Abstract
The main goal of this large-scale pilot distribution study was to systematically investigate the impacts of blending different source waters on distribution water qualities. The principal source waters investigated were conventionally treated ground water (G1), surface water processed by enhanced treatment (S1), and desalted seawater by reverse osmosis membranes (RO). Due to the nature of raw water quality and associated treatment processes, G1 water had high alkalinity, while S1 and RO sources were characterized as high sulfate and high chloride waters, respectively. One year of pilot pipe study demonstrated that water quality was significantly deteriorated by increased color when source water blends with characteristics different from historic groundwater were introduced to pipe distribution systems. Elevated color was associated with release of iron corrosion products, mainly from aged unlined cast iron pipes. Iron release increased significantly when exposed to RO and S1 waters: that is, the greater iron release was experienced with alkalinity reduced below the background of G1 water. Lead and copper release to water, on the other hand, enhanced with the application of RO and G1 waters, respectively.
Similar content being viewed by others
References
AWWA Research Foundation and DVGW-Technologiezentrum Wasser: 1996, Internal Corrosion of Water Distribution Systems (Second Edition).
Boffardi, B. P.: 1995, ‘Lead corrosion’, J. NEWWA 109, 121.
Dietz, J. D., Taylor, J. S., Mulford, L. A., Cullen, C. J. and Owen, C. A.: 2002, ‘Assessment of source water blends on distribution system water quality’, Proceeding of Water Quality Technology Conference, American Water Works Association.
Edwards, M., Schock, M. R. and Meyer, T. E.: 1996, ‘Alkalinity, pH, and copper corrosion by-product release’, J. AWWA 81.
Hem, L. J., ViK, E. A. and Bjornson-Langen, A.: 2001, ‘Water treatment to reduce internal corrosion in drinking water distribution system in Oslo’, Water Sci. Technol. Water Supply 1, 9.
Lin, J., Ellaway, M. and Adrien, R.: 2001, ‘Study of corrosion material accumulated on the inner wall of steel water pipe’, Corrosion Sci. 43, 2065.
McNeill, L. S. and Edwards, M.: 2001, ‘Iron pipe corrosion in distribution systems’, J. AWWA 93, 88.
Pehkonen, S. O., Palit, A. and Zhang, X.: 2001, ‘Effect of specific water quality parameters on copper corrosion’, Corrosion 58(2), 156.
Price, S. and Jefferson, T. F.: 1997, ‘Corrosion control strategies for changing water supplies in Tucson, Arizona’, J. NEWWA 111, 285.
Sarin, P., Snoeyink, V. L., Bebee, J., Kriven, W. M. and Clement, J. A.: 2001, ‘Physico-chemical characteristics of corrosion scales in old iron pipes’, Water Res. 35, 2961.
Schock, M. R.: 1989, ‘Understanding corrosion control strategies for lead’, J. AWWA 81(7), 88.
Song, L., Hong, S., Ong, S. L., Ng, W. J. and Hu, J. Y.: 2002, ‘Simulations of a full scale reverse osmosis desalination process’, ASCE J. Environ. Eng. October, 960–966.
Wang, Z., Moore, R. C., Felmy, A. R., Mason, M. J. and Kukkadapu, R. K.: 2001, ‘A study of the corrosion products of mild steel in high ionic strength brines’, Waste Manage. 21, 335.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Taylor, J., Tang, Z., Xiao, W. et al. Monitoring of Distribution Water Qualities Under Various Source Water Blending. Environ Monit Assess 117, 59–71 (2006). https://doi.org/10.1007/s10661-006-7672-8
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10661-006-7672-8