Skip to main content
Log in

Distinction of non-ischemia inducing versus ischemia inducing coronary stenosis by fluorescent cardiac imaging

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Intraoperative fluorescent cardiac imaging (FCI) can quantitatively assess myocardial perfusion abnormalities produced by graded flow-limiting coronary stenosis (FLS), but there are no data to distinguish FLS from non flow-limiting stenosis (NFLS) to determine their functional significance. The aim of the study was to evaluate whether non-ischemia inducing NFLS can be quantified and differentiated from FLS by FCI technology. Data are compared to gold standard fluorescent microspheres (FM). 11 domestic pigs of either sex underwent sternotomy. Left anterior descending coronary artery blood-flow was recorded by transit-time flow measurements. After baseline and Adenosine-induced hyperemia, two stenosis of low severity (50 and 90 % NFLS) were produced, followed by FLS (50 %) and total vessel occlusion. Time-dependent fluorescence intensity curves were recorded by FCI. Slope of fluorescence intensity (SFI) and background-subtracted peak fluorescence (BSFI) intensity were calculated and data compared to myocardial blood flow measurements using FM. All NFLS and FLS reduced myocardial perfusion as quantified by FCI showing decreased normalized BSFI and SFI (P < 0.001). Box-plot analysis showed significant difference between NFLS (50 and 90 %) and FLS (50 %) assessed by BSFI (P < 0.001) and SFI (P < 0.001). In each animal, a linear correlation between FM-derived myocardial blood flow and FCI-derived BSFI (r = 0.936, P < 0.001) or SFI (r = 0.942, P < 0.001) was observed during baseline, hyperemia, graded NFLS, and FLS. Both, BSFI (r = 0.789, P < 0.001) and SFI (r = 0.802, P < 0.001) significantly correlated with transit-time flow measurements. FCI quantitative technology is capable of distinguishing between non-ischemia inducing NFLS and ischemia inducing FLS showing a good correlation compared to fluorescent microspheres.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Ferguson TB Jr, Chen C, Babb JD, Efird JT, Daggubati R, Cahill JM (2013) Fractional flow reserve-guided coronary artery bypass grafting: Can intraoperative physiologic imaging guide decision making? J Thorac Cardiovasc Surg 146:824–835

    Article  PubMed  Google Scholar 

  2. Hoole SP, Seddon MD, Poulter RS, Starovoytov A, Wood DA, Saw J (2012) Development and validation of the fractional flow reserve (FFR) angiographic scoring tool (FAST) to improve the angiographic grading and selection of intermediate lesions that require FFR assessment. Coron Artery Dis 23:45–50

    Article  PubMed  Google Scholar 

  3. Pijls NH, Van Gelder B, Van der Voort P, Peels K, Bracke FA, Bonnier HJ et al (1995) Fractional flow reserve. A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow. Circulation 92:3183–3193

    Article  CAS  PubMed  Google Scholar 

  4. Pijls NH, De Bruyne B, Peels K, Van Der Voort PH, Bonnier HJ, Bartunek J, Koolen JJ (1996) Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses. N Engl J Med 334:1703–1708

    Article  CAS  PubMed  Google Scholar 

  5. Pijls NH, Fearon WF, Tonino PA, Siebert U, Ikeno F, Bornschein B et al (2010) Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME study. JACC 56:177–184

    Article  PubMed  Google Scholar 

  6. Tonino PA, Fearon WF, De Bruyne B, Oldroyd KG, Leesar MA, Ver Lee PN et al (2010) Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation. J Am Coll Cardiol 55:2816–2821

    Article  PubMed  Google Scholar 

  7. Detter C, Russ D, Iffland A, Wipper S, Schurr MO, Reichenspurner H et al (2002) Near-infrared fluorescence coronary angiography: a new noninvasive technology for intraoperative graft patency control. Heart Surg Forum 5:364–369

    PubMed  Google Scholar 

  8. Russ D, Detter C, Iffland A, Wipper S, Schurr MO, Sailer R et al (2002) Imaging of perfusion with indocyanine green fluorescence—a promising approach. Med Laser Appl 17:31–36

    Article  Google Scholar 

  9. Detter C, Wipper S, Russ D, Iffland A, Burdorf L, Thein E et al (2007) Fluorescent cardiac imaging: a novel intraoperative method for quantitative assessment of myocardial perfusion during graded coronary artery stenosis. Circulation 116:1007–1014

    Article  PubMed  Google Scholar 

  10. Balacumaraswami L (2007) Taggart DP Intraoperative imaging techniques to assess coronary artery bypass graft patency. Ann Thorac Surg 83:2251–2257

    Article  PubMed  Google Scholar 

  11. Kogon B, Fernandez J, Kanter K, Kirshbom P, Vincent B, Maher K et al (2009) The role of intraoperative indocyanine green fluorescence angiography in pediatric cardiac surgery. Ann Thorac Surg 88:632–636

    Article  PubMed  Google Scholar 

  12. Taggart DP, Choudhary B, Anastasiadis K, Abu-Omar Y, Balacumaraswami L, Pigott DW (2003) Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization. Ann Thorac Surg 75:870–873

    Article  PubMed  Google Scholar 

  13. De Bruyne B, Pijls NH, Kalesan B, Barbato E, Tonino PA, Piroth Z et al (2012) Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease. N Engl J Med 367:991–1001

    Article  PubMed  Google Scholar 

  14. Hope-Ross M, Yannuzzi LA, Gragoudas ES, Guyer DR, Slakter JS, Sorenson JA et al (1994) Adverse reactions due to indocyanine green. Ophthalmology 101:529–533

    Article  CAS  PubMed  Google Scholar 

  15. Cherrick GR, Stein SW, Leevy CM, Davidson CS (1960) Indocyanine green: observations on its physical properties, plasma decay, and hepatic extraction. J Clin Invest. 39:592–600

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  16. Kern MJ, Lerman A, Bech JW, De Bruyne B, Eeckhout E, Fearon WF et al (2006) Physiological assessment of coronary artery disease in the cardiac catheterization laboratory: a scientific statement from the American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization. Council on Clinical Cardiology. Circulation. 19(114):1321–1341

    Google Scholar 

  17. Takarada S, Zhang Z, Molloi S (2013) An angiographic technique for coronary fractional flow reserve measurement: in vivo validation. Int J Cardiovasc Imaging 29:535–544

    Article  PubMed Central  PubMed  Google Scholar 

  18. Van Belle E, Rioufol G, Pouillot C, Cuisset T, Bougrini K, Teiger E et al (2014) Outcome impact of coronary revascularization strategy reclassification with fractional flow reserve at time of diagnostic angiography: insights from a large French multicenter fractional flow reserve registry. Circulation 129:173–185

    Article  PubMed  Google Scholar 

  19. Ferguson TB Jr, Chen C, Buch AN (2013) Fractional flow reserve-guided coronary bypass surgery: should surgeons use it? Curr Opin Cardiol 28:654–660

    Article  PubMed  Google Scholar 

  20. Balacumaraswami L, Abu-Omar Y, Choudhary B, Pigott D, Taggart DP (2005) A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency. J Thorac Cardiovasc Surg 130:315–320

    Article  PubMed  Google Scholar 

  21. Desai ND, Miwa S, Kodama D, Cohen G, Christakis GT, Goldman BS et al (2005) Improving the quality of coronary bypass surgery with intraoperative angiography: validation of a new technique. J Am Coll Cardiol 46:1521–1525

    Article  PubMed  Google Scholar 

  22. Desai ND, Miwa S, Kodama D, Koyama T, Cohen G, Pelletier MP et al (2007) A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts. J Thorac Cardiovasc Surg 133:592–593

    Google Scholar 

  23. Handa T, Katare RG, Sasaguri S, Sato T (2009) Preliminary experience for the evaluation of the intraoperative graft patency with real color charge-coupled device camera system: an advanced device for simultaneous capturing of color and near-infrared images during coronary artery bypass graft. Interact Cardiovasc Thorac Surg 9:150–154

    Article  PubMed  Google Scholar 

  24. Hol PK, Fosse E, Mork BE, Lundblad R, Rein KA, Lingaas PS et al (2001) Graft control by transit time flow measurement and intraoperative angiography in coronary artery bypass surgery. Heart Surg Forum 4:254–257

    CAS  PubMed  Google Scholar 

  25. Leacche M, Balaguer JM, Byrne JG (2009) Intraoperative grafts assessment. Semin Thorac Cardiovasc Surg 21:207–212

    Article  PubMed  Google Scholar 

  26. Reuthebuch O, Häussler A, Genoni M, Tavakoli R, Odavic D, Kadner A et al (2004) Novadaq SPY: intraoperative quality assessment in off-pump coronary artery bypass grafting. Chest 125:418–424

    Article  PubMed  Google Scholar 

  27. Rubens FD, Ruel M, Fremes SE (2002) A new and simplified method for coronary and graft imaging during CABG. Heart Surg Forum. 5:141–144

    PubMed  Google Scholar 

Download references

Acknowledgments

We want to acknowledge Christiane Pahrmann for her support in the animal laboratory and Günter Daum, PhD for his support in editing the manuscript.

Funding sources

The present study was supported by the Institut für Lasertechnologien in der Medizin und Messtechnik, University Ulm, and the University Heart Center Hamburg, Germany.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Christian Detter.

Ethics declarations

Conflict of interest

None.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wipper, S., Reiter, B., Russ, D. et al. Distinction of non-ischemia inducing versus ischemia inducing coronary stenosis by fluorescent cardiac imaging. Int J Cardiovasc Imaging 32, 363–371 (2016). https://doi.org/10.1007/s10554-015-0767-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-015-0767-y

Keywords

Navigation