The current status of Russian boilers for power generating units with supercritical steam pressure is discussed. It is noted that the equipment in almost all the 300 and 500 MW coal-fired generator units, in particular their boilers, have been running for more than 200 thousand hours and have low efficiencies and environmental performance, so that these units should be replaced. Gas-oil power generating units should be replaced because their energy efficiency is low compared to combined cycle (steam-gas) units. The major ways of creating competitive domestic boilers for advanced power generating units with supercritical steam parameters are pointed out.
Similar content being viewed by others
References
Yu. S. Khodakov, L. M. Eremin, and A. A. Alfeev, “The current state of research on denitrification of smokestack gases at thermal power plants,” Izv. RAN. Énergetika, No. 5 (1997).
A. M. Zykov, S. N. Anichkov, O. N. Bragina, A. M. Tikhomirov, O. N. Kulish, S. A. Kuzhevatov, I. Sh. Glezer, and S. F. Torkhunov, “Experience with the introduction of an SNCR system in the 330 MW power generating unit at the Kashira GRÉS power plant,” Élektr. Stantsii, No. 6 (2012).
A. Sh. Leizerovich, G. D. Avrutskii, I. A. Savenkova, and M. V. Lazarev, “Modern pulverized-coal steam-turbine power generating units with supercritical pressure,” Énergokhoz. Rubezhom, No. 5 (2009).
Author information
Authors and Affiliations
Additional information
Translated from Élektricheskie Stantsii, No. 1, January 2014, pp. 9 – 13.
1 This work was supported by the Ministry of Education and Science of the Russian Federation, contract No. 14.516.12.0001, “Theoretical and experimental studies for the development of thermal configurations and boilers for hybrid power generation systems” of March 13, 2013.
Rights and permissions
About this article
Cite this article
Tugov, A.N., Shvarts, A.L. & Kotler, V.R. Domestic Boilers with Supercritical Steam Pressure: Status and Prospects1 . Power Technol Eng 48, 123–127 (2014). https://doi.org/10.1007/s10749-014-0495-9
Published:
Issue Date: