Theoretical and experimental results on the influence of the antenna reflection coefficient on results of measurement of the radio brightness temperature with a miniature microwave radiometer with a circulator are presented. These studies showed that the radiothermometer with a circulator developed here, in which the reference and balance loads are mounted on a Peltier element, ensures that measurement results are independent of the antenna reflection coefficient. The radio brightness temperature measurement error was 0.2°C, with a power reflection coefficient at the radiothermometer input of 0.25.
Similar content being viewed by others
References
Goryanin, I. et al., "Passive microwave radiometry in biomedical studies," Drug Discov. Today, 25, No. 4, 757–763 (2020).
Rodrigues, D. B. et al., "Microwave radiometry for noninvasive monitoring of brain temperature," in: Emerging Electromagnetic Technologies for Brain Diseases Diagnostics, Monitoring and Therapy, Springer, Champaign (2018), pp. 87–127
Groumpas, E. I., Koutsoupidou, M., and Karanasiou, I. S., "Biomedical passive microwave imaging and sensing: current and future trends [Bioelectromagnetics]," IEEE Antennas and Propagation Magazine, 64, No. 6, 84–111 (2022).
Stauff er, P. R. et al., "Non-invasive measurement of brain temperature with microwave radiometry: Demonstration in a head phantom and clinical case," Neuroradiol. J., 27, No. 1, 3–12 (2014).
Gulyaev, Yu. V., Leushin, V. Yu., Gudkov, A. G., et al., "Instruments for the diagnosis of pathological changes in the human body using microwave radiometry," Nanotekhnol. Razrabot. Primen. XXI Vek, 9, No. 2, 27–45 (2017).
Leushin, V. Yu., Gudkov, A. G., Agasieva, S. V., et al., "Possibilities of increasing the noise immunity of radiothermograph antenna applicators for brain diagnostics," Sensors and Actuators A: Physical, 337, Article ID: 113439 (2022).
Drakopoulou, M. et al., "The role of microwave radiometry in carotid artery disease. Diagnostic and clinical prospective," Curr. Opin. Pharmacol., 39, 99–104 (2018).
Toutouzas, K. et al., "Noninvasive detection of increased carotid artery temperature in patients with coronary artery disease predicts major cardiovascular events at one year: Results from a prospective multicenter study," Atherosclerosis, 262, 25–30 (2017).
Vesnin, S., Turnbull, A. K., Dixon, J. M., and Goryanin, I., "Modern microwave thermometry for breast cancer," J. Mol. Imag. Dynam., 7, No. 2, Article ID: 1000136 (2017).
Fisher, L. et al., "Passive microwave radiometry and microrna detection for breast cancer diagnostics," Diagnostics (Basel), 13, No. 1, 118 (2023).
Laskari, K. et al., "Joint microwave radiometry for inflammatory arthritis assessment," Rheumatology, 59, No. 4, 839–844 (2020).
Tarakanov, A. V. et al., "Microwave radiometry (MWR) temperature measurement is related to symptom severity in patients with low back pain (LBP)," J. Bodyw. Mov. Ther., 26, 548–552 (2021).
Kaprin, A. D. et al., "Microwave radiometry in the diagnosis of various urological diseases," Biomed. Eng., 53, 87–91 (2019).
Arunachalam, K. et al., "Detection of vesicoureteral reflux using microwave radiometry — System characterization with tissue phantoms," IEEE Trans. Biomed. Eng., 58, No. 6, 1629–636 (2011).
Li, J. et al., "Dynamic weight agnostic neural networks and medical microwave radiometry (MWR) for breast cancer diagnostics," Diagnostics (Basel), 12, No. 9, 2037 (2022).
Losev, A. G. and Svetlov, A. V., "Artificial intelligence algorithms in diagnosis of breast cancer," in: New Technology for Inclusive and Sustainable Growth, Springer, Singapore (2022), pp. 175–182.
Gudkov, A. G. et al., "Microminiaturization of multichannel multifrequency radiographs," Biomed. Eng., 56, No. 4, 225– 229 (2022).
Cedankin, M. K., Vesnin, S. G., Agasieva, S. V., et al., "A diagnostic conformal system for neuroimaging of the brain using a multichannel radiothermometer based on monolithic integrated circuits," Nanotekhnol. Razrabot. Primen. XXI Vek, 12, No. 1, 43–50 (2020).
Momenroodaki, P. et al., "Noninvasive internal body temperature tracking with near-field microwave radiometry," IEEE Trans. Microwave Theory Techn., 66, No. 5, 2535–2545 (2017).
Vesnin, S. G. et al., "Portable microwave radiometer for wearable devices," Sensors and Actuators A: Physical, 318, Article ID 112506 (2021).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Meditsinskaya Tekhnika, Vol. 57, No. 2, March–April, 2023, pp. 8–11.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Vesnin, S.G., Sedankin, M.K., Gudkov, A.G. et al. Influence of the Coefficient of Reflectance of Antennas on Measurement Results from a Miniature Microwave Radiothermometer. Biomed Eng 57, 85–89 (2023). https://doi.org/10.1007/s10527-023-10274-y
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10527-023-10274-y