Managing Inverted Arch Heaving in Sanlian Tunnel: Analysis of Inverted Arch Structure Utilizing Prestressed Anchor Rods

  • Original Paper
  • Published:
Geotechnical and Geological Engineering Aims and scope Submit manuscript

Abstract

The inverted arch heaving is detrimental to the structural safety of tunnels and can cause operational accidents. It is necessary to perform the research on maintenance strategies of inverted arch heaving to ensure the structural safety of tunnels. This paper took the Sanlian Tunnel in Southwest China as the engineering background, and the goals of this research were to explore the cause and maintenance of the inverted arch heaving in tuff stratum. The research methodology in this paper includes numerical simulation and field observations. Proposing maintenance measures for inverted arch heaving in tuff formation and grasping the long-term stress characteristics of the inverted arch structure are the contributions of this study. The inverted arch distress includes heaving (85 mm), cracks, and flexural deformation of reinforcements. FLAC3D numerical simulation shows that the continuous deformation because of the tuff rheological effect has an adverse impact on the inverted arch structure, resulting in cracking and heaving. Deepened inverted arch structure by 65 cm combined with 8 m-long prestressed anchor rods were adopted to control the distress. The effectiveness of the maintenance approach was assessed through field observations lasting for three years. Influenced by the long-term rheology of the tuff, the stresses in the inverted arch increased rapidly at first, then slowly, and gradually stabilized two years after the construction was completed. The maximum stress of prestressed anchor rods, steel arch frames, initial support concrete, and secondary lining concrete were 84.53 MPa, 22.40 MPa, 13.35 MPa, 7.20MP, respectively, which were less than the allowable stress (namely 210 MPa, 160 MPa, 23.8 MPa, 32.5 MPa, respectively). Furthermore, the minimum safety factor (namely 6.75) of the reinforced inverted arch met the requirements (>2.4) specified by the Code for Design of Railway Tunnel. The reported findings validate the overall safety of the inverted arch structure following the implementation of control measures, demonstrating the efficacy of these measures in effectively addressing the identified issues. The proposed maintenance strategies and revealed long-term stress characteristics of inverted arch structure in this work can be referenced for construction of tunnels in tuff formation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig.1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25

Similar content being viewed by others

Data availability

Enquiries about data availability should be directed to the authors. The collected data is available upon request.

References

Download references

Acknowledgements

The authors would like to acknowledge the support of this research by Sanlian Tunnel Project Department of Chinese Railway Tunnel Group Limited.

Funding

This work was funded by the National Natural Science Foundation of China under Grant No. 52302020.

Author information

Authors and Affiliations

Authors

Contributions

YW: Conceptualization, methodology, software, validation, investigation, data curation, formal analysis, funding acquisition, writing-original draft preparation, project administration and revision. HM: writing-review and editing, conceptualization (goals and aims). TKD: writing-review and editing. JG: funding acquisition.

Corresponding author

Correspondence to Thevaneyan Krishta David.

Ethics declarations

Declarations

YW and JG report financial support was provided by National Natural Science Foundation of China under Grant No. 52302020. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Conflict of interest

The authors have no relevant financial or non-financial interests to disclose.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, Y., Krishta David, T., Mansor, H. et al. Managing Inverted Arch Heaving in Sanlian Tunnel: Analysis of Inverted Arch Structure Utilizing Prestressed Anchor Rods. Geotech Geol Eng (2024). https://doi.org/10.1007/s10706-024-02792-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10706-024-02792-7

Keywords

Navigation