Abstract
There is an accepted clinical requirement for a luting cement that can be command set upon satisfactory placement of an orthodontic appliance onto dentition. This work evaluates the suitability of ultrasound, imparted from a dental scaler, as a potential mechanism for achieving this. The net setting times and subsequent compressive strengths of a range of commercial and experimental glass polyalkenoate cements (GPCs) were evaluated, using modified ISO 9917 methods, when set both chemically and by ultrasound. The ultrasound was applied to the GPC through an orthodontic brace. It was possible to command set GPCs by the application of five to ten seconds of ultrasound; the exact time required being dependent upon the composition of the GPC in question. The compressive strengths of these cements can be improved by around 90% with the command set when the optimum PAA molecular weight and tartaric acid content is employed.
Similar content being viewed by others
References
B. E. KENT and A. D. WILSON, Br. Dent. J. 135 (1973) 322.
S. CRISP and A. D. WILSON, J. Dent. Res. 53 (1974) 1408.
R. J. G. DE MOOR and R. M. H. VERBEECK, Biomaterials. 19 (1998) 2269.
S. B. MITRA J Dent Res; 70 (1991) 72–74.
S. B. MITRA, European Patent Application. No. 0323 120 A2; (1989).
P. SASANALUCKET, K. R. ALBUSTANY, P. J. DOHERTY and D. F. WILLIAMS, Biomaterials, 14 (1993) 906–916.
J. W. NICHOLSON and H. M. ANSTICE, J. Mater. Sci.: Mater Med. 3 (1992) 447.
W. KANCHANAVASITA, H. M. ANSTICE and G. J. PEARSON, J. Dent. 26/8 (1998) 707–712.
M. A. CATTANI-LORENTE, V. DUPUIS, J. PAYAN, F. MOYA, and J. M. MEYER, Dental Materials 15/1 (1999) 71.
S. CRISP and A. D. WILSON, J. Dent. Res. 55 (1976) 1023–1031.
A. D. WILSON, S. CRISP, and A. J. FERNER, J. Dent. Res. 55 (1976) 489–495.
H. J. PROSSER, S. M. JEROME and A. D. WILSON, J. Dent. Res. 61 (1982) 1195–1198.
S. CRISP, B. G. LEWIS and A. D. WILSON, J. Dent. 4 (1976) 162–166.
R. G. HILL, C. P. WARRENS and A. D. WILSON, J. Mater. Sci. 24 (1989) 363.
R. G. HILL and S. A. LABOK, J. Mater. Sci. 27 (1992) 67.
R. G. HILL, J. Mater. Sci. 28 (1993) 3851–3858.
K. S. SUSLICK and G. J. PRICE, Annu. Rev. Mater. Sci. 29 (1999) 295–326.
S. J. DOKTYCZ and K. S. SUSLICK, Science, 247 (1990) 1067–1069.
M. R. TOWLER, A. J. BUSHBY, R. W. BILLINGTON and R. G. HILL, Biomaterials, 22/11 (2001) 1401–1406.
M. R. TOWLER, C. M. CROWLEY and R. G. HILL, J. Mat. Sci.: Letters. 22/7 (2003) 539–541.
E. TWOMEY, M. R. TOWLER, C. M. CROWLEY, J. DOYLE and S. HAMPSHIRE; J. Mat. Sci. 39/14 (2004) 4631–4632.
S. C. LEA, G. J. PRICE and A. D. WALMSLEY, Ultrasonics Sonochemistry. In Press (2003).
C. J. KLEVERLAAN, RNB V. A. N DUINEN and A. J. FEILZER, Dent. Mat. 20 (2004) 45–50.
G. L. GOOBERMAN, ‘Ultrasonics: Theory and Application’, English University Press, (1968).
ISO 9917(E) International Standard. (1991) 1–13.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tanner, D.A., Rushe, N. & Towler, M.R. Ultrasonically set glass polyalkenoate cements for orthodontic applications. J Mater Sci: Mater Med 17, 313–318 (2006). https://doi.org/10.1007/s10856-006-8229-7
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10856-006-8229-7