An improved optical coherence tomography system equipped with an endoscopic probe is presented. A key feature of the described device is the possibility of high-precision positioning of the endoscopic probe. This effect is achieved by the use of microelectromechanical systems for assessing the angular velocity and acceleration. The scanning process is optically synchronized with the process of calculation of the spatial coordinates of the endoscopic probe. The expediency of using the developed system for real-time evaluation of the biomechanical properties of blood vessel walls or their phantoms is discussed.
Similar content being viewed by others
References
Gora, M. J., Suter, M. J., Tearney, G. J., and Li, X. “Endoscopic optical coherence tomography: Technologies and clinical applications,” Biomed. Optics Express, 8, No. 5, 2405-2444 (2017).
Adams, D. C., Wang, Y., Hariri, L. P., and Suter, M. J., “Advances in endoscopic optical coherence tomography catheter designs,” IEEE J. Sel. Top. Quantum Electron., 22, No. 3, 210-221 (2016).
Uribe-Patarroyo, N. and Bouma, B. E., “Rotational distortion correction in endoscopic optical coherence tomography based on speckle decorrelation,” Optics Letters, 40, No. 23, 5518-5521 (2015).
Tsai, T.-H., Fujimoto, J. G., and Mashimo, H., “Endoscopic Optical Coherence Tomography for Clinical Gastroenterology,” Diagnostics (Basel), 4, No. 2, 57-93 (2014).
Walther, J., Schnabel, C., Tetschke, F., Rosenauer, T., et al., “In vivo imaging in the oral cavity by endoscopic optical coherence tomography,” J. Biomed Opt., 23, No. 7, 1-13 (2018).
Yaqoob, Z., Wu, J., McDowell, E. J., Heng, X., and Yang, C., “Methods and application areas of endoscopic optical coherence tomography,” J. Biomed. Opt., 11, No. 6, 063001 (2006).
Frolov, S. V., Potlov, A. Yu., Proskurin, S. G., and Sindeev, S. V., “An endoscopic probe for optical coherence tomography,” RF Patent for Utility Model A61M 25/00, A61B 6/00 (2006.01); RU 184084 U1; Byul. No. 29 (2018).
Liang, S., Saidi, A., Jing, J., Liu, G, et. al., “Intravascular athero-sclerotic imaging with combined fluorescence and optical coherence tomography probe based on a double-clad fiber combiner,” J. Biomed. Opt., 17, No. 7, 0705011 (2015).
Li, X., Yin, J., Hu, C., and Zhou, Q. “High-resolution coregis-tered intravascular imaging with integrated ultrasound and optical coherence tomography probe,” Appl. Phys. Lett., 97, No. 13, 133702 (2010).
Collin, J., Davidson, P., Kirkko-Jaakkola, M., and Leppäkoski, H., “Inertial sensors and their applications,” in: Handbook of Signal Processing Systems (2019), pp. 51-85.
Bojja, J., Kirkko-Jaakkola, M., Collin, J., and Takala, J., “Indoor localization methods using dead reckoning and 3D map matching,” J. Signal Proc. Syst., 76, 301-312 (2014).
Frolov, S. V., Potlov, A. Yu., and Sindeev, S. V., “Selection of flow-diverter stent models using optical coherence tomography and mathematical modeling of hemodynamics,” Med. Tekh., No. 6, 4-7 (2017).
Tsai, T.-H., Potsaid, B., Tao, Y. K., Jayaraman, V., et al., “Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology,” Biomed. Opt. Express, 4, No. 7, 1119-1132 (2013).
Pahlevaninezhad, H., Lee, A. M., Hohert, G., Lam, S., et al., “Endoscopic high resolution autofluorescence imaging and OCT of pulmonary vascular networks,” Opt. Lett., 41, No. 14, 3209-3212 (2016).
Frolov, S. V., Sindeev, S. V., Potlov, A. Yu., and Liepsch, D., “Numerical modeling of the effects of a flow-diverting stent on hemodynamic characteristics in a cerebral aneurysm,” Med. Tekh., No. 6, 1-3 (2016).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Meditsinskaya Tekhnika, Vol. 53, No. 1, Jan.-Feb., 2019, pp. 5-8.
Rights and permissions
About this article
Cite this article
Frolov, S.V., Potlov, A.Y. An Endoscopic Optical Coherence Tomography System with Improved Precision of Probe Positioning. Biomed Eng 53, 6–10 (2019). https://doi.org/10.1007/s10527-019-09866-4
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10527-019-09866-4