Abstract

Background

Bispectral index (BIS ) monitoring has been used as an objective measurement tool for sedation depth and has been proposed as a guidance to reduce the risk of intraprocedural over-sedation. However, the results of several studies evaluating the benefits of BIS monitoring for gastrointestinal endoscopy were not consistent.

Aims

This meta-analysis aimed to assess the reduction in total consumption of administrated propofol and recovery time under BIS during gastrointestinal endoscopy.

Methods

Electronic databases (MEDLINE, EMBASE, WEB of SCIENCE, and the Cochrane Central Register of Controlled Trials) were searched for articles published through March 2015. After screening, the reviewers extracted information on 11 randomized controlled trials. A total of 1039 patients (526 in BIS and 513 in non-BIS group) were included in this study.

Results

Meta-analyses showed that the total propofol consumption (the pooled standardized mean difference [SMD]: −0.15, 95 % confidence interval [CI]: −0.28 to −0.01) was significantly lower in the BIS group than in the non-BIS group, although mean propofol consumption was not significantly different. Recovery time (the pooled SMD: −0.04 [95 % CI −0.46 to 0.38, P = 0.85]), procedure time (the pooled SMD: 0.13 [95 % CI −0.03 to 0.29, P = 0.11]), adverse events, and satisfaction-related outcomes were not significantly superior in the BIS group when compared with the non-BIS group.

Conclusions

This first meta-analysis showed that BIS monitoring appears to be an effective and safe method for avoiding unnecessary administration of propofol and for providing adequate sedation during endoscopic procedures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. Glass PS, Bloom M, Kearse L, Rosow C, Sebel P, Manberg P. Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. Anesthesiology. 1997;86:836–847.

    Article  CAS  PubMed  Google Scholar 

  2. Yang KS, Habib AS, Lu M, et al. A prospective evaluation of the incidence of adverse events in nurse-administered moderate sedation guided by sedation scores or Bispectral Index. Anesth Analg. 2014;119:43–48.

    Article  CAS  PubMed  Google Scholar 

  3. Kertai MD, Whitlock EL, Avidan MS. Brain monitoring with electroencephalography and the electroencephalogram-derived bispectral index during cardiac surgery. Anesth Analg. 2012;114:533–546.

    Article  PubMed Central  PubMed  Google Scholar 

  4. Liu SS. Effects of Bispectral Index monitoring on ambulatory anesthesia: a meta-analysis of randomized controlled trials and a cost analysis. Anesthesiology. 2004;101:311–315.

    Article  PubMed  Google Scholar 

  5. Punjasawadwong Y, Boonjeungmonkol N, Phongchiewboon A. Bispectral index for improving anaesthetic delivery and postoperative recovery. Cochrane Datab Syst Rev. 2007:CD003843.

  6. Chen SC, Rex DK. An initial investigation of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy. Am J Gastroenterol. 2004;99:1081–1086.

    Article  PubMed  Google Scholar 

  7. Billard V, Gambus PL, Chamoun N, Stanski DR, Shafer SL. A comparison of spectral edge, delta power, and bispectral index as EEG measures of alfentanil, propofol, and midazolam drug effect. Clin Pharmacol Ther. 1997;61:45–58.

    Article  CAS  PubMed  Google Scholar 

  8. Bower AL, Ripepi A, Dilger J, Boparai N, Brody FJ, Ponsky JL. Bispectral index monitoring of sedation during endoscopy. Gastrointest Endosc. 2000;52:192–196.

    Article  CAS  PubMed  Google Scholar 

  9. Yu YH, Han DS, Kim HS, et al. Efficacy of bispectral index monitoring during balanced propofol sedation for colonoscopy: a prospective, randomized controlled trial. Dig Dis Sci. 2013;58:3576–3583.

    Article  CAS  PubMed  Google Scholar 

  10. von Delius S, Salletmaier H, Meining A, et al. Bispectral index monitoring of midazolam and propofol sedation during endoscopic retrograde cholangiopancreatography: a randomized clinical trial (the EndoBIS study). Endoscopy. 2012;44:258–264.

    Article  Google Scholar 

  11. Jang SY, Park HG, Jung MK, et al. Bispectral index monitoring as an adjunct to nurse-administered combined sedation during endoscopic retrograde cholangiopancreatography. World J Gastroenterol. 2012;18:6284–6289.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  12. Paspatis GA, Chainaki I, Manolaraki MM, et al. Efficacy of bispectral index monitoring as an adjunct to propofol deep sedation for ERCP: a randomized controlled trial. Endoscopy. 2009;41:1046–1051.

    Article  CAS  PubMed  Google Scholar 

  13. Park WY, Shin YS, Lee SK, Kim SY, Lee TK, Choi YS. Bispectral index monitoring during anesthesiologist-directed propofol and remifentanil sedation for endoscopic submucosal dissection: a prospective randomized controlled trial. Yonsei Med J. 2014;55:1421–1429.

    Article  PubMed Central  PubMed  Google Scholar 

  14. Al-Sammak Z, Al-Falaki MM, Gamal HM. Predictor of sedation during endoscopic retrograde cholangiopancreatography–bispectral index vs clinical assessment. Middle East J Anaesthesiol. 2005;18:141–148.

    CAS  PubMed  Google Scholar 

  15. Drake LM, Chen SC, Rex DK. Efficacy of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy: a randomized controlled trial. Am J Gastroenterol. 2006;101:2003–2007.

    Article  PubMed  Google Scholar 

  16. Imagawa A, Fujiki S, Kawahara Y, et al. Satisfaction with bispectral index monitoring of propofol-mediated sedation during endoscopic submucosal dissection: a prospective, randomized study. Endoscopy. 2008;40:905–909.

    Article  CAS  PubMed  Google Scholar 

  17. Kang KJ, Min BH, Lee MJ, et al. Efficacy of bispectral index monitoring for midazolam and meperidine induced sedation during endoscopic submucosal dissection: a prospective, randomized controlled study. Gut Liver. 2011;5:160–164.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  18. DeWitt JM. Bispectral index monitoring for nurse-administered propofol sedation during upper endoscopic ultrasound: a prospective, randomized controlled trial. Dig Dis Sci. 2008;53:2739–2745.

    Article  PubMed  Google Scholar 

  19. Lehmann A, Boldt J, Thaler E, Piper S, Weisse U. Bispectral index in patients with target-controlled or manually-controlled infusion of propofol. Anesth Analg. 2002;95:639–644.

    PubMed  Google Scholar 

  20. Qadeer MA, Vargo JJ, Patel S, et al. Bispectral index monitoring of conscious sedation with the combination of meperidine and midazolam during endoscopy. Clin Gastroenterol Hepatol Off Clin Pract J Am Gastroenterol Assoc. 2008;6:102–108.

    Google Scholar 

  21. Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol. 2009;62:1006–1012.

    Article  PubMed  Google Scholar 

  22. Jadad AR, Moore RA, Carroll D, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17:1–12.

    Article  CAS  PubMed  Google Scholar 

  23. Drummond JC. Monitoring depth of anesthesia: with emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall. Anesthesiology. 2000;93:876–882.

    Article  CAS  PubMed  Google Scholar 

  24. Powers KS, Nazarian EB, Tapyrik SA, et al. Bispectral index as a guide for titration of propofol during procedural sedation among children. Pediatrics. 2005;115:1666–1674.

    Article  PubMed  Google Scholar 

  25. Recart A, Gasanova I, White PF, et al. The effect of cerebral monitoring on recovery after general anesthesia: a comparison of the auditory evoked potential and bispectral index devices with standard clinical practice. Anesth Analg. 2003;97:1667–1674.

    Article  PubMed  Google Scholar 

  26. Health Quality O. Bispectral index monitor: an evidence-based analysis. Ontario Health Technol Assess Ser. 2004;4:1–70.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hyuk Lee.

Ethics declarations

Conflict of interest

All authors have no conflicts of interest or financial ties to disclose. Furthermore, this report is a meta-analysis. The author states that the report includes every item in the PRISMA checklist for meta-analysis clinical studies. Also, this manuscript was screened for plagiarism using Turnitin (www.turnitin.com).

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Park, S.W., Lee, H. & Ahn, H. Bispectral Index Versus Standard Monitoring in Sedation for Endoscopic Procedures: A Systematic Review and Meta-Analysis. Dig Dis Sci 61, 814–824 (2016). https://doi.org/10.1007/s10620-015-3945-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10620-015-3945-9

Keywords

Navigation