Article  CAS  Google Scholar 

  18. Dai X, Cui Y, Kramer-Tremblay S (2013) A rapid method for determining strontium-90 in urine samples. J Radioanal Nucl Chem 296:363–368

    Article  CAS  Google Scholar 

  19. Grau Carles A, Rodriguez Barquero L, Grau Malonda A (1993) Standarzation of multi- nuclide mixtures by a new spectrrum unfolding method. J Radioanal Nucl Chem 176(5):391–403

    Article  CAS  Google Scholar 

  20. Hong KH, Cho YH, Lee MH, Choi GS, Lee CW (2001) Simultaneous measurement of 89Sr and 90Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method. Appl Radiat Isot 54:299–305

    Article  CAS  Google Scholar 

  21. Olfert JM, Dai X, Kramer-Tremblay S (2014) Rapid determination of 90Sr/90Y in water samples by liquid scintillation and Cherenkov counting. J Radioanal Nucl Chem 300:263–267

    Article  CAS  Google Scholar 

  22. Brun S, Kergadallan Y, Boursier B, Fremy JM, Janin F (2003) Methodology for determination of radiostrontium in milk: a review. Dairy Sci Technol 83(1):1–15

    Article  CAS  Google Scholar 

Download references

Acknowledgements

We gratefully acknowledge the financial support from the National Nature Science Foundation of China (Project No. 21103139).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiufang Zhai.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhai, X., Fan, J., Dong, J. et al. Fast determination of 90Sr using liquid scintillation counter based on shielding package. J Radioanal Nucl Chem 331, 2911–2917 (2022). https://doi.org/10.1007/s10967-022-08360-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-022-08360-8

Keywords

Navigation