Skip to main content
Log in

Traveling Wave-Based Fault Location System Connected to Busbar Voltage Transformers

  • POWER SYSTEMS AND ELECTRIC NETWORKS
  • Published:
Power Technology and Engineering Aims and scope

This article discusses the development stages of a traveling wave-based fault location (FL) system on electricity transmission lines that monitors voltage signals only. This article also presents a 330 kV power network model with integrated FL equipment and the simulation results of transient processes caused by short failures in this network. A traveling wave-based FL algorithm that uses a statistical method to determine the time of traveling wave arrival at the place of FL system installation is developed. The factors that affect the accuracy of wave-based FL based on signals from capacitive voltage transformers are analyzed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. M. Shalyt, Determination of Fault Location in Electrical Networks [in Russian], Énergoizdat, Moscow (1982).

  2. L. J. Lewis, “Traveling wave relations applicable to power-system fault locators,” AIEE Trans., 50, 1671 – 1680 (1951).

    Google Scholar 

  3. T. W. Stringfield, “Fault location for overhead lines,” AIEE Trans., August, 518 – 526 (1957).

  4. M. A. Street, “Delivery and application of precise timing for a traveling wave fault detector system,” in: Proc. of the 22nd Annual Precise Time and Time Interval Applications and Planning Meeting, NASA Publication 3116, pp. 355 – 359 (1991).

  5. M. A. Street, I. P. Thurein, and K. E. Martin “Global positioning system applications at the Bonneville Power Administration,” in: Proc. of the IEEE Northcon/95, Portland, Oregon, October 1995, pp. 244 – 251 (1995).

  6. M. Kezunovic, L. Kojovic, V. Skendzic, C. W. Fromen, D. Sevcik, and S. L. Nilsson, “Digital models of coupling capacitor voltage transformers for protective relay studies,” IEEE Trans. Power Deliv., 7(4), 1927 – 1935 (1992).

    Article  Google Scholar 

  7. J. R. Lucas, P. G. McLaren, W. W. L. Keerthipala, and R. P. Jawinghe, “Improved simulation models for current and voltage transformers in relay studies,” in: IEEE PES 1991 Summer Meeting, San Diego, California, July 1991, Paper 91SM 317, 8 PWRD.

  8. H. Lee, A. M. Mousa, “GPS traveling wave fault locator systems: investigation into the anomalous measurements related to lightning strikes,” IEEE Trans. Power Deliv., 11(3), 1214 – 1223 (1996).

    Article  Google Scholar 

  9. M. A. Redfern, S. C. Terry, F. V. P. Robinson, and Z. Q. Bo, “A Laboratory investigation into the use of MV current transformers for transient based protection,” in: Int. Conf. on Power Systems Transients (IPST 2003), New Orleans, LA, USA (2003).

  10. F. S. Carvalho, S. J. Carneiro, “Transient conditions in CCVTs outputs and their effects on the detection of traveling waves,” Electr. Pow. Sys. Res., 76, 616 – 625 (2006).

    Article  Google Scholar 

  11. S. Zhao, H. Y. Li, F Ghassemi., and P. Crossley, “Impact of power quality sensor technique on power system protection voltage transient measurements,” in: 10th IET Int. Conf. on Developments in Power System Protection (2010).

  12. A. S. Butymov, A. S. Gaivoronsky, and A. V. Purtov, “System for monitoring lightning discharges and determining the locations of damage to overhead lines,” Énerg. Edinoi Seti, No. 4, 44 – 45 (2012).

  13. S. V. Krasnyshov, M. I. Manzheliy, V. F. Lachugin, S. V. Sidoruk, V. A. Dzhangirov, and I. E. Boyarkin, “Experience of using recorders of synchronized measurements of currents and voltages on 110 kV OHL,” Élektr. Stantsii, No. 9, 42 – 47 (2010).

  14. V. F. Lachugin, D. I. Panfilov, A. N. Smirnov, and P. S. Platonov, “Determination of fault location for high voltage overhead lines using satellite communications. Travelling wave-based method of bilateral synchronized measurements,” Énerg. Edinoi Seti, No. 2(31), 30 – 41 (2017).

  15. STO 56947007-33.060.40.125–2012. General Technical Requirements for Devices for Processing and Connecting HF Communication Channels according to 35 – 750 kV OHL [in Russian].

  16. G. V. Mikutskiy, Devices for Processing and Connecting High-Frequency Channels [in Russian], Énergiya, Moscow (1974).

  17. V. F. Lachugin, D. I. Panfilov, A. N. Smirnov, S. A. Obraztsov, A. A. Ryvkin, and A. O. Shimina, “Multifunctional device for registering processes, monitoring the quality of electricity, and determining the fault location on power lines,” Élektr. Stantsii, No. 8, 29 – 36 (2013).

  18. V. F. Lachugin, D. I. Panfilov, and A. N. Smirnov, “Implementation of the wave-based method for determining the fault location on power lines using statistical methods of data analysis,” Izv. RAN. Énergiya, No. 6, 137 – 146 (2013).

  19. I. N. Popov, V. F. Lachugin, and G. V. Sokolova, Relay Protection Based on the Control of Transient Processes [in Russian], Énergoatomizdat, Moscow (1986).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. F. Lachugin.

Additional information

Translated from Élektricheskie Stantsii, No. 1, January 2021, pp. 21 – 30. DOI: 10.34831/EP.2021.1074.1.003

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lachugin, V.F., Platonov, P.S., Alekseev, V.G. et al. Traveling Wave-Based Fault Location System Connected to Busbar Voltage Transformers. Power Technol Eng 55, 282–290 (2021). https://doi.org/10.1007/s10749-021-01353-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-021-01353-9

Keywords

Navigation