Skip to main content
Log in

Micro Flow-through PCR in a PMMA Chip Fabricated by KrF Excimer Laser

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

As the third PCR technology, micro flow-through PCR chip can amplify DNA specifically in an exponential fashion in vitro. Nowadays many academies in the world have successfully amplified DNA using their own-made flow-through PCR chip. In this paper, the ablation principle of PMMA at 248 nm excimer laser was studied, then a PMMA based flow-through PCR chip with 20 cycles was fabricated by excimer laser at 19 kv and 18 mm/min. The chip was bonded together with another cover chip at 105C, 160N and 20 minutes. In the end, it was integrated with electrical thermal thin films and Pt100 temperature sensors. The temperature controllers was built standard PID digital temperature controller, the temperature control precision was ± 0.2C. The temperature grads between the three temperature zones were 16.5 and 22.2C respectively, the gaps between the temperature zones could realize heat insulation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • M.U. Kopp, A.J. de Mello, A. Manz, et al., Science 280, 1046(1998).

  • I. Schneegaß, R. Bräutigamb, and J. M. Köhlera, Lab on chip 1, 42 (2001).

    Article  Google Scholar 

  • J. Chiou, P. Matsudaira, Ain Sonin, et al., Anal. Chem 73, 2018(2001).

  • K. Suna, A. Yamaguchi, Y. Ishida, et al., Sensors and Actuators B84, 283(2002).

    Google Scholar 

  • Q. Zhang, W. Wang et al., Sensors and Actuators B82, 75 (2002).

    Google Scholar 

  • H. Becker and L.E. Locascio, Talanta 56, 267 (2002).

    Article  Google Scholar 

  • V. Srinivasan, M.A. Smritic, and S.V. Babu, J. Appl. Phys 59, 3860 (1986).

    Article  Google Scholar 

  • P.E.Dyer, Appl.Phys.A77, 167(2003)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Liying Yao.

Additional information

National Natural Science Foundation of China (Grant No.50175002), and Beijing (Grant No. 3031001).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yao, L., Liu, B., Chen, T. et al. Micro Flow-through PCR in a PMMA Chip Fabricated by KrF Excimer Laser. Biomed Microdevices 7, 253–257 (2005). https://doi.org/10.1007/s10544-005-3999-0

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-005-3999-0

Keywords

Navigation