Abstract
Amperometric enzyme immunosensors based on planar electrodes were developed for the rapid determination of some bacterial antigens. Conditions for the operation of analytical devices (matrix component, pH of the buffer solution, and the dilution of antibodies in the biosensing part of the sensor) were selected. The analytical characteristics of enzyme immunosensors (analytical ranges and determination limits) were estimated. The analytical devices were tested in determining pyogenic streptococcus and aurous staphylococcus antigens in the blood serum of patients suffering from infectious diseases. It was shown that the developed sensors can be used for diagnosing diseases caused by these microorganisms.
Similar content being viewed by others
REFERENCES
Balaban, N., Goldkorn, T., Nhan, R.T., et al., Science, 1998, vol. 280, no.5362, p. 438.
Beletskaya, L.V., Verbolovich, P.A., and Polosukhina, T.Ya., Eksperimental’naya streptokokkovaya infektsiya (Experimental Streptococcal Infection), Alma-Ata: Nauka, 1978.
Swaminathan, B. and Feng, P., Annu. Rev. Microbiol., 1994, vol. 48, p. 401.
Vel’tishchev, Yu.E., Komarov, F.I., Navashin, S.M., et al., Spravochnik prakticheskogo vracha (Reference Book of a Medical Practitioner), Moscow: Meditsina, 1992.
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., and Wilkins, E., Biosens. Bioelectron., 1999, vol. 14, p. 599.
Meditsinskaya mikrobiologiya (Medical Microbiology), Pokrovskii, V.I. and Poddeev, O.K., Eds., Moscow: Geotar Meditsina, 1200.
Macaluso, L. and Lapeyre, C., Analysis, 2000, vol. 28, no.7, p. 610.
Lam, M.T., Boulet, C.A., and Le, X.C., Anal. Chim. Acta, 2002, vol. 457, no.1, p. 21.
Kientz, C.E., Hulst, A.G., and Wils, E.R.J., J. Chromatogr., 1997, vol. 757, nos. 1–2, p. 51.
Watts, H.J., Lowe, C.R., and Pollard-Knight, D.V., Anal. Chem., 1994, vol. 66, p. 2465.
Bao, L., Deng, L., Nie, L., et al., Anal. Chim. Acta, 1996, vol. 319, p. 97.
Rishpon, J. and Ivnitski, D., Biosens. Bioelectron., 1997, vol. 12, no.3, p. 195.
Bao, L.L., Tan, H.W., Duan, Q., et al., Anal. Chim. Acta, 1998, vol. 369, nos. 1–2, p. 139.
Brooks, J.L., Mirhabibollahi, B., and Kroll, R.G., J.Appl. Bacteriol., 1992, vol. 73, p. 189.
Complementary Immunoassays, Collins, W.P., Ed., New York: Wiley, 1988. Translated under the title Novye metody immunoanaliza, Moscow: Mir, 1991.
Medyantseva, E.P., Safina, G.R., Khaldeeva, E.V., et al., Zh. Anal. Khim., 2004, vol. 59, no.2, p. 190 [J. Anal. Chem. (Engl. Transl.), vol. 59, no. 2, p. 168].
Plambeck, J., Electroanalytical Chemistry: Basic Principles and Applications, New York: Wiley, 1982. Translated under the title Elektrokhimicheskie metody analiza: Osnovy teorii i primenenie, Moscow: Mir, 1985.
Lehninger, A., Principles of Biochemistry, New York: Worth, 1982. Translated under the title Osnovy biokhimii, Moscow: Mir, 1985, vol. 1.
Berezin, I.V., Klyachko, N.L., Levashov, A.V., et al., Immobilizovannye fermenty (Immobilized Enzymes), Moscow: Vysshaya Shkola, 1987.
Author information
Authors and Affiliations
Additional information
__________
Translated from Zhurnal Analiticheskoi Khimii, Vol. 60, No. 6, 2005, pp. 616–623.
Original Russian Text Copyright © 2005 by Safina, Medyantseva, Fomina, Glushko, Budnikov.
Rights and permissions
About this article
Cite this article
Safina, G.R., Medyantseva, E.P., Fomina, O.G. et al. Amperometric Enzyme Immunosensors for Diagnosing Certain Infectious Diseases. J Anal Chem 60, 546–552 (2005). https://doi.org/10.1007/s10809-005-0137-3
Received:
Issue Date:
DOI: https://doi.org/10.1007/s10809-005-0137-3