Skip to main content
Log in

Activity standardization of 99mTc using liquid scintillation counting method

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The Korea Research Institute of Standards and Science (KRISS) participated in the BIPM.RI(II)-K4.Tc-99 m comparison of activity measurements of 99mTc. We develop the national primary standard for 99mTc solution used during the comparison. We use two primary liquid scintillation counting techniques for the standardization: digital coincidence counting with the 4πβ(LS)-γ(NaI(T1))system and triple-to-double coincidence ratio counting. Both methods give consistent results for the specific activity of a 99mTc solution. Adopting the result from the DCC method as the reference value of the 99mTc measurement, we evaluate the standard uncertainty of 0.856% for the KRISS primary standard of the 99mTc activity. The K4 comparison result shows that the newly-established KRISS primary standard lies within the standard uncertainty with the key comparison reference value defined from other 99mTc measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Lee KB, Lee JM, Park TS, Oh PJ, Lee SH, Lee MK (2011) Application of digital sampling techniques for 4πβ(LS)-γ coincidence counting. Nucl Instrum Methods Phys Res, Sect A 626–627:72–76

    Article  CAS  Google Scholar 

  2. Lee KB, Lee JM, Park TS, Lee SH (2010) Development of a high-efficiency 4πβ(LS)-γ coincidence system for direct measurements of activity in radioactive decay. IEEE Trans Nucl Sci 57(5):2613–2616

    Article  CAS  Google Scholar 

  3. Lee KB, Lee JM, Park TS, Hwang HY (2004) Implementation of TDCR method in KRISS. Nucl Instrum Methods Phys Res, Sect A 534(3):496–502

    Article  CAS  Google Scholar 

  4. DDEP (2004) Decay data evaluation project data. http://www.nucleide.og/DDEP_WG/Nuclides/Tc-99m_tables.pdf

  5. Lee KB, Lee JM, Park TS, Lee SH (2010) Construction of classical confidence regions of model parameters in nonlinear regression analyses. Appl Radiat Isot 68(7–8):1261–1265

    Article  CAS  PubMed  Google Scholar 

  6. Bar J, Sempau J, Fernndez-Varea JM, Salvat F (1995) Penelope: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter. Nucl Instrum Methods Phys Res, Sect B 100(1):31–46

    Article  Google Scholar 

  7. Michotte C, Park TS, Lee KB, Lee JM, Lee SH (2012) Comparison of 99mTc activity measurements at the KRISS using the new SIRTI of the BIPM. Appl Radiat Isot 70(9):1820–1824

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. B. Lee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lee, K.B., Lee, J.M., Park, T.S. et al. Activity standardization of 99mTc using liquid scintillation counting method. J Radioanal Nucl Chem 316, 1047–1052 (2018). https://doi.org/10.1007/s10967-018-5884-3

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-018-5884-3

Keywords

Navigation