A method of calculating the neutron-kinetics parameters with and without the aid of the value function implemented in the MCU program code and the computational results are presented. Calculations of nineteen critical experiments from the ICSBEP Handbook were performed in order to investigate the influence of the neutron-value function on the accuracy of the calculation of the effective delayed-neutron fraction βeff and the prompt neutron generation time Λ. Analysis showed that the neutron-kinetics parameters are determined with greater precision if the value function is taken into account.
Similar content being viewed by others
References
M. A. Kalugin, D. S. Oleynik, and D. A. Shkarovsky, “Overview of the MCU Monte Carlo software package,” Ann. Nucl. Energy., 82, 54–62 (2015).
G. R. Keepin, Physical Principles of the Kinetics of Nuclear Reactors [Russian translation], Atomizdat, Moscow (1967).
M. I. Gurevich, M. A. Kalugin, D. S. Oleynik, and D. A. Shkarovsky, “Estimation of some neutron physics characteristics by Monte Carlo method using the importance function,” Ann. Nucl. Energy, 130, 388–393 (2019).
S. V. Zabrodskaya, A. V. Ignatyuk, V. N. Koshcheev, et al., “ROSFOND – Russian National Library of Neutron Data,” Vopr. At. Nauki Tekhn. Ser. Yad. Reakt., No. 1–2, 3–21 (2007).
D. S. Oleynik, “Monte Carlo calculation of weakly coupled systems,” Atomic Energy, 99, No. 4, 694–701 (2005).
F. Brown, S. Carney, B. Kiedrowski, and W. Martin, “Fission matrix capability for MCNP. Part I. Theory,” Int. Conf. Math. & Comp. Appl. Sci. Eng. (2013), pp. 15–20.
H. Paxton, “Fast critical experiments,” Progr. Nucl. Energy, 7, 151–174 (1981).
G. Hansen and H. A. Paxton, “Critical assembly of uranium enriched to 10% in Uranium-235,” Nucl. Sci. Eng., 72, No. 2, 230–236 (1979).
K. Tonoike, Y. Miyoshi, T. Kikuchi, and T. Yamamoto, “Kinetic parameter βeff/l measurement on low enriched uranyl nitrate solution with single unit cores (600 φ, 280 T, 800 φ) of STACY,” J. Nucl. Sci. Technol., 39, No. 11, 1227–1236 (2002).
K. Nakajima, “Re-evaluation of the effective delayed neutron fraction measured by the substitution technique for a light water moderated low-enriched uranium core,” J. Nucl. Sci. Technol., 38, No. 12, 1120–1125 (2001).
R. Sanchez and P. Jaegers, “Prompt neutron decay constants in SHEBA,” Trans. Am. Nucl. Soc., 76, 363–364 (1997).
G. A. Spriggs, Measurement of the effective delayed neutron fraction of the Westinghouse Idaho nuclear company Slab tank assembly using Rossi-α techniques,” Nucl. Sci. Eng., 115, 76–80 (1993).
International Handbook of Evaluated Criticality Safety Benchmark Experiments, NEA/NSC/DOC(95)03, Nuclear Energy Agency (2002).
R. Meulekamp and S. Marck, “Calculating the effective delayed neutron fraction with Monte Carlo,” Nucl. Sci. Eng., 152, 142–148 (2006).
G. I. Bell and S. Glasstone, Theory of Nuclear Reactors, Atomizdat, Moscow (1974).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Atomnaya Énergiya, Vol. 132, No. 5, pp. 259–264, May, 2022.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Gurevich, M.I., Daichenkova, Y.S., Kalugin, M.A. et al. Neutron-Value Function Influence on the Accuracy of MCU-Aided Calculations of the Effective Delayed-Neutron Fraction and Prompt-Neutron Generation Time: An Investigation. At Energy 132, 272–276 (2022). https://doi.org/10.1007/s10512-023-00940-5
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10512-023-00940-5