Abstract
The characterization and ray-tracing algorithm in ISOCS/LabSOCS has been extended to calculate full energy peak and total efficiencies for the Small Anode Germanium Well detector. The extension allows for true coincidence summing correction using the standard algorithm in the Genie 2000 software. The accuracy of the full energy peak efficiency calculation and the coincidence summing correction has been experimentally validated to be the same as for non-well detectors.
Similar content being viewed by others
References
Adekola AS, Colaresi J, Douwen J, Mueller WF, Yocum KM (2014) Performance of a Small Anode Germanium Well detector. Nucl Instrum Meas A. doi:10.1016/j.nima.2014.12.034
LeBlanc PJ, Bronson F, Mueller WF, Russ W, Venkataraman R (2013) Mathematical efficiency calibration methods for high quality laboratory based gamma spectrometry systems. J Radioanal Nucl Chem 296(2):1045–1049 doi:10.1007/s10967-012-2209-9
Venkataraman R, Bronson F, Atrashkevich V, Field M, Young BM (2005) Improved detector response characterization method in ISOCS and LabSOCS. J Radioanal Nucl Chem 264:213–219
Briesmeister JF (2000) MCNP—A General Monte Carlo N-Particle Transport Code version 4c. no LA-13709-M, Los Alamos National Laboratory. http://library.lanl.gov/cgi-bin/getfile?la-13709.htm
Agostinelli S, Allison J, Amako K, Apostolakis J, Araujoa H, Arce P, Asai M, Axen D, Banerjee S, Barrand G, Behner F, Bellagamba L, Boudreau J, Broglia J, Brunengo A, Burkhardt H, Chauvie S, Chuma J, Chytracek R, Cooperman G, Cosmo G, Degtyarenkod P, Dell’Acqua A, Depaola G, Dietrich D, Enami R, Feliciello A, Ferguson C, Fesefeldt H, Folger G, Foppiano F, Forti A, Garelli S, Giani S, Giannitrapani R, Gibin D, Gómez Cadenas JJ, González I, Gracia Abril G, Greeniaus G, Greiner W, Grichine V, Grossheim A, Guatelli S, Gumplinger P, Hamatsu R, Hashimoto K, Hasui H, Heikkinen A, Howard A, Ivanchenko V, Johnson A, Jones FW, Kallenbach J, Kanaya N, Kawabata M, Kawabata Y, Kawaguti M, Kelner S, Kent P, Kimura A, Kodama T, Kokoulin R, Kossov M, Kurashige H, Lamann E, Lampén T, Lara V, Lefebure V, Lei F, Liendl M, Lockman W, Longo F, Magni S, Maire M, Medernach E, Minamimoto K, Mora de Freitas P, Morita Y, Murakami K, Nagamatu M, Nartallo R, Nieminen P, Nishimura T, Ohtsubo K, Okamura M, O’Neale S, Oohata Y, Paech K, Perl J, Pfeiffer A, Pia MG, Ranjard F, Rybin A, Sadilov S, Di Salvo E, Santin G, Sasaki T, Savvas N, Sawada Y, Scherer S, Sei S, Sirotenko V, Smith D, Starkov N, Stoecker H, Sulkimo J, Takahata M, Tanaka S, Tcherniaev E, Safai Tehrani E, Tropeano M, Truscott P, Uno H, Urban L, Urban P, Verderi M, Walkden A, Wander W, Weber H, Wellisch JP, Wenaus T, Williams DC, Wright D, Yamada T, Yoshida H, Zschiesche D (2003) Geant4—a simulation toolkit. Nucl Instrum Methods A 506:250–303
Moens L, De Corte F, Simonits A, Xilei Lin, De Wispelaere A, De Donder J, Hoste J (1982) Calculation of the absolute peak efficiency of Ge and Ge(Li) detectors for different counting geometries. J Radioanal Nucl Chem 70:539–550
Mueller WF, Bronson F, Field M, Morris K, Nakazawa D, Venkataraman R, Atrashkevich V (2009) Challenges and techniques to effectively characterize the efficiency of broad-energy germanium detectors at energies less than 45 keV. J Radioanal Nucl Chem. doi:10.1007/s10967-009-0273-6
Jäderström H, Mueller WF, Atrashkevich V, Adekola AS (2014) True coincidence summing correction and mathematical efficiency modeling of a well detector. Nucl Instrum Meas A. doi:10.1016/j.nima.2014.08.032
Moens L (1981) Doctorate Thesis, University of Gent
DeCorte F (1987) Doctorate Thesis, University of Gent
Kolotov VP, Atrashkevich V, Gelsema SJ (1996) Estimation of true coincidence correction for voluminous sources. J Radioanal Nucl Chem 210:183–196
Kolotov VP, Koskelo MJ (1998) Testing of different true coincidence correction approaches for gamma-ray spectrometry of voluminous sources. J Radioanal Nucl Chem 233:95–100
Russ W, Venkataraman R, Bronson F (2005) Validation testing of the Genie 2000 Cascade Summing Correction. J Radioanal Nucl Chem 264:193–197
Zhu H, Morris K, Mueller W, Field M, Venkataraman R, Lamontagne J, Bronson F, Berlizov A (2009) Validation of true coincidence summing correction in Genie 2000 V3.2. J Radioanal Nucl Chem. doi:10.1007/s10967-009-0148-x
Zhu H, Venkataraman R, Mueller W, Lamontagne J, Bronson F, Morris K, Berlizov A (2009) X-ray true coincidence summing correction in Genie 2000. Appl Radiat Isot 67:696–700
Nudat 2.6 National nuclear data center Brookhaven national laboratory www.nndc.bnl.gov/nudat2. Accessed 10 Apr 2015
Mueller WF, Ilie G, Lange HJ, Rotty M, Russ WR (2013) In-situ measurement and analysis of naturally occurring radioactive material. In: Proceeding for the ANIMMA conference 2013
Venkataraman R, Bronson F, Atrashkevich V, Young BM, Field M (1999) Validation of in situ object counting system (ISOCS) mathematical efficiency calibration software. Nucl Instrum Methods A 422:450–454
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jäderström, H., Adekola, A.S., Atrashkevich, V. et al. Experimental verification of mathematical efficiency modeling and true coincidence summing correction of the SAGe Well detector. J Radioanal Nucl Chem 307, 1961–1966 (2016). https://doi.org/10.1007/s10967-015-4572-9
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-015-4572-9