Abstract

A new method is presented to calculate with improved accuracy the absolute peak efficiency of cylindrical Ge and Ge(Li) detectors for point, disk and cylinder sources, positioned at any source-detector distance. Moreover attention was paid to true-coincidence effects. The method is extensively tested and applied for the analysis of reference materials. The accuracy turned out to be 3% or better.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. U. PROESCH, M. LUTHARDT, L. KOLDITZ, Isotopenpraxis, 15 (1979) 297.

    CAS  Google Scholar 

  2. C. C. GROSJEAN, Nucl. Instr. Methods, 17 (1962) 289.

    Article  Google Scholar 

  3. R. L. HEATH, Scintillation Spectrometry, Gamma-Ray Spectrum Catalogue, 2nd ed., USAEC Report IDO-16880, 1964.

  4. D. C. CAMP, A. L. VAN LEHN, Nucl. Instr. Methods, 76 (1969) 192.

    Article  CAS  Google Scholar 

  5. R. GRIFFITHS, Nucl. Instr. Methods, 91 (1971) 377.

    Article  CAS  Google Scholar 

  6. R. GUNNINK, J. B. NIDAY, Computerized Quantitative Analysis by Gamma-Ray Spectrometry Vol. 1 Description of the Gammanal Program, USAEC Report UCRL-51061, 1972.

  7. J. E. CLINE, A Technique of Gamma-Ray Detector Absolute Efficiency Calibration for Extended Sources, Proc. of the Am. Nucl. Soc. Topical Conference at Mayaguez, Puerto Rico, 1978, CONF-780421, 1979, p. 185.

  8. MASAYASU NOGUCHI, KENJI TAKEDA, HIDEA HIGUCHI, Int. J. Appl. Radiat. Isotopes, 32 (1981) 17.

    Article  CAS  Google Scholar 

  9. G. AUBIN, J. BARRETTE, G. LAMOUREUX, S. MONARO, Nucl. Instr. Methods, 76 (1969) 85.

    Article  CAS  Google Scholar 

  10. S. N. KAPLANIS, Int. J. Appl. Radiat. Isotopes, 29 (1978) 543.

    Article  Google Scholar 

  11. BIAGIO ARCIPIANI, EDMONDO PEDRETTI, Atomkernenergie/Kerntechnik, 35 (1980) 210.

    CAS  Google Scholar 

  12. I. R. WILLIAMS, Nucl. Instr. Methods, 44 (1966) 160.

    Article  Google Scholar 

  13. L. MOENS, J. DE DONDER, LIN XILEI, F. DE CORTE, A. DE WISPELAERE, A. SIMONITS, J. HOSTE, Nucl. Instr. Methods, 187 (2,3) (1981).

  14. D. S. ANDREEV, K. I. EROKHINA, V. S. ZVONOV, I. Kh. LEMBERG, Instr. Expt. Techn., 15 (1972) 1358.

    Google Scholar 

  15. L. MOENS et al., (in preparation).

  16. A. SIMONITS, L. MOENS, F. DE CORTE, A. DE WISPELAERE, A. ELEK, J. HOSTE, J. Radioanal. Chem., 60 (1980) 461.

    Article  CAS  Google Scholar 

  17. L. MOENS, F. DE CORTE, A. SIMONITS, A. DE WISPELAERE, A. ELEK, J. HOSTE, (in preparation).

  18. L. MOENS, Doctorate Thesis, Rijksuniversiteit Gent, 1981.

  19. LIN XILEI, Doctorate Thesis, Rijksuniversiteit Gent, 1981.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Research associate of the “Nationaal Fonds voor Wetenschappelijk Onderzoek”.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moens, L., De Corte, F., Simonits, A. et al. Calculation of the absolute peak efficiency of Ge and Ge(Li) detectors for different counting geometries. J. Radioanal. Chem. 70, 539–550 (1982). https://doi.org/10.1007/BF02516136

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02516136

Keywords

Navigation