Skip to main content
Log in

Calibration of Power Systems and Measurements of Discharge Currents Generated for Different Coils in the EGYPTOR Tokamak

  • Published:
Journal of Fusion Energy Aims and scope Submit manuscript

Abstract

The EGYPTOR tokamak is a small device of rectangular cross section 25 × 20 cm. Its major (R) and minor (A) radius are 30 and 10 cm, respectively. The aspect ratio is 3. The present work is devoted to measure the absolute values of the discharge currents and to calibrate the different power systems used to supply different coils in the tokamak. Two different methods are applied to measure the discharge currents from different capacitor banks. The first is the direct method employing a calibrated resistance R=0.008 Ω; this resistance was prepared and calibrated in the IPP of the Czech Academy of Sciences, Czech Republic. The second is the indirect method using a calibrated Rogowski coil, fabricated and calibrated also in Prague (Czech Rogowski coil). Both methods are applied simultaneously. Details of each power system presently used are reported. Sensitivity calibration of two different Rogowski coils is also done, and comparison with the calculated sensitivity shows good agreement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.
Fig. 9.
Fig. 10.
Fig. 11.
Fig. 12.
Fig. 13.
Fig. 14.
Fig. 15.
Fig. 16.
Fig. 17.
Fig. 18.
Fig. 19.
Fig. 20.

Similar content being viewed by others

REFERENCES

  1. Robinson D. C., (1993). Plasma Phys. Control Fusion 35:B91–B104

    Article  Google Scholar 

  2. Sometani T., Fujisawa N., (1978). Plasma Phys. 20:1101

    Article  Google Scholar 

  3. A. B. El Sisi and H. Hegazy, J. Fusion Energy, 22, 191 (September 2003) (@2004)

  4. Brevnov N., Gott Yu., (2000). The Tokamak Egyptor Problem Analysis and Recommendations concerning its Smooth Operation. PRC, Kurchatov Institute, Russia

    Google Scholar 

  5. R. Flohr, C. Gillet, J. Hackmann, G. Reinhold, G. Ritter, J. Uhlenbusch, and S. Zakaria, SFB PlasmaPhysik BOCHUM/Jülich Report No. 80-01-064, (1980)

  6. J. Wesson, TOKAMAKS, (Clarendon Press Oxford, 1987)

Download references

ACKNOWLEDGMENTS

This work was a part of a joint research between the IPP, Czech Academy of sciences, Czech Republic and the Egyptian Atomic Energy Authority and partially funded by IAEA-CRP joint research using small Tokamaks, contract number EGY 12937.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Hegazy.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hegazy, H., Zacek, F. Calibration of Power Systems and Measurements of Discharge Currents Generated for Different Coils in the EGYPTOR Tokamak. J Fusion Energ 25, 73–86 (2006). https://doi.org/10.1007/s10894-006-9010-0

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10894-006-9010-0

Keywords

Navigation