Avoid common mistakes on your manuscript.
Editor:
A recent investigation by Cheong and colleagues should pique the interest of all clinicians who employ sonography during resuscitation [1]. In their report, a novel method of measuring the left common carotid artery, maximum velocity time integral (VTIMAX-CA) was described and its value was related to the left ventricular outflow tract VTI (VTILVOT). Absolute VTI measurements (in centimeters) were made in critically-ill patients, though the population studied was relatively stable, seemingly not on vasoactive medications and with normal cardiac function. Importantly, there was no provocative (i.e., dynamic) maneuver carried out during their investigation.
As anticipated, Cheong and colleagues observed a stronger relationship between total (i.e., systolic plus diastolic) VTIMAX-CA and VTILVOT than between only the systolic portion of the VTIMAX-CA and the VTILVOT. Of most interest, however, was the near parity between VTIMAX-CA and VTILVOT in absolute value. Based on their regression equation, the VTIMAX-CA overestimated the VTILVOT less than 10%. Considering why this might be so elaborates some caveats to their approach.
1 The maximum-to-centroid velocity ratio
What escapes some clinical sonographers is that the VTI of hemodynamic interest is not the maximum VTI, but rather the ‘centroid’ VTI (VTICENT). The centroid velocity is a ‘power weighted,’ average velocity across the vessel lumen [2,3,4]. Importantly, the relationship between VTICENT and the maximum VTI (VTIMAX) depends upon the velocity profile within the vessel [2, 3]. In ‘plug flow’ conditions (e.g., LVOT, ascending aorta), the velocity profile is flat such that maximum and centroid velocities are nearly identical [5]. Accordingly, the maximum-to-centroid ratio is roughly 1.0 at the LVOT. By contrast, ‘parabolic flow’ is characterized by a maximum velocity double that of the centroid velocity (i.e., a max-to-centroid ratio of 2.0) [2]. This occurs in smaller-diameter vessels where the centerline red blood cell (RBC) velocity is greatest and there is progressive slowing of the RBCs towards the lumen periphery; however, few vessels in the body are characterized by fully-developed, parabolic flow [5]. The velocity profile of the carotid artery, for instance, is characterized as ‘blunted parabolic,’ with a max-to-centroid ratio approximately mid-way between 1.0 and 2.0 [4]. Given the above, we can express the following relationship as Eq. (1).
where K = 1.0 in plug flow; K = 2.0 in parabolic flow and K \(\approx\) 1.5 in blunted parabolic flow.
Using the wireless, wearable Doppler system developed by our group [6,7,8,9,10], we have observed that in resting, healthy volunteers, the common carotid artery max-to-centroid ratio falls between 1.5 and 1.7 over the entire cardiac cycle. Thus, for simplicity we assume that the VTIMAX-CA is 1.6 times the carotid artery centroid VTI (VTICENT-CA); that is, K = 1.6 and we express Eq. (2):
Furthermore, we assume that the velocity profile in the left ventricular outflow tract is plug; thus, Eq. 3:
In other words, the LVOT maximal velocity is used interchangeably with the LVOT centroid velocity.
2 Relationship between LVOT and carotid artery VTI
The stroke volume (in mL or cm3) is calculated with ultrasound by multiplying the cross-sectional area (CSA) of the LVOT (in cm2) by the VTILVOT (in cm) (Eq. 4) [11]:
The volume of the SV that moves up a carotid artery, the carotid beat volume (CBV), can be generally expressed as the fraction of the SV distributed to one carotid artery (CAFLOWFRAC). The CBV can also be calculated analogously to the SV, by multiplying the CSA of the carotid artery (CSACA) by the VTICENT-CA. Therefore, we arrive at Eq. (5):
By substituting Eq. (4) (for SV) into Eq. (5) above, and rearranging, we arrive at Eq. (6):
And finally, to convert VTICENT-CA to VTIMAX-CA, which was the measurement obtained by Cheong and colleagues, we derive Eq. (7):
where K = 1.6
3 Clinical implications
To make this more concrete, we might consider plugging in some typical anthropometric values into Eq. (7). For example, if typical CSALVOT [12] and CSACA [13] values are 3.6 cm2 and 0.36 cm2, respectively, then the CSALVOT-to-CSACA ratio is roughly 10. Curiously, a reasonable approximation of the CAFLOWFRAC is 0.10 [14], meaning that the CSALVOT-to-CSACA ratio and CAFLOWFRAC reduce to 1.0. Nevertheless, as detailed above, the maximum velocity in the carotid artery is greater than its centroid; thus, we expect the VTIMAX-CA to be greater than the VTILVOT as a function of the velocity profile (i.e., K = 1.6). One speculative explanation for the very slight overestimation observed by Cheong and colleagues is their novel method of insonating the left carotid artery. They ‘looked down’ from the supraclavicular fossa and may have insonated near the bifurcation of the left common carotid artery from the aortic arch. Velocity profiles at sharp bifurcations behave in complicated ways [2], but the profile can be flat near the origin, especially if the mother vessel is large like the aorta. The profile in the smaller vessel then evolves a parabolic morphology only after a distance known as the ‘entrance length,’ which is estimated as roughly 10 cm for the carotid arteries [2]. Thus, insonating near the origin of the left carotid artery may have reduced K towards a ‘plug’ profile value (i.e., K = 1.1 or 1.2) which would make the VTIMAX-CA closer in absolute value to the VTILVOT.
Regardless of the above, the clinical implications of Eq. (7) are probably greater for something Cheong et al. did not do, that is, perform a hemodynamic intervention. When doing so, the clinician is typically trying to infer change in the VTILVOT via the VTIMAX-CA We see, however, that two variables in particular (i.e., the CSACA, and CAFLOWFRAC) may co-vary during an intervention and thus dissociate the VTIMAX-CA from the VTILVOT.
First, with provision of intravenous fluid, the CSACA can increase [15]. This may be especially important in hypotensive patients in whom increased in mean arterial pressure affects relatively large vessel distension [16]. Per Eq. (7), augmented CSACA causes the VTIMAX-CA to underestimate the VTILVOT.
Second, an intervention that also changes the CAFLOWFRAC would also cause VTIMAX-CA to diverge from the VTILVOT. Fundamentally, the CAFLOWFRAC is directly proportional to the ratio of whole-body-to-head vascular impedance [6]. For example, lowering body-to-head impedance diminishes CAFLOWFRAC. An illustration of this is exercise, where muscles vasodilate and ‘siphon’ blood away from the head. This was shown in the study of Sato and colleagues where baseline CAFLOWFRAC was about 0.14 and fell to about 0.06 at peak exercise [17]. Ostensibly, inodilators have a similar effect; per Eq. (7), when CAFLOWFRAC falls, VTIMAX-CA underestimates VTILVOT. On the other hand, increased body-to-head vascular impedance raises CAFLOWFRAC and causes the VTIMAX-CA to overestimate VTILVOT. Catecholamines, which preferentially vasoconstrict ‘non-essential’ blood flow to maintain brain and coronary perfusion have this effect. This was recently observed by Kim and colleagues where carotid blood flow increased relative to cardiac output in response to norepinephrine [18]. Though catecholamines are the most commonly employed intervention that raises body-to-head impedance, mechanical therapies such as resuscitative endovascular balloon occlusion of the aorta (i.e., REBOA) and intra-aortic counter-pulsation would have similar hemodynamic effects.
Finally, within Eq. (7) we can reasonably assume constancy of the CSALVOT during most interventions, though the value of K, in theory, might decrease with CSACA. This is because the Womersley equation predicts flatter velocity profiles (i.e., decreasing K) with increasing vessel diameter [19]. Thus, carotid artery vessel distention has multiple mechanisms by which VTIMAX-CA underestimates VTILVOT.
In summary, Cheong and colleagues are to be congratulated for their impressive clinical work and their novel approach to carotid insonation. As shown in Eq. 7, there is a direct relationship between VTILVOT and VTIMAX-CA. However, vessel distension, CAFLOWFRAC and velocity profile will mediate this link and these covariates may be especially important during hemodynamic interventions where the clinician performs pre-post VTI calculations. Furthermore, the framework discussed above could be applied to peripheral arteries other than the carotid. Novel means to infer real-time vessel diameter, body-to-head impedance and velocity profile will better model the association between the left ventricle and common carotid artery, especially in conjunction with other Doppler measures such as the corrected flow time [6].
Availability of data and materials
Not applicable.
References
Cheong I, Otero Castro V, Sosa FA, Tort Oribe B, Merlo PM, Tamagnone FM. Carotid flow as a surrogate of the left ventricular stroke volume. J Clin Monit Comput. 2022. https://doi.org/10.1007/s10877-022-00938-7.
Evans DH. On the measurement of the mean velocity of blood flow over the cardiac cycle using Doppler ultrasound. Ultrasound Med Biol. 1985;11:735–41.
Nelson T, Pretorius D. The Doppler signal: where does it come from and what does it mean? Am J Roentgenol. 1988;151:439–47.
Blanco P. Volumetric blood flow measurement using Doppler ultrasound: concerns about the technique. J Ultrasound. 2015;18:201–4.
Gill RW. Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol. 1985;11:625–41.
Kenny J-ÉS, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Yang Z, Eibl AM, Eibl JK, Kim C-H, Johnson BD. Carotid artery velocity time integral and corrected flow time measured by a wearable Doppler ultrasound detect stroke volume rise from simulated hemorrhage to transfusion. BMC Res Notes. 2022;15:7.
Kenny J-ÉS, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Yang Z, Eibl AM, Eibl JK, Kim C-H, Johnson BD. Carotid Doppler ultrasonography correlates with stroke volume in a human model of hypovolaemia and resuscitation: analysis of 48 570 cardiac cycles. Br J Anaesth. 2021;127:e60–3.
Kenny J-ÉS, Munding CE, Eibl JK, Eibl AM, Long BF, Boyes A, Yin J, Verrecchia P, Parrotta M, Gatzke R. A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery. Sci Rep. 2021;11:1–11.
Kenny J-ÉS. Functional hemodynamic monitoring with a wireless ultrasound patch. J Cardiothorac Vasc Anesth. 2021;35:1509–15.
Kenny J-ÉS, Munding CE, Eibl AM, Eibl JK. Wearable ultrasound and provocative hemodynamics: a view of the future. Crit Care. 2022;26:329.
Blanco P. Rationale for using the velocity–time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings. Ultrasound J. 2020;12:1–9.
Leye M, Brochet E, Lepage L, Cueff C, Boutron I, Detaint D, Hyafil F, Iung B, Vahanian A, Messika-Zeitoun D. Size-adjusted left ventricular outflow tract diameter reference values: a safeguard for the evaluation of the severity of aortic stenosis. J Am Soc Echocardiogr. 2009;22:445–51.
Yazici B, Erdogmus B, Tugay A. Cerebral blood flow measurements of the extracranial carotid and vertebral arteries with Doppler ultrasonography in healthy adults. Diagn Interv Radiol. 2005;11:195.
Gassner M, Killu K, Bauman Z, Coba V, Rosso K, Blyden D. Feasibility of common carotid artery point of care ultrasound in cardiac output measurements compared to invasive methods. J Ultrasound. 2015;18:127–33.
Hilbert T, Klaschik S, Ellerkmann RK, Putensen C, Thudium M. Common carotid artery diameter responds to intravenous volume expansion: an ultrasound observation. Springerplus. 2016;5:853.
Hansen F, Mangell P, Sonesson B, Länne T. Diameter and compliance in the human common carotid artery—variations with age and sex. Ultrasound Med Biol. 1995;21:1–9.
Sato K, Ogoh S, Hirasawa A, Oue A, Sadamoto T. The distribution of blood flow in the carotid and vertebral arteries during dynamic exercise in humans. J Physiol. 2011;589:2847–56.
Kim SG, Jo IJ, Kang SY, Yoo J, Lee G, Park JE, Kim T, Hwang SY, Cha WC, Shin TG, Han H, Yoon H. The effect of norepinephrine on common carotid artery blood flow in septic shock patients. Sci Rep. 2021;11:16763.
Womersley J. The mathematical analysis of the arterial circulation in a state of oscillatory motion. 1957; Wright Air Development Center Technical Report WADC-TR-56-614
Funding
Not applicable.
Author information
Authors and Affiliations
Contributions
JESK is entirely responsible for the entirety of this submission.
Corresponding author
Ethics declarations
Competing interests
Dr. Kenny is the co-founder and chief medical officer of Flosonics Medical, a wearable point of care ultrasound company in Toronto, Canada.
Ethical approval
Not applicable.
Consent to participate
Not applicable.
Consent for publication
Not applicable.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kenny, JE.S. A theoretical foundation for relating the velocity time integrals of the left ventricular outflow tract and common carotid artery. J Clin Monit Comput 37, 937–939 (2023). https://doi.org/10.1007/s10877-022-00969-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10877-022-00969-0